Application of the ‘CPT 2012’model of AFNOR standard for column design in Poland–Jazowa case study
Publikacjahis paper presents the ‘CPT 2012’ model incorporated into the AFNOR NF P94-262:2012-07, French standard for pile design fully compatible with Eurocode 7, to the wider Polish audience. The bearing capacity of three reference columns for Vistula Marshlands have been calculated according to ‘CPT 2012’ model and AFNOR recommendations. Then, the design resistances have been compared with ultimate column bearing capacity measured during...
-
Prediction of Pile Shaft Capacity in Tension Based on Some Direct CPT Methods—Vistula Marshland Test Site
PublikacjaThis paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with diameter 0.4 m and the length varied from 8 m to 14.6 m were subjected to static load tests in tension. Their...
-
Prediction of pile shaft capacity in tension based on some direct CPT methods – Vistula Marshland test site
PublikacjaThis paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with a diameter of 0.4 m and the length...