Filtry
wszystkich: 6
Wyniki wyszukiwania dla: EHD DEVICE
-
Pumping effect measured by PIV method in a multilayer spike electrode EHD device for air cleaning
PublikacjaDust particles can be harmful for human health when inhaled. Particularly dangerous are submicrometer dust particles, which can contain traces of toxic elements and can easily penetrate into the human respiratory system. Thus, efficient devices for the air cleaning from submicrometer dust particles are needed. Recently, Katatani and Mizuno have proposed an electrohydrody- namic (EHD) device for air cleaning for submicrometer particles....
-
Pumping effect measured by PIV method in multi-layer spike electrode EHD device for air cleaning
PublikacjaDust particles can be harmful for human health when inhaled. Especially dangerous are submicron dust particles, which can contain traces of toxic elements and can easily penetrate into human respiratory system. Thus, new devices for air cleaning are needed. In this work the flow velocity field patterns measured by Particle Image Velocimetry (PIV) method in an electrohydrodynamic (EHD) device for air cleaning are presented. The...
-
Comparison of EHD devices with parallel and in series spiked electrodes
PublikacjaIn this paper two electrohydrodynamic (EHD) devices for gas pumping and cleaning are presented. In both cases to induce an airflow in these EHD devices corona discharge was used. The discharge was generated between the spiked electrodes set parallel (the first case) or in series (the second case) and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device....
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublikacjaIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublikacjaIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
comparison of circular and rectangular narrow esps with longitudinal wire electrode
PublikacjaDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...