Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 3886
-
Catalog
- Publications 2535 available results
- Journals 5 available results
- Conferences 4 available results
- People 32 available results
- Inventions 1 available results
- Projects 2 available results
- Laboratories 1 available results
- Research Equipment 4 available results
- e-Learning Courses 127 available results
- Events 9 available results
- Offers 1 available results
- Open Research Data 1165 available results
displaying 1000 best results Help
Search results for: emission test chambers
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
NOx emission from a two-stroke ship engine: Part 2 – Laboratory test
Publication -
INTERLABORATORY COMPARISON OF THE ELECTROMAGNETIC EMISSION MEASUREMENTS USING FAR AND GTEM TEST SITES UP TO 1 GHz
PublicationElectromagnetic emission limiting is one of the basic requirements in the European Directive 2014/30/EU (EMC Directive). Manufacturers often use alternative methods of measurements to make preliminary verification of emission. This paper presents and analyzes problem with comparison between measurements in different test sites: FAR (Fully Anechoic Room) and GTEM (Gigahertz Transverse Electromagnetic cell). FAR is assumed as the...
-
Trends in Automotive Emission Legislation: Impact on LD Engine Development, Fuels, Lubricants and Test Methods: a Global View, with a Focus on WLTP and RDE Regulations
Publication -
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublicationThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air
PublicationAdults spend most of their time in enclosed spaces (e.g., apartment, office and public buildings). According to research conducted by scientists, air quality indoors is much worse than the ambient air quality outdoors. Hazardous chemicals found in air indoors can adversely affect the functioning of the human body and cause many respiratory and circulatory diseases. Harmful chemical compounds (mainly volatile organic compounds and...
-
Small-scale passive emission chamber for screening studies on monoterpene emission flux from the surface of wood-based indoor elements
PublicationAnalysis of literature data published in the last fewyears leads to the conclusion that in the process of assessment of emission flux of organic compounds emitted from different types of equipment and finishing materials, new types of devices, among which small-scale passive emission chambers for the performance of in-situ research are designed and applied on a larger scale. These devices can be successfully used for the assessment...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Investigations of the Working Process in a Dual-Fuel Low-Emission Combustion Chamber for an FPSO Gas Turbine Engine
PublicationThis investigation is devoted to an analysis of the working process in a dual-fuel low-emission combustion chamber for a floating vessel’s gas turbine. The low-emission gas turbine combustion chamber with partial pre-mixing of fuel and air inside the outer and inner radial-axial swirlers was chosen as the object of research. When modelling processes in a dual-flow low-emission gas turbine combustion chamber, a generalized method...