Abstrakt
OBJECTIVE. The purpose of this article is to evaluate the utility of ultrasound in identifying carotid bodies (CBs) in patients with drug-resistant arterial hypertension. SUBJECTS AND METHODS. We enrolled 13 patients with drug-resistant hypertension into a trial for surgical CB excision. CT angiography (CTA) and Doppler ultrasound (DUS) of the cervical arteries were performed before surgery. CBs were identified in a blind manner at both CTA and DUS. CBs were defined at CTA as ovoid avidly enhancing structures at the inferomedial aspect of the carotid bifurcation. At DUS, CBs were defined as ovoid solid structures in the inferomedial aspect of the bifurcation. RESULTS. CBs were identified in 12 of 13 patients (23/26 sides) using CTA and in 11 of 13 patients (18/26 sides) using DUS. Identification of CB with DUS and CTA correlated in 17 of 18 cases; in one instance, CB was identified with DUS but not CTA. There was no statistically significant difference in size and volume of CB measured by both methods. CONCLUSION. Noncarcinogenic CBs can be visualized using DUS, with good correlation of size and location compared with CTA. The findings show that DUS can be reliably used to further examine the role of CBs in cardiovascular disorders and can be used in conjunction with therapies that target CBs.
Cytowania
-
5
CrossRef
-
0
Web of Science
-
5
Scopus
Autorzy (9)
Cytuj jako
Pełna treść
pełna treść publikacji nie jest dostępna w portalu
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuł w czasopiśmie wyróżnionym w JCR
- Opublikowano w:
-
AMERICAN JOURNAL OF ROENTGENOLOGY
nr 209,
wydanie 6,
strony 1348 - 1352,
ISSN: 0361-803X - Język:
- angielski
- Rok wydania:
- 2017
- Opis bibliograficzny:
- Swieton D., Kaszubowski M. F., Szyndler A., Chrostowska M., Narkiewicz K., Szurowska E., Engelman Z., Piskunowicz M.: Visualizing Carotid Bodies With Doppler Ultrasound Versus CT Angiography: Preliminary Study// AMERICAN JOURNAL OF ROENTGENOLOGY. -Vol. 209, iss. 6 (2017), s.1348-1352
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.2214/ajr.17.18079
- Weryfikacja:
- Politechnika Gdańska
wyświetlono 116 razy
Publikacje, które mogą cię zainteresować
A Comparability of Renal Length and Volume Measurements in MRI and Ultrasound in Children
- D. Świętoń,
- W. Bernard,
- M. Grzywińska
- + 5 autorów
Monitoring of crosslinking of a DGEBA-PAMAM adhesive in composite/aluminium bonded joint using mechanical and ultra-sound techniques
- M. Budzik,
- B. Mascaro,
- J. Jumel
- + 2 autorów
Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients
- P. J. Winklewski,
- M. Kaszubowski,
- G. Halena
- + 7 autorów
US not bright but right method of thyroid volume estimation even in large and substernal extended goitres. Comparison of US and three methods of CT thyroid evaluation - prospective study.ON LINE
- S. Kaniuka-Jakubowska,
- M. Piskunowicz,
- A. Zapaśnik
- + 6 autorów