Influence of water salinity on corrosion risk - the case of the southern Baltic Sea coast.
PublicationWater corrosivity in Gdansk Bay, Poland, the southern part of the Baltic Sea, was investigated. The analysed region is heavily industrialized, and the coastline is very diverse. Twenty-seven test points along the coastline were selected. Water parameters such as salinity, total dissolved solids content, resistivity, conductivity, oxygenation, pH and corrosion rate were determined. The results of the investigation are presented....
-
A new time-frequency detection method of stray current field interferenceon metal structures.
PublicationA new detection method has been presented of stray current field interference on underground metal structures. The method employs short time Fourier transformation (STFT). This method of analysis allows determination of signal spectral power density changes (e.g., structure potential) in the function of time. In the paper results have been presented of total time–frequency analysis of a pipeline potential in a stray current field...
-
The determination and identification of stray current source influences on buried pipelines using time/frequency analysis
PublicationZaprezentowano metodę detekcji źródła interferencji prądów błądzących na rurociągach podziemnych w aglomeracjach miejskich z wykorzystaniem łącznej analizy czasowo-częstotliwościowej mierzonych sygnałów. Badania przeprowadzono na rurociągu podziemnym zlokalizowanym w sąsiedztwie dwóch trakcji elektrycznych: tramwajowej i kolejowej. Wyniki analiz zaprezentowano w formie spektrogramów, które ilustrują zmiany spektralnej gęstości...
-
Method of sacrificial anode transistor-driving in cathodic protection system
PublicationA magnesium anode driving system has been proposed. A PNP driving transistor has been used. Electrochemical testing in 3%NaCl, results and comparison of the driving system and classic direct anode to cathode connection are presented. The driving system reduced the protection current and stabilized the working conditions of the anode. Higher anode efficiency was achieved. Overprotection and hydrogen embrittlement threats were prevented...
-
Potential changes in an electric field and electrolytic corrosion.
PublicationSources have been described of corrosively hazardous electric fields and methods of determination of the corrosion hazard to metal structures caused by electrolytic corrosion. Results of potential and impedance investigations in the field of stray currents flowing out of a tram traction and in the presence of a defined electric field of low frequency have been presented. Uncertainties have been indicated relating to the generally...
-
Studying the effectiveness of a modernized cathodic protection system for an offshore platform
PublicationPrzedstawiono dokonaną modernizację starego systemu ochrony katodowej nóg platformy morskiej oraz omówiono wykonane badania skuteczności przeciwkorozyjnej zastosowanego rozwiązania. Modernizacja polegała na podłączeniu do nóg platformy układów anod galwanicznych umieszczonych na dnie morza. Skuteczność działania systemu oceniono na podstawie pomiarów profili potencjałowych nóg platformy. Po podłączaniu kolejnych układów anod...
-
Study of the formation of calcareous deposits on cathodically protected steel in Baltic sea water
PublicationPurpose – The purpose of this paper is to investigate whether the sedimentation of calcareous deposits occurs on cathodically protected steel in Baltic sea water. Design/methodology/approach – Steel electrodes were cathodically polarized in natural Baltic sea water at potential þ0.150 V vs Zn electrode in potentiostatic mode. During exposure chronoamperometric measurements were carried out. After the exposure, the electrode’s surface...
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublicationCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Method of sacrificial anode dual transistor-driving in stray current field
PublicationIn order to control a magnesium anode in a stray current interference field, a dual transistor driving system has been proposed. It consisted of a combination of PNP and NPN transistors. Dual transistor driven system and direct anode to cathode connection were electrochemically tested in 3% NaCl solution. The dual transistor driven system increased the anode efficiency and reduced hydrogen evolution and the risk of embrittlement....
-
Modernized cathodic protection system for legs of the production rig – Evaluation during ten years of service
PublicationThe modernization of cathodic protection system of the Baltic Beta platform legs is described. It was that the sacrificial anodes cone-shaped groups were to be placed on the seabed at a depth of 80 m. The measurements results of cathodic protection effectiveness during its ten-years operation are presented. The effectiveness was assessed based on the potential value along the entire length of the legs from the sea surface to the...
-
Detection and time/frequency analysis of electric fields in the ground
PublicationThis paper sets out to detect and characterize electric fields in the ground (such as stray current fields) using a tandem time/frequency method of signal analysis. Results were obtained from investigations performed in the presence of a generated electric field with controlled variable characteristics, and in the presence of an electric field generated by a tramline. The analysis of measurement registers was performed using Short‐Time...
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Actual field corrosion rate of offshore structures in the Baltic Sea along depth profile from water surface to sea bed
PublicationThe paper presents the results of field electrochemical investigations on the corrosion rate of carbon steel in seawater of the Baltic Sea at the location of the Baltic Beta production rig. The measurements were conducted throughout the year in seawater at different depths from the sea surface to the sea bed (about 75 m). The results revealed corrosion aggressiveness of the seawater along the entire depth profile. There was...
-
Research on causes of corrosion in the municipal water supply system
PublicationThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublicationTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...
-
Protection of bridges against stray current corrosion
PublicationA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
The Effect of Increasing the Amount of Indium Alloying Material on the Efficiency of Sacrificial Aluminium Anodes
PublicationAl-Zn-In alloys having 4.2% zinc content and various indium content in the range of 0.02–0.2% were tested with respect to the most important electrochemical properties of sacrificial anodes in a cathodic protection, i.e., the current capacity and potential of the operating anode. The distribution of In and Zn in the tested alloys was mapped by means of the EDX technique, which demonstrated that these elements dissolve well in the...
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Increasing efficiency of technological process by limiting impact of corrosive environment on operation of spiral classifiers
PublicationMost of the technological operations related to the preparation of the output to be enriched and to the production of the final copper concentrate take place with the use of water environment. Water management, besides using innovative technical and technological solutions, is a significant factor in the whole copper ore enrichment process. Mine water resources and surface water of the tailing pond named "Żelazny Most" are the...