Computer-aided analysis of thermal convection near electric devices
PublikacjaObciążalność długotrwała urządzeń elektrycznych zależy od intensywności oddawania ciepła przez te urządzenia do otoczenia. Dla zwiększenia obciążalności długotrwałej urządzeń stosuje się konwekcję wymuszoną np. z wykorzystaniem wentylatorów. Wszechstronne obserwacje i analiza procesów konwekcji naturalnej wskazują, że jej intensyfikację można uzyskać dzięki umieszczaniu w pobliżu urządzenia oddającego ciepło elementów tworzących...
-
Numerical and experimental investigation of thermal convection near electric devices with vertical channels
PublikacjaThis paper presents the results of numerical and experimental investigation of thermal convection near heat emitting surfaces of an electric device. For the intensification of thermal convection, special vertical channels were formed near the heat emitting surfaces of the device. An experimental test has proved that there is an optimal length of the channels – thermal convection is the most intensive then. Air velocity vectors...
-
Intensification of thermal convection near electric devices using flat screens – computer modelling
PublikacjaIntensification of natural thermal convection near electric devices is possible by application of additional elements as screens creating convection canals close to the device. In the earlier authors paper the results of the analysis of thermal convection with the use of only one additional screen close to the electric device were presented. This paper presents computer modelling of thermal convection when two screens near the...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublikacjaThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublikacjaA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
Protection Against Electric Shock Using Residual Current Devices in Circuits with Electronic Equipment
PublikacjaW artykule przedstawiono problematykę stosowania wyłączników różnicowoprądowych w obwodach z urządzeniami elektronicznymi, które powodują, że prąd różnicowy ma zmienną częstotliwość lub jest odkształcony. Wyniki badań wskazują, że częstotliwość obiegająca od znamionowej oraz zawartość wyższych harmonicznych w prądzie różnicowym niekorzystnie wpływa na skuteczność ochrony przeciwporażeniowej przy zastosowaniu wyłączników różnicowoprądowych....
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublikacjaW artykule przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oceniono skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania proponowanego wyłącznika różnicowoprądowego.
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublikacjaW referacie przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oszacowano wpływ tego odkształcenia na próg fibrylacji serca. Analizowano skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania zaproponowanego...
-
Exciton quenching in emitter blends for organic light emitting devices probed by electric field-dependent time-resolved luminescence
PublikacjaW pracy badano mechanizm wygaszania ekscytonów w układzie dwuamina TPD:organiczny kompleks Eu:matryca TPD przez pomiar zaniku fotoluminescencji w zewnętrznym polu elektrycznym.
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublikacjaThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Comparison of EHD devices with parallel and in series spiked electrodes
PublikacjaIn this paper two electrohydrodynamic (EHD) devices for gas pumping and cleaning are presented. In both cases to induce an airflow in these EHD devices corona discharge was used. The discharge was generated between the spiked electrodes set parallel (the first case) or in series (the second case) and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Interactive Application for Visualization of the Basic Phenomena in RF and Microwave Devices
PublikacjaAn interactive computer application visualizing the basic phenomena in RF and microwave devices is presented. Such kind of educational package can be a very helpful tool for the students as well as for the teachers (of electronics and related fields). This paper is focused on three exemplary problems only and involves: movement of electric charge, filtering of electromagnetic waves and interference phenomena in antenna arrays. The...
-
MEASUREMENT AND ANALYSIS OF ELECTRIC FIELD INTENSITY NEAR SELECTED TRANSMITTERS OF MOBILE TELEPHONY BASE STATIONS
PublikacjaWireless connectivity has become increasingly common in recent times. Day by day, there are more radiocommunication devices and new ideas for them. In the near future, when the fifth generation networks will be implemented, whose main feature will be continuous wireless communication, we must approach the issue of electric field measurements more and more carefully.