Filters
total: 39
Search results for: DLC
-
Wear of Ultra-thin DLC or Tungsten-modified DLC Coatings under Reciprocating Sliding
PublicationIn the paper results are presented from tests in reciprocating sliding of self mated specimens of DLC and tungsten modified DLC coatings on stainless steel substrate. The contact geometry chosen for the research task was ball on flat. The contacts were lubricated either with distilled water or medical saline solution. Results are presented with regard to wear resistance as a function of material type and lubricant used.
-
Friction and wear behaviour of self mated DLC and DLC-W coatings in water or salt in water solution lubricated sliding
PublicationPrzedstawiono wyniki badań powłok ceramicznych DLC oraz DLC z wolframem (DLC-W) nałożonych na podłoże ze stali nierdzewnej,przy tarciu ślizgowym , w modelowym skojarzeniu o styku konforemnym (płaskie czoło obracającej się względem swojej osi tulei - powierzchnia płaska). Badania prowadzono stosując smarowanie wodą destylowaną albo wodnym roztworem soli - NaCl. Wyznaczano współczynniki tarcia oraz intensywność zużywania ceramicznej...
-
WEAR TESTING OF DLC COATINGS WITH FRICTION COUPLE „BALL-ON-DISK” = Badania zużycia powłok DLC w skojarzeniu kula-tarcza obrotowa ''ball-on-disk''
PublicationW Katedrze Konstrukcji i Eksploatacji Maszyn PG opracowano metodę badania powłok DLC oraz innych (ceramicznych) w układzie kula - płaska powierzchnia obrotowej tarczy ("ball-on-disk"). Układ badawczy składa się z kuli osadzonej w popychaczu łożyskowanym tocznie, poprzez który wywierana jest siła docisku próbek. Kula dociskana jest od góry do płaskiej powierzchni obrotowej tarczy - próbki dolnej (o pionowej osi obrotu). Próbka dolna...
-
Optoelectronic system for investigation of cvd diamond/DLC layers growth
PublicationDevelopment of the optoelectronic system for non-invasive monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during μPA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The system uses multi-point Optical Emission Spectroscopy (OES) and long-working-distance Raman spectroscopy. Dissociation of H2 molecules, excitation and ionization of hydrogen atoms...
-
EXPERIMENTAL EVALUATION OF DLC/STEEL SLIDING CONTACTS’ OPERATIONAL ENVELOPE
PublicationIn an industrial project concerning sliding bearings, a sliding pair was selected of high alloy steel vs. industrial grade DLC coated high alloy steel as a basis for an innovative design of high performance sliding bearings lubricated with a synthetic oil for use in geared transmission units. The development process required credible data on the ultimate resistance of the sliding pair to very high contact stress. An experimental...
-
Scuffing resistance of DLC-coated gears lubricated with ecological oil
Publication -
Impact of Plasma Pre-Treatment on the Tribological Properties of DLC Coatings on PDMS Substrates
Publication -
The Effect of a Gear Oil on Abrasion, Scuffing, and Pitting of the DLC-Coated 18CrNiMo7-6 Steel
Publication -
Long-working-distance Raman system for monitoring of uPA ECR CVD process of thin diamond/DLC layers growth
PublicationW artykule przedstawiono konstrucję systemu optoelektronicznego do monitoringu ramanowskiego in-situ procesu μPA ECR CVD (ang.: Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition), stosowanego do osadzania cienkich warstw diamentowych i diamentopodobnych DLC. System ma budowę modułową i wyposażony jest w dedykowane sondy optyczne. Przedstawiono wyniki pomiarów testowych, potwierdzjące, że system posiada...
-
Ocena odporności powłok na bazie DLC na doraźne uszkodzenie w warunkach tarcia ślizgowego ze smarowaniem wodą i solą fizjologiczną = Evaluation of DLC based coatings resistance to instanteneous damage under sliding friction conditions with distilated water or saline lubrication
PublicationWykonano serię testów w celu wyznaczenia granicznych warunków wymuszenia, zdefiniowaego jako średnie naciski powierzchniowe oraz prędkość ślizgania, po przekroczeniu których następuje gwałtowne zniszczenie powłoki. Na podstawie wyników pomiarów opracowano aproksymowane charakterystyki granicznych wymuszeń w układzie p - v oraz pokrewnych dla badanych materiałów, smarów i zakresu parametrów wymuszenia.
-
Abrasive Wear, Scuffing and Rolling Contact Fatigue of DLC-Coated 18CrNiMo7-6 Steel Lubricated by a Pure and Contaminated Gear Oil
Publication -
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
Deposition, morphology and functional properties of layers based on DLC:Si and DLC:N on polyurethane
Publication -
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Preparation and Characterization of Diamond-like Carbon Coatings for Biomedical Applications—A Review
PublicationDiamond-like carbon (DLC) films are generally used in biomedical applications, mainly because of their tribological and chemical properties that prevent the release of substrate ions, extend the life cycle of the material, and promote cell growth. The unique properties of the coating depend on the ratio of the sp3/sp2 phases, where the sp2 phase provides coatings with a low coefficient of friction and good electrical conductivity,...
-
Experimental study on the feasibility of alternative materials for tilting pad thrust bearings operating in transition to mixed friction
PublicationIn hydrodynamic bearings traditional bearing alloys: Babbitts and bronzes are most frequently utilized. Polymer sliding layers are sometimes applied as a valuable alternative. Hard diamond-like carbon (DLC) coatings, which are also considered for certain applications may show some advantages, as well. Although material selection is of secondary importance in a full film lubrication regime it becomes important in mixed friction...
-
Optoelectronic system for monitoring of thin diamond layers growth
PublicationDevelopment of the optoelectronic system for monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during mu PA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The multi-point Optical Emission Spectroscopy (OES) and Raman spectroscopy were employed as non-invasive optoelectronic tools. Dissociation of H-2 molecules, excitation and ionization of hydrogen...
-
WEAR OF Si OR B DOPED AMORPHOUS CARBON COATINGS
PublicationThe paper describes a complex wear research on DLC (amorphous carbon) moped with boron (B) and silicone (Si). The tests were carried out in two different sliping systems: flat–on–flat (ring contact, unidirectional sliding) and ball–on–flat (reciprocating sliding). Water and medical saline solutions were used as lubricants. A comparative analysis of the results revealed differences in the initiation and progress of wear and the...
-
System optoelektroniczny do kontroli procesów μPA CVD
PublicationPrzedstawiono prototyp optoelektronicznego systemu do monitorowania in-situ procesu CVD, wspomaganych plazmą mikrofalową. System składa się z układu optycznej spektroskopii emisyjnej OES oraz specjalizowanego spektroskopu ramanowskiego RS. Umożliwia on równoczesne monitorowanie składu plazmy oraz określanie dynamiki wzrostu i zawartości defektów warstwy. Przedstawiono wyniki badań przebiegu procesu wytwarzania warstw diamentopodobnych...
-
Synteza warstw diamentowych do zastosowań optoelektronicznych
PublicationDiamenty stosowane w optoelektronice i sensoryce syntetyzowane są w próżni przy użyciu plazmy niskotemperaturowej. Nanostruktury powstają przez wzrost struktur z molekuł, a nawet atomów. Wytwarzanie nanostruktur wymaga precyzyjnego monitoringu procesu syntezy. Optoelektroniczne metody pomiarowe zapewniają kontrolę wzrostu warstw oraz ocenę in situ parametrów materiałowych. W artykule przedstawiono optoelektroniczne metody badania...
-
Optoelektroniczny system przestrzennego monitoringu wzbudzenia plazmy w procesach syntezy optycznych warstw diamentopodobnych
PublicationPrzedmiotem pracy jest optoelektroniczny system do badania wzbudzenia plazmy mikrofalowej w procesie syntezy warstw DLC (ang. Diamond Like-Carbon). W komunikacie zaprezentowano budowę systemu do przestrzennego monitoringu stanu wzbudzenia plazmy podczas procesu CVD. System SR-OES (ang. Spatially Resolved Optical Emission Spectroscopy) umożliwia określanie rozkładu wzbudzenia cząstek w przestrzeni komory i na tej podstawie wybrania...
-
Monitoring ramanowski wzrostu cienkich warstw węglowych-studium
PublicationPrzedstawiono zagadnienia monitorowania in-situ prózniowego procesu wzrostu cienkich warstw węglowych, a w szczególności diamentowych i diamentopodobnych DLC. Zastosowanie pomiarów ramanowskich umożliwia zbadanie struktury warstwy na poziomie molekularnych (zawartości faz węglowych sp2 i sp3, a także defektów wodorowych). Użycie spektroskopii in-situ podczas procesu syntezy pozwala monotorować poprawność przebiegu procesu i opracować...
-
Optoelektroniczny monitoring stanu wzbudzenia plazmy niskotemperaturowej w procesach syntezy optycznych warstw diamentopodobnych
PublicationZrealizowana praca jest jednym z głównych zadań wieloletniego projektu badawczego z zakresu syntezy warstw diamentopodobnych. Celem bezpośrednim pracy było określenie rozkładu wzbudzenia plazmy w komorze technologicznej stanowiska PA ECR CVD. Głównym celem było opracowanie optoelektronicznego systemu pomiarowego, na którego potrzeby zastosowano przestrzennie selektywną optyczną spektroskopię emisyjną dedykowaną do badania procesu...
-
Considerations of Adaptive Digital Communications in Underwater Acoustic Channel
PublicationDown-link communication (DLC) and air transportable communication (ATAC) buoys as well as autonomous underwater vehicles (AUV) use acoustic links for gathering oceanographic data from underwater monitoring systems. The underwater channel propagation conditions are diverse in nature and require a special adaptive approach to the communication system design. The article presents a methodology for the communication systems design,...
-
A Multi Rig Screening Test for Thin Ceramic Coatings in Bio - Tribological Applications
PublicationA method is presented for the comparative testing of wear resistance of ceramic coatings made from materials potentially feasible in tribo - medical applications, mainly orthopaedic implants made from ceramics coated metals for low cost, long life and low wear particle emission into the body. The method was devised as the main tool for use in research and is comprised of flat on flat and ball on flat surface (sliding) tests. Seven...
-
Badania uszkodzeń powłok ceramicznych wskutek tarcia ślizgowego w ruchu postępowo-zwrotnym = Wear pattern testing of ceramic coatings under reciprocating sliding
PublicationBadano (wykorzystując mikroskop optyczny oraz skaningowy) morfologię uszkodzeń wybranych powłok ceramicznych ( m.in. DLC z dodatkiem wolframu) nakładanych na podłoże stalowe, będących skutkiem tarcia slizgowego w ruchu postępowo-zwrotnym skojarzenia kula-powierzchnia płaska. Ślady zużycia na kulach, czyli obszary wygładzonych plateau, mają kształt zbliżony do elipsy. Praca, przy zmiennym zwrocie sił stycznych działających na powierzchnię...
-
Centrally Pivoted Tilting Pad Thrust Bearing with Carbon-Based Coated Collar—Experimental Results of Low- and Medium-Speed Operation
PublicationExperimental results of the research on a tilting pad thrust bearing with symmetrical pad support in the conditions of high loads and low speeds are presented in the paper. As described in the literature review, experimental results of tilting pad bearings at low speed/high load regime and transient conditions are rare. Unusual material selection - steel pad against a DLC-type coating on the collar was utilized. Such material combination...
-
Wpływ równości nawierzchni i dynamicznego oddziaływania pojazdów ciężkich na trwałość zmęczeniową nawierzchni podatnych
PublicationPodczas ruchu pojazdu obserwuje się odchylenia nacisków osi pojazdów od nacisku statycznego, co jest spowodowane nierównościami nawierzchni. Dynamiczne obciążenia pojazdów w większym stopniu wytężają konstrukcję nawierzchni drogowej. Rozkład obciążeń dynamicznych ma kształt rozkładu normalnego i jest opisywany poprzez obciążenie statyczne oraz wskaźniki dynamiczne DI lub DLC. Wraz z pogorszeniem równości i zwiększeniem prędkości...
-
Self-assembly, stability and conductance of amphotericin B channels: bridging the gap between structure and function
PublicationAmphotericin B (AmB), one of the most powerful but also toxic drugs used to treat systemic mycoses, is believed to selectively permeabilize fungal cell membranes to ions in a sterol-dependent manner. Unfortunately, the structure of the biologically active AmB channels has long eluded researchers, obstructing the design of safer alternatives. Here, we investigate the structural and thermodynamic aspects of channel formation, stability,...
-
Effect of pavement roughness and vehicle dynamic loads on decrease of fatigue life of flexible pavements
PublicationDue to the fact that pavement surfaces are not ideally even, dynamic loads of vehicle axles deviate from static loads. Higher dynamic loads contribute to faster pavement distress. The distribution of dynamic loads is similar to normal distribution and can be described by static load and factors DI (dynamic impact) and DLC (dynamic load coefficient). With the deterioration of pavement condition its evenness decreases as well and...
-
Wpływ równości nawierzchni podatnej na ich trwałość
PublicationNierówności nawierzchni powodują odchylenia nacisków osi pojazdów będących w ruchu od nacisku statycznego. Dynamiczne obciążenia pojazdów w większym stopniu wytężają konstrukcję nawierzchni drogowej. Rozkład obciążeń dynamicznych ma kształt rozkładu normalnego i jest opisywany poprzez obciążenie statyczne oraz wskaźniki dynamiczne DI lub DLC. Wraz z pogorszeniem równości i zwiększeniem prędkości średniej pojazdów rosną maksymalne...
-
Innowacyjna powłoka poprawiająca własności mechaniczne oraz biokompatybilne stopów tytanu Ti6Al4V i Ti13Zr13Nb przeznaczonych na implanty wewnetrzne
PublicationOstatnie badania nad materiałami tytanowymi przeznaczonymi na implanty wewnętrzne pokazują iż dotychczas uznawany za bezinwazyjny tytan odkłada się w organizmie. Nie wiadomo jeszcze jakie konsekwencje są tego procesu dla organizmu żywego. W artykule przedstawiono idee wytworzenia nowej, biokompatybilnej powłoki, która ma na celu zminimalizowanie przenikania jonów metalu do organizmu ludzkiego oraz ułatwienie porastania implantu...
-
Ocena możliwości zastosowania obróbki laserowej i implantacji jonowej stopów metali na implant stawu kolanowego
PublicationZagadnieniem podjętym w niniejszym referacie jest zmodyfikowanie warstwy wierzchniej stopu tytanu Ti6Al4V przeznaczonego na implanty. Autor opisuje metody modyfikacji powierzchni w wyniki nakładania warstwy węglowej metodą PA CVD (ang. Plasma Assisted Chemical Vapour Deposition) oraz warstwy hydroksyapatytu metodą zol-żel i elektrochemiczną. Badania zostały przeprowadzone w laboratoriach Zakładu Biomateriałów, Katedry Inżynierii...