Filtry
wszystkich: 5450
wybranych: 405
-
Katalog
- Publikacje 3912 wyników po odfiltrowaniu
- Czasopisma 148 wyników po odfiltrowaniu
- Konferencje 16 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 356 wyników po odfiltrowaniu
- Wynalazki 10 wyników po odfiltrowaniu
- Projekty 33 wyników po odfiltrowaniu
- Laboratoria 9 wyników po odfiltrowaniu
- Zespoły Badawcze 15 wyników po odfiltrowaniu
- Aparatura Badawcza 3 wyników po odfiltrowaniu
- Kursy Online 492 wyników po odfiltrowaniu
- Wydarzenia 30 wyników po odfiltrowaniu
- Dane Badawcze 425 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: KONTROLA PROCESOWA
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=2.40, b=026.) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Chemical investigation of the Al2O3 ultra-thin films
Dane BadawczeUltra-thin layers of oluminum oxide (Al2O3) were deposited by ALD method. Atomic layer deposition provides precise thickness control down to a single atomic layer. The precursors used were trimethylaluminum (Sigma-Aldrich) and purified water. The deposition of the atomic layer was carried out at 200 °C. Samples with a thickness of 2 and 8 nm of alumina...
-
Wind speed, wind direction and solar radiation datasets; wind and solar energy resources analysis
Dane BadawczeDataset contain the results of wind speed, wind direction and solar radiation for wind and solar energy resources analysis performed in years 2008 and 2009. Application for efficiency and profitability of solar and wind power plants anaylsis and for energy generation forecasting algorithms design and anaysis. Datasets used in doctoral dissertations,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=3.3, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=6.4, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=3.3, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=3.3, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=6.4, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=6.4, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.80, b=0.25) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...