Filtry
wszystkich: 6416
-
Katalog
- Publikacje 912 wyników po odfiltrowaniu
- Czasopisma 2 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 36 wyników po odfiltrowaniu
- Projekty 9 wyników po odfiltrowaniu
- Kursy Online 12 wyników po odfiltrowaniu
- Wydarzenia 5 wyników po odfiltrowaniu
- Dane Badawcze 5439 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DISINFECTION CHAMBER
-
Engineering and Management of Space Systems (EMSS) - an international joint Master's double-degree program
PublikacjaDynamic development of the space sector of European, and especially of Polish and German economies results in a necessity for suitable Higher Education Institution graduates. The increasing digitization, distribution and networking of technical systems leads to the necessity of a degree programme teaching “the systems view” and “interdisciplinarity” methods and skills. Furthermore, it is necessary to consider the entire life cycle...
-
Physics-Based Coarse-Grained Modeling in Bio- and Nanochemistry
PublikacjaCoarse-grained approaches, in which groups of atoms are represented by single interaction sites, are very important in biological and materials sciences because they enable us to cover the size- and time-scales by several orders of magnitude larger than those available all-atom simulations, while largely keeping the details of the systems studied. The coarse-grained approaches differ by the scheme of reduction and by the origin...
-
Mercury intrusion porosimetry (MIP) results of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
Dane BadawczeMercury intrusion porosimetry (MIP) data - curves of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
-
Problemy modernizacji szpitali
PublikacjaStale dokonujący się rozwój technologii medycznych oraz postęp w możliwościach leczniczych w sposób zasadniczy wpływa na kształt szpitala. W obecnie realizowanych szpitalach maleje powierzchnia działów pielęgnacji chorych, natomiast zwiększa się powierzchnia działów diagnostyczno-zabiegowych. Skraca się średni czas pobytu pacjenta w szpitalu. Szpital staje się sprawną „maszyną” do diagnozowania, a następnie leczenia pacjenta w...
-
Czynniki kształtujące środowisko pacjenta w szpitalu
PublikacjaSzpital jest miejscem szczególnym – z założenia przebywają w nim osoby, znajdujące się w sytuacji niekomfortowej. Możliwości adaptacji w nowym środowisku u osób chorych, osłabionych lub osób z niepełnosprawnościami są znacząco obniżone, a przecież szpital należy do budynków o najbardziej skomplikowanej strukturze funkcjonalno-przestrzennej. Stan emocjonalny pacjenta w środowisku szpitalnym jest uzależniony od relacji z lekarzami...
-
Precise Identification of Different Cervical Intraepithelial Neoplasia (CIN) Stages, Using Biomedical Engineering Combined with Data Mining and Machine Learning
PublikacjaCervical cancer (CC) is one of the most common female cancers worldwide. It remains a significant global health challenge, particularly affecting women in diverse regions. The pivotal role of human papillomavirus (HPV) infection in cervical carcinogenesis underscores the critical importance of diagnostic strategies targeting both HPV infection and cervical...
-
General concept of functional safety - standarisation and sector aspects
PublikacjaRozdział poświęcono koncepcji bezpieczeństwa funkcjonalnego. Bezpieczeństwo funkcjonalne jest częścią bezpieczeństwa całkowitego zależną od odpowiedniej odpowiedzi systemów sterowania i/lub zabezpieczeń na sygnały wejściowe podczas wystąpienia stanów nienormalnych maszyny, instalacji lub obiektu podwyższonego ryzyka. Koncepcja bezpieczeństwa funkcjonalnego przedstawiona w normie IEC 51508 stanowi przykład dobrej praktyki inżynierskiej...
-
Analiza porównawcza procesów tłumienia i wygładzania fali ciśnienia w trakcie nieustalonego przepływu w rurociągach wykonanych z różnych materiałów.
PublikacjaUderzenie hydrauliczne jest uważane za jeden z najważniejszych problemów nieustalonego przepływu w przewodach, dlatego nadal stanowi obiekt badań wielu naukowców. To zagadnienie może być badane na dwóch poziomach: praktycznym i teoretycznym. W artykule zaprezentowane zostały wyniki badań doświadczalnych przeprowadzonych na stanowisku pomiarowym nieustalonego przepływu, funkcjonującym w Laboratorium Hydraulicznym Wydziału Inżynierii...
-
Funkcjonowanie zespołów napędu hydraulicznego maszyn w niskich temperaturach otoczenia
PublikacjaW pracy przedstawiono cztery warianty klasyfikacji rozruchów oziębionego napędu hydraulicznego. Pierwsza sytuacja dotyczy zagadnienia, w którym wszystkie zespoły układu napędowego wraz z olejem mają taką samą niską temperaturę podczas rozruchu. Pozostałe warianty odnoszą się do rozruchu w warunkach szoku termicznego wywołanych zasilaniem ciepłym czynnikiem roboczym oziębionych zespołów hydraulicznych. Rozruch zespołów...
-
Karol Grębowski dr inż.
OsobyKarol Grębowski (dr inż.) pracuje jako adiunkt w Katedrze Technicznych Podstaw Projektowania Architektonicznego na Wydziale Architektury Politechniki Gdańskiej. Jego badania naukowe dotyczą zjawisk szybkozmiennych zachodzących podczas drgań konstrukcji budowlanych, obiektów mostowych (trzęsienia ziemi) oraz badania w zakresie metodologii projektowania budynków stanowiących system ochrony pasywnej (SOP) odpornych na uderzenia pojazdów...
-
Impact response of two-layered grouted aggregate fibrous concretecomposite under falling mass impact
PublikacjaTwo-layered Grouted Aggregates Fibrous Concrete Composite (TGAFCC) is a new category concrete which became popular recently and attracted the attention of researchers globally. Recent studies indicated that TGAFCC has notable improvement in mechanical properties, which has been sufficiently documented. However, the impact behaviour of TGAFCC when combined with Glass Fibre Mesh (GFM) and Textile Fibre Mesh (TFM) is still unexplored....
-
Photocatalytic decomposition of acetaldehyde over TiO2 (titanium dioxide) supported on nickel foam and Ni-doped (nickel-doped) TiO2
Dane BadawczeThis dataset contains chromatograms recorded during the decomposition of acetaldehyde in a high-temperature reaction chamber under UV irradiation using as photocatalytic systems TiO2 (titanium dioxide) supported on nickel foam, TiO2 supported on oxidized nickel foam and TiO2 doped by metallic nickel (Ni) powder. The detailed equipment and measurement...
-
Smart Embedded Systems with Decisional DNA Knowledge Representation
PublikacjaEmbedded systems have been in use since the 1970s. For most of their history embedded systems were seen simply as small computers designed to accomplish one or a few dedicated functions; and they were usually working under limited resources i.e. limited computing power, limited memories, and limited energy sources. As such, embedded systems have not drawn much attention from researchers, especially from those in the artificial...
-
Architekturführer Danzig: Gdansk Sopot Gdynia
PublikacjaIm Zweiten Weltkrieg bis auf die Grundmauern zerstört, wurde der historische Stadtkern der Hansestadt Danzig als polnisches Gdańsk wiederaufgebaut – ein Paradebeispiel für kritische Rekonstruktion in Polen und zugleich eine bis heute stark umstrittene Entscheidung. Zusammen mit dem mondänen Seebad Sopot und der modernen Hafenstadt Gdynia bildet die Bernsteinstadt eine Metropolregion an der polnischen Ostseeküste: die Dreistadt...
-
Jolanta Kowal dr hab.
OsobyJolanta Kowal has a Post-doctoral Degree in Social Sciences (dr hab., DSc) in the field of economics and finance, an assistant professor, researcher, and lecturer in the Institute of Psychology of Wroclaw University, and a professor of the Gdańsk University of Technology, Poland, a Jungian analyst, an associate certified coach of International Coach Federation (ACC, ICF). Jolanta from 2014 held functions in the Board of the Polish...
-
Complete input data to CFD 3D model of combustion in the large marine 4-stroke engine
Dane BadawczeInput data to CFD and 3D model of combustion process for large marine 4-stroke diesel engine.
-
Inter Applied Chemistry Programme 1 Morrison Forensic
Kursy OnlineInter Applied Chemistry Programme 1 Lecture 1 background reading Read the following : Chapter 1 Introduction to Forensic Science ( From Jackson, Jackson, Mountain and Brealey, Forensic Science, Pearson 4th Ed (2016)) Very general professional guidance/Introduction United Nations can be found within these guides, (these are mainly for reference purposes) https://www.unodc.org/documents/scientific/Crime_scene_awareness__Ebook.pdf https://www.unodc.org/documents/justice-and-prison-reform/cjat_eng/Forensic_services_and_infrastructure.pdf Task...
-
FTIR in situ - ethylene decomposition on TiO2
Dane BadawczeThese data contain FTIR spectra recorded in FTIR spectrometer Nicolet iS50 coupled with High Temperature Chamber "The Praying Mantis". These spectra were measured for TiO2 irradiated by UV and under flowing of ethylene gas diluted in air. FTIR spectra were measured in situ during the photocatalytic process of ethylene decomposition. In order to identify...
-
A device for measuring heat flux on a rocket skin surface
PublikacjaA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
SEM micrographs and photos of salivary gland stones
Dane BadawczeThis dataset contains SEM micrographs and high-resolution photographs taken for salivary gland stones (sialolith) extracted during joint studies between Medical University of Gdansk and Gdansk University of Technology.
-
XPS data of MXene catalyst
Dane BadawczeData contain results from XPS measurement of the Ti3C2Tx MXenes produced via acidic etching aluminum from MAX Phase (Ti3C2-Al-Ti3C2-Al-Ti3C2) using 48% HF etching agent (MXene HF). The X-ray spectroscopy (XPS) measurements were conducted using Mg Ka (hn = 1253.6 eV) radiation in a Prevac (Poland) system equipped with a Scienta SES 2002 (Sweden) electron...
-
The topography of various sialoliths by scanning electron microscopy
Dane BadawczeThis dataset contains SEM micrographs taken for salivary gland stones (sialolith) extracted during joint studies between the Medical University of Gdansk and Gdansk University of Technology. Three different types of stones were examined, as discussed in the article: 10.1111/odi.13708
-
Skills Mismatch in the Context of Technological Change
PublikacjaThis dissertation examines the impact of technological change (TC) on skills and competences and how higher education’s role has changed along the way. Quantitative research was conducted to reveal the perceptions of students and employers in Poland on the relevance of particular skills in an ICT based economy. The results of this research show that there is generally a rather insignificant discrepancy in these perceptions....
-
Investigation of the uniformity of TeO2:Eu layer
Dane BadawczeTeO2 doped by Eu thin films manufactured by magnetron sputtering method were measured by XPS method. Te-Eu mosaic target with diameter of 50.8 mm was sputtered for about 45 min in argon-oxygen atmosphere what resulted in 300 nm film thickness deposition. The pressure in the deposition chamber was below 0.2 Pa and substrate was heated at 200 oC during...
-
Microscopy analysis of A549 and H460 cells' mitochondria after exposure to TXT2 and TXT4
Dane BadawczeThe data set contains live-cell imaging of A549 and H460 cells' mitochondria after exposure to TXT2 and TXT4. Cells were exposed for 6 h to the tested compounds at their IC90 concentration or to DMSO. Then, mitochondrial labelling was performed by incubating the cells with a MitoTracker Green FM probe (Thermo Fisher Scientific) and Hoechst 33342 (Thermo...
-
The experimental results of sorption cycles
Dane BadawczeExperimental studies of sorption cycles were carried out using a prototype research stand, which is a laboratory-scale model of an adsorption chiller. The Intensified Heat Transfer Adsorption Bed (IHTAB) reactor is adapted to the analysis and optimization of various parameters of adsorption systems, e.g., constructions and compositions of adsorption...
-
Optical properties of tellurium dioxide thin films
Dane BadawczeTeO2 and TeO2 doped by Eu thin films manufactured by magnetron sputtering method were measured by optical spectroscopy. Metallic Te target and Te-Eu mosaic target with diameter of 50.8 mm were sputtered for about 45 min in argon-oxygen atmosphere what resulted in 300 nm film thickness deposition. The pressure in the chamber was below 0.2 Pa and substrate...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 500 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Dane Badawcze -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....