Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5
PublikacjaThe paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length‑to‑diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging between Re = 100 to 950. Based on the experimental tests, standard...
-
Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)
Dane BadawczeThe data was obtained as part of the project "Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)", in which flow tests of hydraulic oil through a cylindrical orifice with a thickness of l = 25 mm and a throat b = 0.5 (diameter pipes D = 50 mm, orifice diameter d = 25 mm) on the test stand at the Department...