Nie znaleźliśmy wyników w zadanych kryteriach!
Ale mamy wyniki w innych katalogach.Wyniki wyszukiwania dla: TRABECULAR
-
FEM approach to modeling of an irregular trabecular structure
PublikacjaThe aim of the study is elaboration of a method for creating irregular scaffolds that can be used to model the behaviour of trabecular bone placed in the proximal epiphysis of the femur. The scope of the study encompasses creating six numerical models of irregular scaffolds (two solid irregular scaffolds, two shell irregular scaffolds and two shell irregular scaffolds with fortification) and performing numerical analysis of the...
-
The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements.
PublikacjaBoundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58...
-
Chosen aspects of skeletal system modeling: Numerical solid and shell models of femur part
PublikacjaThe purpose of this paper is to present a new method of femur part modeling by using the finite element method. This method treats a femur part as a system composed of cortical and trabecular bone. For the purpose of determining a proper shape of femur part model there were created three models: a) the first one describes a femur part as a solid structure; b) the second one describes a femur part as a connection of cortical bone...
-
Hyalinizing trabecular tumor - Female, 47 - Tissue image [7100730013387901]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hyalinizing trabecular tumor - Female, 46 - Tissue image [11010630088573011]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hyalinizing trabecular tumor - Female, 46 - Tissue image [11010630088575051]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hyalinizing trabecular tumor - Female, 50 - Tissue image [11010630088574961]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hyalinizing trabecular tumor - Female, 46 - Tissue image [11010630088574301]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hyalinizing trabecular tumor - Female, 46 - Tissue image [11010630088574271]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hyalinizing trabecular tumor - Female, 46 - Tissue image [11010630088573441]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.