Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 3140
-
Catalog
displaying 1000 best results Help
Search results for: overhead power lines
-
Structural reliability of overhead power lines by means of Monte Carlo Method and RSM
PublicationThe article discusses the issue of reliability assessment of overhead power lines by means of both Monte Carlo Method and Response Surface Method. The suspension tower OS24 ON150+10 is considered, as the weakest element of the line. A comparison is made between deterministic and probabilistic approaches to wind and icing loading. The PDFs for wind and icing loads are proposed. Reliability is assessed for both critical atmospheric...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Structural Health Monitoring of Overhead Power Transmission Lines
PublicationStructural Health Monitoring (SHM) is a novel and continuously developing branch of science and technology that draws attention of scientists all over the world. It creates opportunities to detect, localize and identify structural damage of various types such as: line breakage, permissible sag, bolt loosening, fatigue cracking or insulator contamination. On the other hand the methods used to estimate the remaining operational...
-
Impulse Measurements of Tower Earthings of Overhead Transmission Lines
PublicationPrzepisy wymagają okresowego badania uziemień słupów elektroenergetycznych linii przesyłowych. pomiary takie metodami klasycznymi niskiej częstotliwości wymagają odłączania uziomów od konstrukcji słupa, co wiąże się z wyłączaniem linii. wykorzstanie metody udarowej do oceny uziemień nie wymaga odłączania uziomów i może byc przeprowadzane podczas pracy linii.
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublicationThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublicationHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Application of 3D graphic software and GIS in visual impact assessment of high-voltage overhead transmission lines
Publication -
Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System
PublicationOverhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as cracking and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping,...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...