Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublicationThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Measurement of benzene concentration in urban air using passive sampling
PublicationAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
The influence of meteorological conditions and anthropogenic activities on the seasonal fluctuations of BTEX in the urban air of the Hanseatic city of Gdansk, Poland
PublicationThe results of studies conducted in Gdansk in the period from January to December 2013 and focused on the determination of BTEX in the atmospheric air are presented. At the stage of the isolation and/or enrichment of analytes from the gaseous medium, a passive sampling technique—Radiello® diffusive passive samplers, was applied. The time-weighted average annual concentration of benzene, toluene, ethylbenzene, and total xylenes...
-
Small-scale passive emission chamber for screening studies on monoterpene emission flux from the surface of wood-based indoor elements
PublicationAnalysis of literature data published in the last fewyears leads to the conclusion that in the process of assessment of emission flux of organic compounds emitted from different types of equipment and finishing materials, new types of devices, among which small-scale passive emission chambers for the performance of in-situ research are designed and applied on a larger scale. These devices can be successfully used for the assessment...
-
The Relationships Between BTEX, NOx, and O3 Concentrations in Urban Air in Gdansk and Gdynia, Poland
PublicationThis paper presents the results of atmospheric air quality research conducted in the areas of two shipyard cities: Gdansk and Gdynia (Poland), in the period between March and December 2011. The purpose of the research was focused on determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) compounds in atmospheric air. Passive sampling technique, with Radiello® diffusive passive samplers, was used for BTEX sample collection...
-
BTEX concentration levels in urban air in the area of the Tri-City agglomeration (Gdansk, Gdynia, Sopot), Poland
PublicationThe paper presents and discusses the results of atmospheric air quality research conducted in 2012 with reference to the level of BTEX compounds in the Tri-City agglomeration—Gdansk, Gdynia, and Sopot (northern Poland). At the stage of BTEX sampling from the ambient air, Radiello® diffusive passive samplers were applied. The annual time-weighted average concentrations for benzene, toluene, ethylbenzene, and xylenes (BTEX) in the...
-
Concentrations of monoaromatic hydrocarbons in the air of the underground car park and individual garages attached to residential buildings
PublicationThe paper describes the characteristics of a two-level underground car park and three individual garages attached to residential buildings, differing by the resident utilization habits, located in North Poland (Tri-City agglomeration area). The strategy of collecting the analyte samples from air in mentioned enclosed areas, concerning the determination of benzene, toluene, ethylbenzene, o-xylene and p,m-xylenes (BTEX) concentrations...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
PublicationNa Univeristy of Portsmouth (UK) opracowano próbnik pasywny typu Chemcatcher, który może być stosowany do długotrwałego monitoringu organicznych zanieczyszczeń wody. Na działanie wszystkich próbników pasywnych wpływ mają warunki środowiskowe takie jak np. ruch wody czy temperatura. Przed użyciem próbnika Chemcatcher w badaniach polowych wymagana więc była wcześniejsza kalibracja w laboratorium. Przedstawiono wyniki serii doświadczeń...
-
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublicationThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water
PublicationZaprojektowano nową obudowę próbnika typu Chemcatcher, tzw. próbnik typu Chemcatcher drugiej generacji. Większość badań kalibracyjnych przeprowadzono stosując próbnik typu Chemcatcher pierwszej generacji. Dlatego zbadano wpływ obudowy próbnika typu Chemcatcher na jego działanie.
-
Spatial and seasonal patterns of benzene, toluene, ethylbenzene, and xylenes in the Gdańsk, Poland and surrounding areas determined using Radiello passive samplers
PublicationCelem badań było uzyskanie informacji o poziomie zanieczyszczeń powietrza atmosferycznego przez związki z grupy BTEX na terenie aglomeracji Trójmiejskiej z wykorzystaniem techniki dozymetrii pasywnej na etapie pobierania próbek analitów. Próbniki pasywne Radiello były poddawane ekspozycji na stacjach pomiarowych zarządzanych przez fundację ARMAAG, zlokalizowanych na terenie aglomeracji Trójmiejskiej.Otrzymane informacje analityczne...
-
Unconventional and user-friendly sampling techniques of semi-volatile organic compounds present in an indoor environment: An approach to human exposure assessment
PublicationThe commonly applied solutions used to assess the potential risk of human exposure to semi-volatile organic compounds (SVOCs) are based on the investigation of biological samples collected in an invasive or non-invasive manner. For SVOCs, which are typically introduced to humans through the respiratory system, dermal adsorption, or digestive system, sampling solutions generally used in the indoor environments are classified as...
-
Ionic Liquid Assisted Dissolution of Dissolved Organic Matter and PAHs from Soil Below the Critical Micelle Concentration
PublicationIncreased use and production of ionic liquids (ILs) may result in emissions into the environment. Particularly vulnerable are industrial areas and landfills where ILs are utilized and ultimately disposed of. This study investigates how IL contamination can affect soil properties and the sorption of pre-existing contaminants. The commonly used IL 1-methyl-3-octyl imidazolium chloride ([OMIM][Cl]) was added at various quantities...