displaying 1000 best results Help
Search results for: PASSIVE SAMPLING TECHNIQUE
-
Increasing the Utilization of dc-link Voltage of a Five-Leg VSI Based on Rotor Angle Control of Dual Induction Motors
PublicationThis paper introduces an increased utilization of the dc-link voltage of a five-leg voltage source inverter (VSI) based on the rotor flux angle control technique for dual induction motors, IM. The main purpose is to utilize additional abilities provided by a multi-motor drive system in limited operating conditions. Generally, a multi-motor drive system is widely used in electric vehicles (EVs), traction systems and in several industrial...
-
A Broadband Circularly Polarized Wide-Slot Antenna with a Miniaturized Footprint
PublicationThis letter presents a novel and simple feeding technique for exciting orthogonal components in a wide-slot antenna. In this technique, a rectangular bracket-shape parasitic strip is placed at the open end of the straight microstrip line to excite the fundamental horizontal and vertical components of the circular polarization (CP). The proposed technique—when employed in conjunction with the asymmetrical geometry of coplanar waveguide...
-
Multi-fidelity EM simulations and constrained surrogate modelling for low-cost multi-objective design optimisation of antennas
PublicationIn this study, a technique for low-cost multi-objective design optimisation of antenna structures has been proposed. The proposed approach is an enhancement of a recently reported surrogate-assisted technique exploiting variable-fidelity electromagnetic (EM) simulations and auxiliary kriging interpolation surrogate, the latter utilised to produce the initial approximation of the Pareto set. A bottleneck of the procedure for higher-dimensional...
-
Fetal death of unspecified cause - Male, 0 - Tissue image [3140630024315261]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fetal death of unspecified cause - Male, 0 - Tissue image [314063002431991]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010642911]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Edwards' syndrome, unspecified - Male, 1 - Tissue image [3070630010187151]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Renal tubulo-interstitial disorders in other diseases classified elsewhere - Male, 67 - Tissue image [1206063001762681]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Disorders related to short gestation and low birth weight, not elsewhere classified - Male, 0 - Tissue image [6230730007859871]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of brain - Male, 56 - Tissue image [10060730015614911]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute renal failure, unspecified - Male, 50 - Tissue image [10110730048221551]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Renal tubulo-interstitial disorders in other diseases classified elsewhere - Male, 67 - Tissue image [12060630017628641]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010647891]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017626641]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010649371]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017623471]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Edwards' syndrome, unspecified - Male, 1 - Tissue image [3070630010183471]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017627681]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010647461]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 0 - Tissue image [3140630024328351]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Disorders related to short gestation and low birth weight, not elsewhere classified - Male, 0 - Tissue image [6230730007854321]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Disorders related to short gestation and low birth weight, not elsewhere classified - Male, 0 - Tissue image [6230730007856961]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Acute renal failure, unspecified - Male, 50 - Tissue image [10110730048223451]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Preterm labour with preterm delivery - Male, 0 - Tissue image [3280730025608321]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [1203063001762871]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenocarcinoma, NOS - Female, 76 - Tissue image [4080730010648641]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017621761]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fetal death of unspecified cause - Male, 0 - Tissue image [3140630024317491]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of brain - Male, 56 - Tissue image [10060730015618681]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010644421]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010646501]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017625991]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017622011]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Preterm labour with preterm delivery - Male, 0 - Tissue image [3280730025626861]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 76 - Tissue image [4080730010641261]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Preterm labour with preterm delivery - Male, 0 - Tissue image [3280730025608141]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017621051]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Preterm labour with preterm delivery - Male, 0 - Tissue image [3280730025625061]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of brain - Male, 56 - Tissue image [10060730015613391]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pneumonia, unspecified - Male, 65 - Tissue image [12030630017627091]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Female, 0 - Tissue image [3140630024321231]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of brain - Male, 56 - Tissue image [10060730015616241]
Open Research DataThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of spleen - Male, 65 - Tissue image [3300730069465691]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The influence of microstructure on the corrosion resistance for some titanium-based alloys
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs revealing the microstructure of some Ti-based alloys, namely: Ti-6Al-4V (file name: TiV), Ti-6Al-7Nb (file name: TiNb) and TC21 (file name: TiAlSnZrMoCrNbSi) alloys and their localized corrosion as a result of passive layer breakdown in a corrosive environment, ie. 0.9% NaCl solution...
-
Two tests for adhesive bonding long term characterization: principles and applications
PublicationThis article describes recent refinement of the traditional wedge test technique used to characterize durability of the adhesive joints. We propose two types of measuring protocols to monitor precisely and continuously the propagation of an "effective" crack during long term mode I fracture mechanic test. First method is directly derived from the traditional wedge test technique and consist in monitoring the surface strain of adherent...
-
Molecular dynamics and verisimilitude - to what extent can one trust a computational simulation?
PublicationFor the last several tens of years, computer simulations have become of undeniable importance. Molecular Dynamics (MD) simulation techniques are used to examine the phenomena which occur at the level that cannot be observed directly. Thus, they can be successfully exploited in many different scientific fields such as: materials science, applied mathematics and theoretical physics, biochemistry, biophysics or drug design. Despite...
-
Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
PublicationIn this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose...
-
New methodology for determination cationic surfactants in liquid environmental samples
PublicationBecause of their specific physical and chemical properties (e.g. amphiphilicity, solubility in polar and nonpolar liquids, ability to form micelles, adsorption at phase boundaries, low toxicity) surfactants (surface-active compounds) are widely applied in industry and in the household. As their applications are on a very large scale, it has become necessary to acquire a more detailed understanding of their environmental fate. Mainly,...
-
The morphology of lead-borate glasses and nanocomposites doped with iron oxide
Open Research DataThe topography of iron-doped borate glasses and glass-ceramics were studied. Samples of composition of xFe2O3–(100 − x)(B2O3–2PbO) (2.5 < x < 37 in mol%) were prepared by the conventional meltquenching technique. The melting was conducted in alumina crucibles at the temperature of 1523 K. The melts were poured on a preheated (573 K) brass plate...
-
The structure of lead-borate glasses containing nanocrystallites of iron oxides
Open Research DataThe structure of iron-doped glasses and glass-ceramics were studied. Glass samples of composition of xFe2O3–(100 − x)(B2O3–2PbO) (2.5 b x b 37, in mol%) were prepared by the conventional melt quenching technique. The melting was conducted in alumina crucibles at the temperature of 1523 K. The melts were poured on a preheated (573 K) brass plate and...