Year 2022
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
QRS Morphology-Based EDR Signal—Factors Determining its Properties
PublicationRespiration-induced signals contain a clinically significant information. It could be obtained utilizing both direct and indirect methods. ECG-Derived Respiration (EDR) method is the latter one. However, in this case, two approaches could be distinguished. First one is based on determining changes in the morphology of QRS complexes while the second one is based on the Respiratory Sinus Arrhythmia (RSA) mechanism. The former approach...
Year 2019
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Optimal ECG lead for deriving respiratory signal
PublicationEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
Respiratory signal of bathing person - preliminary study
PublicationThe scope of this paper is analysis of applicability of modern biomedical acquisition system installed in bathtub towards reception of respiratory signals of bathing person. An analysis of the possibility of such measurement is shown as well as preliminary results.
-
Systemy automatycznej detekcji bezdechu sennego
PublicationZgodnie z przyjętą klasyfikacją międzynarodową identyfikowanych jest ponad 60 różnych zaburzeń snu [58] z podziałem na 7 kategorii. Bezdech senny, zarówno centralny jak i obturacyjny zaliczany jest do kategorii drugiej. Systemy pomiarowe wykorzystywane w monitorowaniu i diagnozie snu, w tym wykorzystywane do detekcji bezdechu sennego, można sklasyfikować ze względu na wiele kryteriów, np. ze względu na to czy badania wykonywane...
Year 2018
-
A Biofeedback System that Uses the Game to Study Electrical Muscle Activity
PublicationThe aim of this project was to design a system that will allow performing repetitive muscle exercises using a biofeedback device. It is supposed to enhance the motivation and attractiveness of the performed tasks thanks to an interactive game developed for mobile devices with the Android operating system. The built-in calibration mechanisms enable the users to play a game that is independent of their abilities which evens out the...
-
ReFlexeNN - the Wearable EMG Interface with Neural Network Based Gesture Classification
PublicationThe electromyographic activity of muscles was measured using a wireless biofeedback device. The aim of the study was to examine the possibility of creating an automatic muscle tension classifier. Several measurement series were conducted and the participant performed simple physical exercises - forcing the muscle to increase its activity accordingly to the selected scale. A small wireless device was attached to the electrodes placed...
-
Smart Weighing Scale with Feet-Sampled ECG
PublicationIn a smart home, health and well-being monitoring systems could be embedded in everyday devices providing a pervasive care. A home bathroom scale is an example of such a device, typically used to measure body weight and very often its composition (e.g. body water/fat percentage). In this paper, we analyzed a potential use of the bathroom scale to measure electrocardiogram (ECG) from electrodes located on the scale's tile. In particular...
Year 2017
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
The role of EMG module in hybrid interface of prosthetic arm
PublicationNearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In...
Year 2016
-
Cardiovascular data analysis using electronic wearable eyeglasses-preliminary study
Publicationhe paper presents an alternative approach to the monitoring of the cardiovascular system. The study depicts configurations of the utilized system and preliminary results of electrical and mechanical parameters of the cardiac system which can be measured using a head-worn device.
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
Self diagnostics using smart glasses - preliminary study
Publicationn this preliminary study we analyzed the possibility of the reliable measurement of biomedical signals with some potential hardware extensions of smart glasses. Using specially designed experimental prototypes four category of biomedical signals were measured: electrocardiograms, electromyograms, electroencephalograms and respiration waveforms. Experi- ments with volunteers proved that using even simple construc- tion of sensors...
-
Urządzenia nasobne do monitorowania układu sercowo-naczyniowego
PublicationChoroby układu sercowo-naczyniowego są najczęstszą przyczyną zgonów na świecie. Rozszerzenie tradycyjnych metod diagnostyki i monitorowania pacjentów (EKG, Holter EKG) o dodatkowe biosygnały, oraz zastosowanie zaawansowanych metod analizy zarejestrowanych danych pozwoli na wczesną reakcję na wystąpienie epizodów zagrażających zdrowiu lub życiu pacjenta. W poniższej pracy zaprezentowano dwa urządzenia nasobne do monitorowania systemu...
-
Urządzenia nasobne do monitorowania układu sercowo-naczyniowego
PublicationChoroby układu sercowo-naczyniowego są najczęstszą przyczyną zgonów na świecie. Rozszerzenie tradycyjnych metod diagnostyki i monitorowania pacjentów (EKG, Holter EKG) o dodatkowe biosygnały, oraz zastosowanie zaawansowanych metod analizy zarejestrowanych danych pozwoli na wczesną reakcję na wystapienie epizodów zagrażających zdrowiu lub życiu pacjenta. W poniższej pracy zaprezentowano dwa urządzenia nasobne do monitorowania systemu...
Year 2015
-
Active and Dynamic Graphical Code for Object Identification in Healthcare
PublicationA new approach for item marking using two dimensional discrete graphics markers. Proposed solution allow o change the code rapidly, upon request and in the case of thermal markers make the code invisible for unauthorized observers. Connecting the proposed codes with wearable multmedial platform such as eGlasses can create new possibilities in human-environment interaction.
Year 2014
-
A detector of sleep disorders for using at home
PublicationObstructive sleep apnea usually requires all-ni ght examination in a specialized clinic, under the supervision of a medical staff. Because of those requirements it is an expensive and a non-widely utilized test. Moving the examination procedure to patients’ home with automatic analysis algorithms involved will decrease the costs and make it available for larger group of patients. The developed device allows all-night recordings...
-
ECG-based prediction of ventricular fibrillation by means of the PCA
PublicationA Sudden Cardiac Death (SCD) is a death resulting from cardiac failure with no significant symptoms earlier than one hour before occurrence. It is the cause of for approximately 400000 deaths per year in United States and millions of deaths worldwide. The proposed system, including two-stage algorithm and wearable diagnostic device allows for SCD risk estimation and continuous monitoring of high risk patients. A single channel...
-
Sleep Apnea Detection by Means of Analyzing Electrocardiographic Signal
PublicationObstructive sleep apnea (OSA) is a condition of cyclic, periodic ob-struction (stenosis) of the upper respiratory tract. OSA could be associated with serious cardiovascular problems, such as hypertension, arrhythmias, hearth failure or peripheral vascular disease. Understanding the way of connection between OSA and cardiovascular diseases is important to choose proper treatment strategy. In this paper, we present a method for integrated...
Year 2013
-
A multisensor detector of a sleep apnea for using at home
PublicationDiagnosis of obstructive sleep apnea usually involves polysomnographic analysis, which unfortunately requires overnight stay in a specialized clinic and is very uncomfortable for a patient. This paper describes the method and apparatus for recording a set of signals to detect sleep apnea. The device records the following signals simultaneously: three-channel ECG, respiratory functions, signals from the accelerometer, and snoring...
-
PROJEKT I IMPLEMENTACJA WIELOKANAŁOWEGO DETEKTORA BEZDECHU SENNEGO
PublicationDiagnostyka obturacyjnego bezdechu senne-go opiera się na szczegółowym wywiadzie medycznym i badaniu polisomnograficznym. Jest ono drogie i mało kom-fortowe dla pacjenta. Opisywane urządzenie pozwala na przeniesienie procesu diagnostycznego ze specjalistycznych klinik do domu pacjenta. Całonocna rejestracja szeregu biosygnałów pozwoli na automatyczną detekcję obturacyj-nego bezdechu sennego
-
Reflektancyjny pulsoksymetr mocowany na klatce piersiowej
PublicationPulsoksymetria to nieinwazyjna i nowoczesna metoda badania wysycenia krwi tlenem oraz pulsu. Istnieją dwie metody pomiaru: transmisyjna i reflektacyjna, różniące się wzajemnym położeniem źródła światła i fotodetektora. Niniejszy artykuł przedstawia pierwszą fazę projektu reflektancyjnego pulsoksymetru mocowanego na klatce piersiowej.
-
Wpływ konfiguracji elektrod pomiarowych oraz parametrów pomiaru na EDR
PublicationW pracy przebadano wplyw wybranych konfiguracji elektrod na jakość uzyskiwanego sygnału EDR. Analizie poddane zostały również częstotliwość próbkowania sygnału EKG i rozdzielczość przetwornika AC/DC. Optymalną konfiguracją elektrod jest odprowadzenie kończynowe pierwsze. Minimalne parametry układu pomiarowego do uzyskania wysokiej jakości sygnału EDR, to częstotliwość probkowania 2,5kHz oraz 14-bitowy przetwornik AC-DC.
Year 2012
-
DETEKTOR BEZDECHU SENNEGO DO UŻYTKU DOMOWEGO
PublicationDiagnostyka obturacyjnego bezdechu sennego zazwyczaj polega na analizie całonocnego badania polisomnograficznego, które wymaga niestety całonocnego pobytu w specjalistycznej klinice i jest mało komfortowe dla pacjenta. Urządzenie opisane w niniejszym dokumencie umoŜliwia całonocną rejestrację trzech kanałów czynności elektrycznej serca (EKG), funkcji oddechu, sygnału z akcelerometru oraz odgłosów chrapania. Pomiar moŜe odbywać...