Publications
Filters
total: 805
Catalog Publications
Year 2015
-
Application of smart glasses for fast and automatic color correction in health care
PublicationIn recent years different applications of smart glasses in health care have been proposed. In this paper we present the experiments related to automatic color correction using smart glasses platform developed within the eGlasses project. The color pattern is proposed and tested enabling the automatic detection of the pattern and automatic correction of colors. Additionally, the method for encoding and decoding of patient ID in...
-
Assesment of (Mn,Co)3O4powders for possible coating material for SOFC/SOEC interconnects
PublicationIn this work (Mn,Co)3O4 spinel powders with different Mn:Co ratio (1:1 and 1:2) and from different commercial suppliers are evaluated for possible powder for production of interconnect coatings. Sinterability of the powders is evaluated on pressed pellets sintered in oxidizing and in reducing/oxidizing atmospheres. For selected powder, coatings are then prepared by the electrophoretic deposition method on Crofer 22 APU stainless...
-
Characterization of magnesium doped lanthanum orthoniobate synthesized by molten salt route
PublicationMolten salt synthesis method has been used to prepare the single phase magnesium doped lanthanum orthoniobate. The phase composition has been checked by X-ray diffraction method and the microstructure studies have been performed by scanning electron microscopy. The high temperature properties of the material have been investigated by thermogravimetry and electrochemical impedance spectroscopy. A dependence between sample total...
-
Color Processing for Color-Blind Individuals Using Smart Glasses
PublicationIn this paper we investigated image processing methods for color-blind individuals. In particular we experimentally verified color naming procedure, generation of maps with color perception differences for average observers and for dichromats, and two color transformation methods. In experiments 7 mobile devices were used: 3 smart glasses and 4 smartphones. User studies were performed with 38 average observers and 9 dichromats....
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Deposition and growth of thin ceramic films
Publication: Thin ceramic films play an important role in modern technology. One of the more utilized methods of deposition of ceramic films is spin coating. In this paper we investigate optimal deposition parameters for LaNi0.6Fe0.4O3−δ thin layers spin coated from a polymeric precursor. The quality of the obtained layers is checked using scanning electron microscopy. Additionally, we investigate the growth of grains in ceramic films annealed at...
-
Electrochemical Activity and Electrical Properties of Optimized Polypyrrole Coatings on Iron
PublicationIn this work, electrochemical activity and electrical properties of polypyrrole (PPy) coated iron electrodes have been investigated. PPy film was electrochemically polymerized from sodium salicylate aqueous solution under conditions, which provided an increase of iron corrosion resistance. It was noticed that the pH of the solution and the applied electrode potential range during the study of the polymer properties had an influence...
-
Eye tracking within near-to-eye display
PublicationIn this paper we investigate the effectiveness of the gaze interaction within near-to-eye display. The practical aspect of the paper is about combining an eye tracker with smart glasses. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of the implemented interaction methods is the one...
-
Feasibility Study for Food Intake Tasks Recognition Based on Smart Glasses
PublicationIn this exploratory study 13 adult test subjects have performed different food intake tasks while wearing a three axis accelerometer mounted at a temple of glasses. Two different algorithms for task recognition have been applied and compared. The retrospective data processing leads to better task recognition results when the frequency range of 50 Hz to 100 Hz is analysed within accelerometer signal recordings. A straightforward...
-
Fotometryczny czujnik glukozy oparty na enzymatycznych paskach testowych
PublicationCukrzyca jest chorobą dotykającą co roku na całym świecie około 3 mln ludzi [1]. Brak możliwości wyleczenia choroby generuje koszty związane z jej monitorowaniem. W USA corocznie wydaje się na ten cel 174 mld dolarów [2]. Stężenie glukozy we krwi zdrowego człowieka na czczo waha się od 80 mg/dl do 110 mg/dl [3]. Stan organizmu z niedoborem glukozy nazywany jest hipoglikemią, a stan podwyższonej zawartości cukru – hiperglikemią...
-
High temperature corrosion and corrosion protection of porous Ni22Cr alloys
PublicationIn this work corrosion kinetics of the porous IN625 alloy is studied in the temperature range of 700 °C – 800 °C in air and humidified hydrogen for up to 1000 hours. Moreover, an effective and simple method of reducing corrosion rates of porous alloys by the infiltration of the rare earths elements is shown. Modification by the yttrium containing precursor reduces the corrosion rate by a factor of 50 in air at 700 °C so that the...
-
Influence of electropolymerization conditions on the morphological and electrical properties of PEDOT film
PublicationIn this work the effects of electropolymerization conditions on the morphological properties and conductivity of poly(3,4-ethylenedioxythiophene) (PEDOT) film have been studied. PEDOT films were electrochemically synthesized in a one step process from acetonitrile solution containing 3,4-ethylenedioxythiophene (EDOT) and lithium perchlorate. Based on atomic force microscopy, scanning electron microscopy, cyclic voltammetry and...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
In-situ and ex-situ resistance measurements of polypyrrole film using double-band electrode
PublicationMany in-situ techniques are performed in order to determine the resistance of conducting polymer film. However, the resistance measured in solution can be the combination of polymer resistance and that of other components, such as resistance of supporting electrolyte. Therefore, in this work, the influence of the solution on the resistance of polypyrrole (PPy) film has been studied. PPy film was electrchemically synthesized onto...
-
Interactions using passive optical proximity detector
PublicationIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
-
Interactions with recognized patients using smart glasses
PublicationRecently, different smart glasses solutions have been proposed on the market. The rapid development of this wearable technology has led to several research projects related to applications of smart glasses in healthcare. In this paper we propose a general architecture of the system enabling data integration for the recognized person. In the proposed system smart glasses integrates data obtained for the recognized patient from health...
-
Investigation of catalytic layers on anode for solid oxide fuel cells operating with synthetic biogas
PublicationIn this paper solid oxide fuel cells operating with dry synthetic biogas have been examined. In order to increase their stability the layers of CuO-CeO2, Cu1.3Mn1.7O4 and Y0.08Sr0.92Ti0.8Fe0.2O3 -δ have been deposited on the Ni-YSZ anode site. These layers should catalyze the internal biogas reforming and prevent the carbon deposition on the anode site. It has been found that CuO-CeO2 and Cu1.3Mn1.7O4 catalysts led to an increase...
-
Investigation of thin perovskite layers between cathode and doped ceria used as buffer layer in solid oxide fuel cells
PublicationIn this paper, thin perovskite layers between cathode material of solid oxide fuel cells and gadolinia-doped ceria buffer layer are investigated. Thin layers made of LaNi0.6Fe0.4O3-δ (LNF), La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF), or SrTi0.65Fe0.35O3-δ (STF) were symmetrically deposited by spin coating method from metallo-organic polymer precursors on a Ce0.8Gd0.2O2-δ (CGO) substrate. Porous and about 40-μm-thick LNF cathodes were deposited...
-
LaNi1-xCoxO3-δ(x=0.4 to 0.7) cathodes for solid oxide fuel cells by infiltration
PublicationPerformance of LaNi 1-x Co x O 3−δ (LNC) (x=0.4 to 0.7) as a cathode in solid oxide fuel cell (SOFC) is evaluated. Symmetrical cathode/electrolyte/cathode cells for electrochemical testing are prepared by infiltration of yttria stabilized zirconia (YSZ) backbone with LNC solutions. It is showed that the cathode infiltrated with LaNi 0.5 Co 0.5 O 3−δ (LNC155) has the lowest polarization resistance and activation energy, 197 mΩ cm...
-
Local Texture Pattern Selection for Efficient Face Recognition and Tracking
PublicationThis paper describes the research aimed at finding the optimal configuration of the face recognition algorithm based on local texture descriptors (binary and ternary patterns). Since the identification module was supposed to be a part of the face tracking system developed for interactive wearable computer, proper feature selection, allowing for real-time operation, became particularly important. Our experiments showed that it is...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Lung perfusion parameters in the diagnosis of diabetic pulmonary microangiopathy
PublicationThis paper presents the role of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. In this article we focus on conditions that are necessary for such the diagnosis and introduce method of classification no microangiopathy vs. microangiopathy based on logistic regression....
-
Polypyrrole based gas sensor for ammonia detection
PublicationThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Quality of graphical markers for the needs of eyewear devices
Publicationin this paper we propose to cast the problem of identification of people, objects or places into an application for smart glasses that decodes information from graphical markers. We focus on analyzing different factors that can have influence on the processes of the automatic recognition of information from a code. The research we present aims at reviewing recognition performances in function of: size of a marker, distance from/to...
-
Septic safe interactions with smart glasses in health care
PublicationIn this paper, septic safe methods of interaction with smart glasses, due to the health care environment applications consideration, are presented. The main focus is on capabilities of an optical, proximity-based gesture sensor and eye-tracker input systems. The design of both interfaces is being adapted to the open smart glasses platform that is being developed under the eGlasses project. Preliminary results obtained from the...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublicationUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Thermal ablation modeling via the bioheat equation and its numerical treatment
PublicationThe phenomenon of thermal ablation is described by Pennes’ bioheat equation. This model is based on Newton’s law of cooling. Many approximate methods have been considered because of the importance of this issue. We propose an implicit numerical scheme which has better stability properties than other approaches.
-
Thermal Imaging in Wound Healing Diagnostics
PublicationResults of a project searching for objective, quantitative evaluation of postoperative wound healing in cardiosurgery are presented. We propose simple thermal models of the healing processes after cardiosurgery interventions as objective descriptors allowing classification of patients for extraction and following recovery at home or for prolonged treatment in a hospital. Classification of healing as the normal process or as a process...
-
Thermal Imaging in Wound Healing Diagnostics
PublicationOpisano wyniki projektu badawczego poświęconego opracowaniu metody obiektywnej diagnostyki ran pooperacyjnych w kardiochirurgii. Sprawdzono możliwość połączenia oceny obrazów RGB z obrazami termograficznymi oraz nową w medycynie metodą aktywnej termografii dynamicznej ADT. W projekcie zastosowano chłodzenie obszaru zainteresowania wykorzystując kriostat na dwutlenku węgla. W okresie powrotu do stanu równowagi termodynamicznej rejestrowane...
-
Three electrode configuration measurements of electrolyte-diffusion barrier-cathode interface
PublicationMeasurements of a system consisting of cathode/doped ceria diffusion barrier/doped zirconia electrolyte were made using two- and three-electrode configuration. Results obtained on a three-electrode measurement configuration were compared with and reflect the results obtained in two-electrode configuration. Three-electrode measurements allowed separating the impact of the symmetrical interface in the investigated system. They also...
-
Tools for Automatic Wound Healing Evaluation
PublicationFinal results of the research project devoted to development of a new objective and quantitative method of post cardiosurgery wound healing diagnostics, already preliminary discussed at the QIRT 2014 Conference, is presented. We assumed that thermal processes should be effective in subtle description of temporal changes of tissue thermal properties after surgical interventions. To prove this assumption more than 400 patients after...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublicationThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Visual Attention Distribution Based Assessment of User's Skill in Electronic Medical Record Navigation
PublicationCurrently, the most precise way of reflecting the skills level is an expert’s subjective assessment. In this paper we investigate the possibility of the use of eye tracking data for scalar quantitative and objective assessment of medical staff competency in EMR system navigation. According to the experiment conducted by Yarbus the observation process of particular features is associated with thinking. Moreover, eye tracking is...
-
Wykorzystanie monitorowania i analizy aktywności wzrokowej do oceny pracy z Systemem Informacji Szpitalnej
PublicationRozprawa doktorska przedstawia możliwość wykorzystania monitorowania i analizy aktywności wzrokowej do oceny pracy z Systemem Informacji Szpitalnej. W ramach rozprawy opracowano system do akwizycji rozkładu atencji wzrokowej w wieloekranowym środowisku. Przeprowadzono też szereg eksperymentów, które doprowadziły do opracowania współczynnika pozwalającego na określenie poziomu umiejętności osób pracujących z systemem informacji...
-
Zastosowanie metody galwanostatycznej do wyznaczania błędu fazy elektrod woltamperometrycznych
PublicationW pracy przeanalizowano właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości. Wykazano, że w przypadku, gdy reakcja elektrochemiczna kontrolowana jest procesem transportu jonów, elektroda woltamperometryczna zachowuje się tak jak przetwornik pomiarowy I rzędu. Jej właściwości metrologiczne opisane są przez czułość, częstotliwość graniczną, błąd amplitudy i błąd fazy. Przeprowadzona analiza pokazała,...
Year 2014
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A detector of sleep disorders for using at home
PublicationObstructive sleep apnea usually requires all-ni ght examination in a specialized clinic, under the supervision of a medical staff. Because of those requirements it is an expensive and a non-widely utilized test. Moving the examination procedure to patients’ home with automatic analysis algorithms involved will decrease the costs and make it available for larger group of patients. The developed device allows all-night recordings...
-
Active Dynamic Infrared Thermal Imaging in Burn Depth Evaluation
PublicationThe aim of this study was to find the relationship between active dynamic thermography (ADT) with cold excitation and burn depth. This new modality of evaluation of burns seems to be an attractive proposal for quantitative classification, allowing proper choice of burn wound treatment: conservative or surgical, especially compared with static thermography. The work was an in vivo experiment on domestic pigs, and a small number...
-
Active Dynamic Thermography imaging of wound healing processes in cardio surgery
PublicationThe surgery is a branch of medicine, that is integrally connected to wounds. Despite using sterile tools and compliance with aseptic rolls, some of the surgery wounds become infected. In clinical practice there is a lack of cheap, objective methods and tools for quantitative definition and estimation of the surgery wound healing progress. This paper presents preliminary results of Active Dynamic Thermography (ADT) parametric imaging...
-
Analiza aktywności osób z zastosowaniem czujników ruchu
PublicationArtykuł przedstawia zaprojektowany i zrealizowany system monitoringu aktywności osób z wykorzystaniem pasywnych czujników ruchu i metody generacji map aktywności. Pokazano sposób generacji map aktywności oraz wyniki uzyskane dla badań symulacyjnych i z udziałem osób
-
Analysis of activity of people using motion sensors
PublicationThe article presents the designed and implemented system for activity monitoring of people using passive motion sensors and methods for activity maps generation. In the paper he method is presented and results obtained for simulated data and for data from observations with the participation of people.
-
CeCu2O4 as a functional layer on solid oxide fuel cells for synthetic biogas reforming
PublicationSolid Oxide Fuel Cells (SOFC) are one of the most promising electrochemical devices, which can convert chemical energy to the electrical energy these days. Their ability to work with different kind of fuel makes them noteworthy. SOFC can work with biogas. The problem arises when solid carbon starts to be deposited in anode. That leads to degradation of fuel cell. Simple solution is to apply catalytic functional layer, which is...
-
Ceria Based Protective Coatings for Steel Interconnects Prepared by Spray Pyrolysis
PublicationStainless steels can be used in solid oxide fuel/electrolysis stacks as interconnects. For successful long term operation they require protective coatings, that lower the corrosion rate and block chemical reactions between the interconnect and adjacent layers of the oxygen or the hydrogen electrode. One of the promising coating materials for the hydrogen side is ceria. Using standard sintering techniques, ceria sinters at around...
-
COMPARISON OF BLOOD PRESSURE PREDICTION METHODS
PublicationIn the paper dierent approaches of predicting blood pressure values are presented. Basically, two methods and theirs modifications are considered. In total, seven algorithms have been examined. Tests have been conducted using both synthetic and clinical data. From our study it follows that none of the examined methods is superior to other.
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublicationA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
ECG-based prediction of ventricular fibrillation by means of the PCA
PublicationA Sudden Cardiac Death (SCD) is a death resulting from cardiac failure with no significant symptoms earlier than one hour before occurrence. It is the cause of for approximately 400000 deaths per year in United States and millions of deaths worldwide. The proposed system, including two-stage algorithm and wearable diagnostic device allows for SCD risk estimation and continuous monitoring of high risk patients. A single channel...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Head movement compensation algorithm in multi-display communication by gaze
PublicationAn influence of head movements on the gaze estimation accuracy when using a head mounted eye tracking system is discussed in the paper. This issue has been examined for a multi-display environment. It was found that head movement (rotation) to some extent does not influence on the gaze estimation accuracy seriously. Acceptable results were obtained when using eye-tracker to communicate with a computer via in two displays simultaneously.