Search results for: EARTHING MEASUREMENT
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublicationThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
OCENA UZIEMIEŃ SŁUPÓW LINII ELEKTROENERGETYCZNYCH ZWŁASZCZA POSADOWIONYCH NA GRUNTACH O WYSOKIEJ REZYSTYWNOŚCI
PublicationW artykule została omówiona problematyka pomiaru i oceny właściwości uziemień słupów linii elektroenergetycznych z wykorzystaniem przebiegów wolno-i szybkozmiennych. Uzyskanie odpowiednio niskiej wartości rezystancji uziemienia słupa posadowionego na gruncie o rezystywności powyżej 1000Ωm może być trudne. Praca zawiera analizę zmian właściwości statycznych i udarowych uziemień w funkcji rezystywności...
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublicationLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublicationThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Earth wires currents calculation by tableau analysis
PublicationThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublicationPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
The influence of the motor filtrers on harmonic current emmision in the pro-ective connection of drive systems.
PublicationThis paper contains detailed analysis of currents in protective wire in engine supplied from frequency converter without any external filters added. It was found that the peak value of current in protective conductor of engine was about 1500 mA at frequencies 5 Hz 50 Hz. In the continuation of research the dU/dt type motor filter and the sinusoidal filter were tested. It was found that the current in protective wire decreased...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublicationThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublicationCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublicationCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...