Electrochemical investigations on the corrosion behaviour of reinforcing steel in diatomite- and zeolite-containing concrete exposed to sulphuric acid
PublicationCorrosion is a major concern for most structural applications. Its detrimental effect significantly reduces the life of metallic components. This paper presents the results of an experimental investigation of corrosion in the steel reinforcement of concrete samples having three different substituents: 20% diatomite, 20% zeolite, and a reference without zeolite or diatomite. All concrete specimens were subjected to a solution of...
Year 2014
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublicationThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Analiza weryfikująca poprawność istniejącego układu ochrony przed korozją i osadami instalacji DRW4 w kontekście obecnych warunków pracy instalacji
PublicationCelem pracy były pomiary korozyjności kondensatów pochodzących z kolumny destylacyjnej z dodatkiem neutralizatora oraz inhibitora korozji, ponadto przeprowadzono badania SEM i EDX produktów korozji pochodzących z rurek chłodnicy powietrznej. Wykazano, że znacznie większą agresywnością charakteryzują się kondensaty które pochodzą z przerobu ropy naftowej zawierającą slopy.
Year 2015
-
The protection and monitoring of a distribution piping network for potable water supply
PublicationPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
-
The Effect of Cryogenic Treatment on Microstructure and Mechanical Response of AISI D3 Tool Steel Punches
PublicationRecently, deep cryogenic treatment is performed to improve the mechanical responses (wear, hardness, fatigue, and thermal conductivity) of various steel components. Researchers have tried to evaluate the eco-friendly and nontoxic process to optimize the parameters. Cold-shearing punches used to manufacture various holes that undergo severe impact loading and wear in the metal forming process. This study concerns the effect of soaking...
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublicationThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
Year 2016
-
Wyjaśnienie przyczyn pocienienia rur w piecu technologicznym PC-1 na instalacji DRW II
PublicationWykonano analizę przyczyn korozji rur pieca instalacji DRW w oparciu o badania wizualne, SEM, EDX oraz literaturowe. W ciągu 5 lat eksploatacji nastąpiły znaczne ubytki korozyjne rur w wyniku procesów korozyjnych. Z uwagi na zbyt wysoką temperaturę rurek pieca nastąpił proces wysokotemperaturowego pylenia metalu.
-
System pomiaru szybkości korozji metodą polaryzacji liniowej w zbiorniku zatłaczającym wodę złożową oraz systemu wody morskiej na platformie wydobywczej Baltic Beta
PublicationWykonano analizę sprawności systemu monitorowania szybkości korozji na Platformie wydobywczej Baltic Beta. Dokonano niezbędnych czynności, które umożliwiły ponowne uruchomienie systemu. Przedstawiono rejestry szybkości korozji w okresie od 01.01.2015 do 24.11.2016
-
Research on causes of corrosion in the municipal water supply system
PublicationThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
Opracowanie systemu monitorowania korozji instalacji podstawowej Alkilacji HF w celu bieżącej oceny zagrożenia korozyjnego instalacji
PublicationWykonano analizę stanu zagrożenia korozyjnego instalacji alkilacji HF w PKN Orlen S.A. Wytypowano miejsca które powinny zostać objęte systemem monitorowania korozji. Zaprojektowano śluzę korozyjną. Dokonano oceny merytorycznej oraz finansowej różnych rozwiązań systemów monitorowania korozji
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublicationCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Ekspertyza stanu technicznego zbiorników wysłodzin
PublicationCelem pracy było określenie stanu technicznego czterech zbiorników wysłodzin na terenie Browaru Elbląg. Zbiorniki oddane zostały do użytku w 1984 roku i zostały wykonane ze stali niestopowej konstrukcyjnej. Ekspertyza została wykonana na podstawie badań ultradźwiękowych grubości stali zbiornika, głębokości wżerów, magnetycznym pomiarze grubości powłoki malarskiej, pomiarze potencjałów stali względem elektrody siarczano-cynkowej...
-
Effect of Thermal Shock During Legionella Bacteria Removal on the Corrosion Properties of Zinc-Coated Steel Pipes
PublicationThe purpose of this investigation was to conduct the failure analysis of a water-supply system made from zinc-coated steel. The observed corrosion process had an intense and complex character. The brownish deposits and perforations were present after 2-3 years of exploitation. The electrochemical study based on the Tafel polarization, corrosion potential monitoring, and electrochemical impedance spectroscopy together with microscopic...
-
Development Of Dynamic Method For Evaluation Of Corrosion Rate On The Example Of Organic Corrosion İnhibitor
PublicationMeasurements of the corrosion rate belong to the most important aspects of materials science. In order to reduce material loss corrosion inhibitors are used. However selection of proper inhibitor should be based on evaluation of its mechanism and effective concentrations. Mechanism of inhibition usually has dynamic character so physicochemical parameters are changing in time. Most of actually used methods...
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
Year 2017
-
Wykonanie czujnika LPR oraz dobór materiałów konstrukcyjnych w instalacji wody morskiej
PublicationWykonano analizę pracy systemu monitorowania korozji, dokonano wymiany czujnika. Zamontowano nowy czujnik z opcją pomiaru kuponowego w celu doboru materiałów konstrukcyjnych do instalacji wody morskiej.
-
Wyjaśnienie przyczyn korozji rur kotła, wytwornicy pary technologicznej instalacji Olefiny
PublicationWykonano badania przyczyn korozji rurek wytwornicy pary instalacji Olefiny. Przeprowadzono badania metalograficzne oraz SEM i EDX produktów korozji
-
Monitorowanie szybkości korozji oraz dobór materiałów konstrukcyjnych w instalacji wody morskiej platformy Baltic Beta
PublicationWykonano analizę szybkości korozji systemu monitorowania korozji z okresu od 25.11.2016 do 12.07.2017. Zdemontowano czujnik korozyjny w instalacji wody morskiej, Zainstalowani nowy czujnik z opcją pomiaru szybkości korozji metodą kuponową. Monitoringiem poddano następujące materiały: 1.7362, 1.5415, 1.0038
-
Impedancyjne monitorowanie szybkości korozji w układach wodnych z zastosowaniem inhibitorów korozji
PublicationNiniejsza praca jest poświęcona opracowaniu metodyki pomiarowej pozwalającej na wyznaczanie szybkości korozji za pomocą metody galwanodynamicznej elektrochemicznej spektroskopii impedancyjnej (GDEIS). Zaproponowana metoda pozwala na wykonywanie badań korozyjnych w których klasyczne metody pomiarowe (polaryzacja liniowa, metoda EIS, polaryzacja Tafela) charakteryzują się otrzymywaniem wyników ze znaczną dozą niepewności. W przypadku...
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublicationThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
seen 902 times