Filtry
wszystkich: 11322
wybranych: 2967
-
Katalog
- Publikacje 7575 wyników po odfiltrowaniu
- Czasopisma 206 wyników po odfiltrowaniu
- Konferencje 133 wyników po odfiltrowaniu
- Osoby 172 wyników po odfiltrowaniu
- Wynalazki 2 wyników po odfiltrowaniu
- Projekty 6 wyników po odfiltrowaniu
- Laboratoria 1 wyników po odfiltrowaniu
- Kursy Online 205 wyników po odfiltrowaniu
- Wydarzenia 22 wyników po odfiltrowaniu
- Dane Badawcze 3000 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: TRACK GEOMETRIC LAYOUT, GNSS/INS/MLS MEASUREMENTS, RTK MEASUREMENTS, DATA PROCESSING
-
Isothermal calorimetry data for cement pastes containing pristine and silica-coated bismuth oxide (Bi2O3) and gadolinium oxide (Gd2O3) structures
Dane BadawczeExcel file containing raw calorimetric data determined up to 168 h (Tam Air 3 8-channel isothermal calorimeter) of cement pastes containing variable amount of Bi2O3, Gd2O3, Bi2O3-SiO2 and Gd2O3-SiO2 structures. Sample designation in the Excel file is in line with sample designation in the manuscript associated with dataset.
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Białystok University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Opole University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Poznań University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Warsaw University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Silesian University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles.The most common definition of research productivity...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Technical University Radom 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Wrocław University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Cracow University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles.The most common definition of research productivity...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Łódź University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Lublin University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Gdańsk University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Kielce University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Technical University Częstochowa 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Koszalin University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
Bibliometric data for a research study on scientific productivity of Polish technical universities (Rzeszów University of Technology 2016-2020) retrieved by InCites benchmarking tool.
Dane BadawczeThis dataset was created for the purpose of research on scientific productivity at Polish technical universities.The raw data was retrieved in July 2021 by the InCites benchmarking tool in xlsx format and will be used to create the research profiles of the universities and underlying data of journals articles. The most common definition of research...
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using Al2O3/5%Cu catalyst
Dane BadawczeThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using AlOOH/1%Cu nanocatalyst. The specatra were collected every 1 minute from 800C to 500C. Reagent flow was set to 20ml/min.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using CeO2/5%Cu catalyst
Dane BadawczeThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using CeO2/5%Cu nanocatalyst. The specatra were collected every 1 minute from 800C to 500C. Reagent flow was set to 20ml/min.
-
Results of wettability evaluation of acrylic bone cements incorporating various components
Dane BadawczeThe database contains the images of the contact angle measurements of modified bone cements using the optical tensiometer. The following modifications were evaluated: the addition of biodegradable components (including chitosan, cellulose, tricalcium phosphate, polydioxanone or magnesium), the addition of bioactive components (bioglasses) or the addition...
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using Al2O3/5%Cu catalyst
Dane BadawczeThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using Al2O3 (TMDAR)/5%Cu nanocatalyst. The specatra were collected every 1 minute from 800C to 500C. Reagent flow was set to 20ml/min.
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...