displaying 1000 best results Help
Search results for: AIR ENTRY PRESSURE
-
Upscaling unsaturated flow in binary porous media with air entry pressure effects
PublicationArtykuł dotyczy przepływu w gruntach nienasyconych, zawierających soczewki (inkluzje) materiału gruboziarnistego. Materiał inkluzji charakteryzuje się niższą wartością ciśnienia wejścia powietrza niż materiał tła. Podczas infiltracji część powietrza zostaje zamknięta w inkluzjach, po całkowitym wypełnieniu wodą materiału tła. Z drugiej strony, drenaż inkluzji rozpoczyna się dopiero wtedy, gdy przekroczone zostanie ciśnienie wejścia...
-
Influence of heterogeneous air entry pressure on large scale unsaturated flow in porous media
PublicationThe paper presents numerical simulations of water infiltration in unsaturated porous media containing coarse-textured inclusions embed- ded in fine-textured background material. The calculations are performed using the two-phase model for water and air flow and a simplified model known as the Richards equation. It is shown that the Richards equation cannot correctly describe flow in the presence of heterogeneities. How- ever, its...
-
Self-ignition of hydrogen–nitrogen mixtures during high-pressure release into air
Publication -
Nanoporous TiO2 electrode grown by laser ablation of titanium in air at atmospheric pressure and room temperature
PublicationRecently, fabrication of the nanoporous TiO2 photoelectrode on metal foils by means of sputtering of the Ti film on preheatedmetal substrate followed by the TiO2 deposition (doctor blade technique) and sintering represents the frequently applied technique. This is despite the relatively complicated procedure and number of parameters to be controlled in order to fabricate films of required properties. In this work an approach is...
-
Experimental and comparative study on the two-phase pressure drop of air-water mixture in U-bend and straight pipe annuli
PublicationIn this paper, the experimental and theoretical analysis of pressure drop in singlephase and two phase-flow were presented for straight and U-bend smooth tube annulus and tube annulus with wire coil insert. Experiments for various boundary conditions were performed. In case of U-tube and straight tube with and without turbulator, tests were made for the water-water and air-water systems. The study covered a wide measuring range,...
-
Relationship between heart rate variability, blood pressure and arterial wall properties during air and oxygen breathing in healthy subjects
PublicationPrevious studies reported that normobaric hyperoxia influences heart rate, arterial pressure, cardiac output and systemic vascular resistance, but the mechanisms underlying these changes are still not fully understood. Several factors are considered including degeneration of endothelium-derived nitric oxide by reactive oxygen species, the impact of oxygen-free radicals on tissues and alterations of autonomic nervous system function....
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=7.3, b=0.49) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=6.4, b=0.45) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=6.2, b=0.38) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=3.3, b=0.40) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=4.4, b=0.42) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=5.3, b=0.38) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a pneumatic hose from changes in air pressure in a tank being emptied or filled by a differently configured pneumatic line
Open Research DataThe aim of the study was to determine the flow properties of various pneumatic hoses. The experiments were to measure the pressure changes in a being filled or emptied tank for a differently configured pneumatic line, including pneumatic hoses of different length and diameter. Three test configurations were used: (1) pressure source -> pneumatic...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...