Search results for: fiber-optics%20sensors
-
Multicore fibers doped with neodymium for fiber laser application
Publication -
Yb3+/Ho3+-codoped antimony-silicate optical fiber
Publication -
Coherent beam combining of active multicore optical fiber
Publication -
Application of optical microsphere in fiber optic sensors for measurement of electrochemical processes
Open Research Datainvestigation of the electrochemical processes using micro-sphere fiber-optic sensor with a zinc oxide (ZnO) coating applied by Atomic Layer Deposition method (ALD). The measurements were performed in 1M KNO3 during a decomposition of Bisphenol-A
-
Korean Journal of Optics and Photonics
Journals -
Advanced Materials for Optics and Electronics
Journals -
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublicationAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Effect of Laminar Pulsatile Fluid Flow on Separation of Volatile Organic Compounds from Aqueous Solution by a Hollow Fiber Membrane-Based Process
PublicationIn this study, a laminar pulsatile fluid flow was used for the separation of benzene, toluene, ethylbenzene, and xylene isomers (BTEX) from aqueous solutions. Polyether sulfone hollow fiber membrane has been applied to this process. The effects of BTEX concentration, and feed and extraction flow rates were examined. It was found that the application of the pulsatile fluid flow with...
-
Screw displacement pile shaft deformations measured by vibrating wire and fiber optic systems during a static load test
PublicationThis paper describes a full scale static load test performed on a 400 mm diameter screw displacement pile equipped with four different strain measuring systems. Three types of vibrating wire strain gauges (VWSG) were used: global - retrievable, local attached to steel pipe and local concrete embedded. The fourth system was distributed fiber optic sensors based on Rayleigh back scattering (DFOS) - three in the pile cross section....
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublicationThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
<title>Fiber optic probe for monitoring of drinking water</title>
Publication -
Assessment of water quality based on multiparameter fiber optic probe
Publication -
Hybrid Integrated Components For Optical Fiber Communication And Instrumentation Systems
Publication -
<title>Technology of soft-glass optical fiber capillaries</title>
Publication -
Fiber-optic temperature sensor using low-coherence interferometry
Publication -
Modeling of active fiber Bragg grating underwater acoustic sensor.
PublicationW pracy przedstawiono wyniki modelowania nowego typu przetwornika hydroakustycznego wykorzystującego światłowodową siatkę Bragga. Siatka ta, domieszkowana jonami pierwiastków ziem rzadkich, pracuje jako laser z rozłożonym sprzężeniem zwrotnym, co pozwala na znaczne zwiększenie czułości tego prztwornika w porównaniu z rozwiązaniami wykorzystującymi siatki pasywne. W celu uzyskania równomiernego rozkładu naprężeń siatki zastosowano...
-
Time-of-flight fiber optic sensors for strain and temperature measurement
PublicationW pracy przedstawiono światłowodowy sensor czasu przelotu do pomiaru odkształceń i temperatury mogący pracować zarówno w modzie transmisyjnym, jak i odbiciowym. W pomiarach czasu przelotu wykorzystano krótkie impulsy światłowodowe wprowadzane do jednodomowego światłowodu. Pod wpływem czynników zewnętrznych (temperatura, odkształcenie, siła rozciągająca) zmieniała się droga optyczna w światłowodzie, co powodowało zmiany czasu przelotu...
-
Optical fiber head for monitoring of heart rate and blood oxygenation
Publication -
Properties of Eu3+ doped poly(methyl methacrylate) optical fiber
Publication -
Phase-locking of 7-core Yb3+-doped optical fiber
Publication -
Application of the Fractional Fourier Transform for dispersion compensation in signals from a fiber-based Fabry-Perot interferometer
PublicationOptical methods of measurement do not require contact of a probe and the object under study, and thus have found use in a broad range of applications such as nondestructive testing (NDT), where noninvasive measurement is crucial. Measuring the refractive index of a material can give a valuable insight into its composition. Low‑coherence radiation sources enable measurement of the sample’s properties across a wide spectrum, while...
-
Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing
PublicationSelected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water...
-
Combined Long-Period Fiber Grating and Microcavity In-Line Mach–Zehnder Interferometer for Refractive Index Measurements with Limited Cross-Sensitivity
PublicationThis work discusses sensing properties of a long-period grating (LPG) and microcavity in-line Mach–Zehnder interferometer (µIMZI) when both are induced in the same single-mode optical fiber. LPGs were either etched or nanocoated with aluminum oxide (Al2O3) to increase its refractive index (RI) sensitivity up to ≈2000 and 9000 nm/RIU, respectively. The µIMZI was machined using a femtosecond laser as a cylindrical cavity (d = 60...
-
FTIR Study and Mechanical Properties of Cellulose Fiber-Reinforced Thermoplastic Composites
Publication -
Optical fiber technology in Poland: four decades of development 1975-2015
Publication -
<title>Colorimetric sensor based on two optical fiber couplers</title>
Publication -
Directions Of Applications Of Optical Fiber Technology In Medicine And Health Protection Systems
Publication -
Recognition Of Colours And Collision Avoidance In Robotics Using Optical Fiber Sensors
Publication -
<title>Temperature sensor based on double-core optical fiber</title>
Publication -
<title>Optical fiber transmission with wavelength multiplexing: faster or denser?</title>
Publication -
<title>Atom guiding in single mode optical fiber capillary</title>
Publication -
Characterization of fatty acids composition in the European beaver (Castor fiber L.).
PublicationW pracy przedstawiono zawartość lipidów , klas lipidów i skład kwasów tłuszczowych lipidów ogólnych uzyskanych z różnych tkanek bobra europejskiego (tkanka okołojelitowa, tkanka okołonerkowa, miesień uda, mięsień kreskowy, podskórna tkanka tłuszczowa, ogon). Wykazano różnice w zawartości lipidów i składzie KT w tkankach samic (n=7) i samców (n=3). Wykazano wysokie zawartości nienasyconych KT w tkankach bobrów w porównaniu z tkankami...
-
Quasi-Static and Dynamic Testing of Carbon Fiber Reinforced Magnesium Composites
Publication -
PROPERTIES OF FIBER REINFORCED CEMENT COMPOSITES WITH CENOSPHERES FROM COAL ASH
Publication -
Side-Detecting Optical Fiber Doped with Tb3+ for Ultraviolet Sensor Application
Publication -
Optical properties of spirooxazine-doped PMMA fiber for new functional applications
Publication -
Phase-locking of optical fiber with hexagonal cores array doped with neodymium
Publication -
Upconversion luminescence in tellurite optical fiber codoped with Yb3+/Ho3+ions
Publication -
Instrumentation optical fibres for wave transformation, signal processing, sensors, and photonic functional components, manufactured at Białystok University of Technology in Dorosz Fibre Optics Laboratory
Publication -
APPLIED PHYSICS B-LASERS AND OPTICS
Journals -
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...