Filtry
wszystkich: 5357
wybranych: 988
-
Katalog
- Publikacje 1797 wyników po odfiltrowaniu
- Czasopisma 93 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Wydawnictwa 4 wyników po odfiltrowaniu
- Osoby 196 wyników po odfiltrowaniu
- Projekty 34 wyników po odfiltrowaniu
- Kursy Online 121 wyników po odfiltrowaniu
- Wydarzenia 25 wyników po odfiltrowaniu
- Dane Badawcze 3086 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: render
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #3. This experiment was preceded by experiment 10.34808/m9mn-yy02. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #3. This experiment was preceded by experiment 10.34808/jf84-x137. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #2. This experiment was preceded by experiment 10.34808/v2hs-b595. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #4.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #4. This experiment was preceded by experiment 10.34808/jf84-x137. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 189 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 189 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #2. This experiment was preceded by experiment 10.34808/av2f-rb57The images were taken with thermographic camera VigoCAM V50....
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.30, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.20, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #2. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #5.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #5. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #5.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #5. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #10.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #10. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 420 mA. Sample 103, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J52.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J52. The period of images is 30 minutes in order to observe slow temperature fluctuations. The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #9.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #9. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,3 V at 420 mA. Sample 103, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,3 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #2. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #6.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #6. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #12.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #12. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #4.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #4. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #11.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #11. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #1. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #8.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #8. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #3. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #7.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #7. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 420 mA. Sample 103, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #1. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 420 mA. Sample 103, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 420 mA. Sample 103, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #1. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #3. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #1. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #7.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #7. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 420 mA. Sample 103, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #3. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #6.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #6. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #3. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #1. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...