Filters
total: 3406
filtered: 1003
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: MEASUREMENT
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)
Open Research DataThe data was obtained as part of the project "Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)", in which flow tests of hydraulic oil through a cylindrical orifice with a thickness of l = 25 mm and a throat b = 0.5 (diameter pipes D = 50 mm, orifice diameter d = 25 mm) on the test stand at the Department...
-
Electrical performance measurement of reference and SOFC with LSCNT layer fueled by H2 and 20ppm H2S/biogas mixture at 750 C - cyclic measurements (12h per cycle)
Open Research DataThe dataset contains the electrical IV measurements collected during the cyclic measurements of H2S poisoning in DIR-SOFC with/-out LSCNT layer. The H2S poisoning and H2 regenrating cycles were 12 h each. The spectra were collected every 10 min.
-
Measurement file of stainless stell shaft LSS1 and LSS2 with diameter 95,995 with 3d measurment device
Open Research Data3d point cloud consist of measured points on new stainless steel shaft used during testing hydrodynamic journal PEEK bearing.
-
Experimental Study of the Influence of Noise Level on the Uncertainty Value in a Measurement System Containing an Analog-to-Digital Converter
Open Research DataFor newly developed measuring systems it is easy to estimate type B uncertainties based on the technical data of the measuring modules applied. However, it is difficult to estimate A type un-certainties due to the unknown type and level of interferences infiltrating into the measuring sys-tem. This is a particularly important problem for measurements...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
LIDAR data from a cliff measurement conducted in the vicinity of the town of Jastrzębia Góra on the Baltic Sea coast
Open Research DataMeasurement data were obtained during research related to the use of LiDAR observations to assess the stability of a coastal cliff. The collected information comes from measurements conducted in the vicinity of the town of Jastrzębia Góra on the Baltic Sea coast. The acquired point cloud constitutes a comprehensive set of data regarding the geometry...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – plug flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: plug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – slug flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: slug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique –bubble flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...