Filters
total: 2154
displaying 1000 best results Help
Search results for: BODY-TO- BODY NETWORKS
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023431121]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023438471]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023439081]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023438521]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023435111]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023438501]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CORPUS UTERI, Body of uterus - Female, 70 - Tissue image [6100730023433401]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Density functional approaches to the many-body problem
e-Learning Courses -
PULSE and ECG measurement from the hand with elbows to the body - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Foreign body granuloma of skin and subcutaneous tissue - Female, 59 - Tissue image [10040729541218751]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Foreign body granuloma of skin and subcutaneous tissue - Female, 59 - Tissue image [10040729541215261]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
PULSE and ECG measurement from the hand with elbows to the body - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Significant Decrease in Glycated Hemoglobin, 2h-Post-Load Glucose and High-Sensitivity C-Reactive Protein Levels in Patients with Abnormal Body Mass Index after Therapy with Manual Lymphatic Drainage
Publication -
Golden artefacts, resin figurines, body adhesives and tomb sediments from the pre-Columbian burial site El Caño (Gran Coclé, Panamá): tracing organic contents using molecular archaeometry
PublicationThis research aimed to determine the origin of organic residues from funerary contexts in the El Ca~no settlement (Gran Cocl�e area, Panam�a, Central America) by means of multiple molecular probing techniques (GC-MS of organic solvent extracts and pyrolysis-GC-MS, THM-GC-MS and FTIR of solid samples). The samples include particles of precious resin figurines, fillings of golden objects, tomb sediments, plant exudates from extant...
-
Foreign body granuloma of soft tissue, not elsewhere classified - Male, 55 - Tissue image [6130730026849561]
Open Research DataThis is the histopathological image of OTHER AND UNSPECIFIED PARTS OF MOUTH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Heart rate PPG signals with acceleration captured at wrist during small and moderate body movements
Open Research DataHeart rate PPG signals with acceleration captured at wrist during small and moderate body movements
-
Quantum Correlations of a Few Bosons within a Harmonic Trap
Publication -
Ground-State Entanglement Properties of Helium Atom in a Finite Spherical Cavity
Publication -
Note on the Harmonic Approximation in the Treatment of Entanglement: N Cold Trapped Ions
Publication -
Two-Boson Correlations in Various One-Dimensional Traps
Publication -
Test of an Optimised Exact-Diagonalization Approach for Trapped Fermionic Mixtures
Publication -
Correlation Effects in the Moshinsky Model
Publication -
Entanglement Entropies in the Ground States of Helium-Like Atoms
Publication -
Doubly Excited Resonance States of Helium Atom: Complex Entropies
Publication -
Correlation and Entanglement in Elliptically Deformed Two-Electron Quantum Dots
Publication -
Entanglement in Hooke’s Law Atoms: an Effect of the Dimensionality of the Space
Publication -
Entanglement of Two Charged Bosons in Strongly Anisotropic Traps
Publication -
Fermionized Dipolar Bosons Trapped in a Harmonic Trap
Publication -
Quantum Entanglement of Two Harmonically Trapped Dipolar Particles
Publication -
Sławomir Jerzy Ambroziak dr hab. inż.
PeopleSławomir J. Ambroziak was born in Poland, in 1982. He received the M.Sc., Ph.D. and D.Sc. degrees in radio communication from Gdańsk University of Technology (Gdańsk Tech), Poland, in 2008, 2013, and 2020 respectively. Since 2008 he is with the Department of Radiocommunication Systems and Networks of the Gdańsk Tech: 2008-2013 as Research Assistant, 2013-2020 as Assistant Professor, and since 2020 as Associate Professor. He is...
-
Deep neural networks for human pose estimation from a very low resolution depth image
PublicationThe work presented in the paper is dedicated to determining and evaluating the most efficient neural network architecture applied as a multiple regression network localizing human body joints in 3D space based on a single low resolution depth image. The main challenge was to deal with a noisy and coarse representation of the human body, as observed by a depth sensor from a large distance, and to achieve high localization precision....
-
Influence of User Mobility and Antenna Placement on System Loss in B2B Networks
PublicationIn this paper, the influence of user mobility and on-body antenna placement on system loss in body-to-body communications in indoor and outdoor environments and different mobility scenarios is studied, based on system loss measurements at 2.45 GHz. The novelty of this work lies on the proposal of a classification model to characterise the effect of user mobility and path visibility on system loss, allowing to identify the best...
-
Wojciech Siwicki dr inż.
People -
Krzysztof Cwalina dr inż.
PeopleKrzysztof Kamil Cwalina w 2013 r. uzyskał tytuł inżyniera na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej; w 2014 r. uzyskał tytuł magistra inżyniera, a w 2017 r. otrzymał stopień doktora nauk technicznych w dyscyplinie: telekomunikacja, także na WETI PG. Aktualnie pracuje na stanowisku adiunkta w Katedrze Systemów i Sieci Radiokomunikacyjnych Wydziału Elektroniki, Telekomunikacji i Informatyki Politechniki...
-
Robert Burczyk mgr inż.
PeopleRobert Burczyk received Eng. degree and M. SC. Eng. degree in electronics and telecommunictions engineering in 2017 and 2018 successively with specialization in radiocommunication systems and networks. The subject of the dissertations was focused on Wireless Body Area Network (WBAN). Currently, he is a PhD student and an employee at the Department of Radiocommunication Systems and Networks, Gdansk University of Technology. His...
-
Badanie i analiza efektywności alokacji strumieni danych w heterogenicznej sieci WBAN
PublicationW niniejszej dysertacji doktorskiej poddano dyskusji efektywność alokacji strumieni danych w heterogenicznej radiowej sieci WBAN (Wireless Body Area Networks). Biorąc pod uwagę dynamiczny rozwój nowoczesnych sieci radiokomunikacyjnych piątej generacji (5G), którego część stanowią radiowe sieci działające w obrębie ciała człowieka, bardzo ważnym aspektem są metody maksymalizujące wykorzystanie dostępnych zasobów czasowo –częstotliwościowych...
-
ANN for human pose estimation in low resolution depth images
PublicationThe paper presents an approach to localize human body joints in 3D coordinates based on a single low resolution depth image. First a framework to generate a database of 80k realistic depth images from a 3D body model is described. Then data preprocessing and normalization procedure, and DNN and MLP artificial neural networks architectures and training are presented. The robustness against camera distance and image noise is analysed....
-
Depolarisation Model for a BAN Indoor Scenario
PublicationIn this paper, an analysis of depolarisation in Body Area Networks for Body-to-Infrastructure communications based on a measurement campaign in the 5.8 GHz band in an indoor environment is performed. Measurements were made with an offbody antenna transmitting linearly polarised signals and dualpolarised receiving antennas carried by the user on the body. A Normal Distribution with a mean of 2.0 dB and a standard deviation of 4.3...
-
Knowledge representation of motor activity of patients with Parkinson’s disease
PublicationAn approach to the knowledge representation extraction from biomedical signals analysis concerning motor activity of Parkinson disease patients is proposed in this paper. This is done utilizing accelerometers attached to their body as well as exploiting video image of their hand movements. Experiments are carried out employing artificial neural networks and support vector machine to the recognition of characteristic motor activity...
-
Age Prediction from Low Resolution, Dual-Energy X-ray Images Using Convolutional Neural Networks
PublicationAge prediction from X-rays is an interesting research topic important for clinical applications such as biological maturity assessment. It is also useful in many other practical applications, including sports or forensic investigations for age verification purposes. Research on these issues is usually carried out using high-resolution X-ray scans of parts of the body, such as images of the hands or images of the chest. In this...
-
Novel Adaptive Method for Data Streams Allocation Based on the Estimate of Radio Channel Parameters in Heterogeneous WBAN Network
PublicationThe new adaptive method for data streams allocation in heterogeneous Wireless Body Area Networks and meas-urement equipment is presented. The results obtained using the developed method compared with the selected algorithms likely to be used in those networks. The pro-posed adaptive data streams allocation method based on radio channel parameters makes it even twice as efficient to use in terms of resources usage in a WBAN heterogeneous...
-
Joanna Rymaszewska prof. dr hab. n. med.
PeopleCV Joanna Rymaszewska Wroclaw University of Science and Technology, Wroclaw, Poland +48 601 98 26 24, joanna.rymaszewska@pwr.edu.pl orcid.org/0000-0001-8985-3592 2023 → Professor of Wroclaw University of Science and Technology (WUST), Poland 2011 → 2023 Professor of Wroclaw Medical University (WMU), PL 2016 → 2022 Head of the Department of Psychiatry, Wroclaw Medical University 2016 → 2022 Head of the Clinic of Psychiatry,...
-
IoT for healthcare applications
PublicationThis chapter summarizes IRACON contributions related to the application of IoT in healthcare. It consists of the following three sections. Section 8.1 presents the measurement campaigns and the related statistical analysis to obtain various channel models for wearable and implantable devices. In addition, the importance of physical human-body phantoms used for channel, Specific Absorption Rate (SAR), and Electromagnetic (EM) exposure...
-
Improving Accuracy of Contactless Respiratory Rate Estimation by Enhancing Thermal Sequences with Deep Neural Networks
PublicationEstimation of vital signs using image processing techniques have already been proved to have a potential for supporting remote medical diagnostics and replacing traditional measurements that usually require special hardware and electrodes placed on a body. In this paper, we further extend studies on contactless Respiratory Rate (RR) estimation from extremely low resolution thermal imagery by enhancing acquired sequences using Deep...