Filters
total: 4397
-
Catalog
displaying 1000 best results Help
Search results for: active power filter
-
A filter bank solution for active power filter control algorithms
PublicationThb paper describes the proposed active power fiIter (APF) with a new control circuit based on an algorithm using ufilter bank and a harmonic predictor. The conirol circuit was realized using the digiiaI signor processor ADSP-21065L and FPGA circuiL In the proposed circuit transient performunee of APF is improved The active power fdter circuil has been built and teste6 and some illustrative, experimental results are uIso presented...
-
Predictive control system of the shunt active power filter
Publication -
New control system of the shunt active power filter
Publication -
A Special Multi-Pulse Converter with Small Active Power Filter
Publication -
Experimental tests results of the diode rectifier with series active power filter
Publication -
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publication -
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublicationThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
A diode rectifier with a Special Coupled Reactor and additional Active Power Filter in the Marine Local Power Network Supply Conditions
Publication -
High power, medium voltage, modular active power filtering system
Publication -
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublicationThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
Supply system based on the 18-pulse diode rectifier with coupled reactors and integrated with the series active power filter
Publication -
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Sensorless predictive control of three-phase parallel active filter
PublicationThe paper presents the control system of parallel active power filter (APF) with predictive reference current calculation and model based predictive current control. The novel estimator and predictor of grid emf is proposed for AC voltage sensorless operation of APF, regardless of distortion of this voltage. Proposed control system provides control of APF current with high precision and dynamics limited only by filter circuit parameters....
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
General Active-RC filter model for computer-aided design
PublicationW pracy przedstawiono ogólną topologię filtru aktywnego RC czasu ciągłego. Proponowany model umożliwia zunifikowaną analizę wszystkich możliwych realizacji układowych filtrów aktywnych RC jako szczególnych przypadków danej struktury ogólnej. Poprawność modelu teoretycznego została zweryfikowana poprzez symulacje w programie SPICE.
-
Predictive control of active filter system with LCL coupling circuit
Publication -
Sensorless predictive control of three-phase parallel active filter
Publication -
A simple modular active power electronic transformer
Publication -
A boost topology active power factor corrector.
PublicationPrzedstawiono układ analogowego aktywnego korektora zbudowanego na układzie scalonym kontrolera PWM oraz tranzystorem MOS jako okresowo przełączonym kluczem. Układ korektora zapewnia pobór prądu z sieci energetycznej w postaci przebiegu prawie sinusoidalnego o małych zniekształceniach i w fazie z sinusoidalnym napięciem sieci.
-
Continuous-Time Active-RC Filter Model for Computer-Aided Design and Optimization
PublicationW pracy przedstawiono ogólny model filtru aktywnego RC opartego na wzmacniaczach odwracajacych faze. Model analizowany jest przy użyciu równań macierzowych. Podano jawną formułę określającą funkcję przenoszenia filtru w ogólnym przypadku. Przedstawiono rozszerzenia modelu pozwalające uwzgledniać nieidealność wzmacniaczy operacyjnych, w tym skończone wzmocnienie i pasmo przenoszenia oraz niezerową rezystancję wyjściową. Wyprowadzono...
-
Design of a simple modular active power electronic transformer
Publication -
High power, zero ripples active filtering system with power modules operating in parallel
Publication -
A novel approach to energy safety improvement in the marine power plants with active power surge compensator
PublicationPaper raises a point of power surges and theirs adverse effects in the marine power plants. The article explains a source of surges appearance, and presents measurements carried out on a modern ship. It discusses effects of dynamic power transients on the ship’s energy safety. Finally it proposes, a novel approach for power surge elimination, based on medium voltage active conditioner. As well as it propose the topology and control...
-
Design and evaluation of a base module of active power electronic transformer
PublicationThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
Design and evaluation of a base module of active power electronic transformer
Publication -
Measurements of active power coefficients in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing active...
-
Measurements of active power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data expressing an active...
-
Single-phase power electronics transformer with active functions for smart grid
PublicationThis paper presents the control of one cell of a modular single-phase power electronics transformer with active functions for meeting the smart grid concept. In this way, the converter could be used not only as a conventional transformer but also for grid such as reactive power, harmonic elimination and energy storage. The topology of the cell is composed by a bidirectional converter with three stages: a half bridge in the input...
-
Single-phase power electronics transformer with active functions for smart grid
Publication -
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublicationPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...
-
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublicationA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
Fully Tunable Analog Biquadratic Filter for Low-Power Auditory Signal Processing in CMOS Technologies
PublicationA novel Gm-C structure of a second-order continuous-time filter is proposed that allows for the independent control of the filter’s natural frequency (ω0) and quality factor (Q). The structure consists of two capacitors and four transconductors. Two transconductors together with the capacitors form a lossless second-order circuit with tunable ω0. The other two transconductors form a variable gain amplifier (VGA) which realizes...
-
Measurements of the coefficients of active power distribution between two generators operating in parallel in a ship power station
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing coefficients...
-
A new method of wind farm active power curve estimation based on statistical approach
PublicationThe purpose of this paper is to solve the wind farm active power estimation problem, introducing the method which is based on a statistical approach and robust fitting. The proposed algorithm uses a statistical approach and compared to existing ones- includes a wind direction as well as the influence of turbine start-up procedure on the estimation. The results show that additional estimation inputs i.e. the wind direction and the...
-
The use of a static electrical energy meter as a transducer of active power to a pulse frequency signal
Publication -
Will Music Give Me Power? Effects of Listening to Music during Active and Passive Rest Intervals on Power Output during Resistance Exercise
Publication -
The impact of the distribution network reconfiguration on active power losses: Selected issues of UPGRID project realization
PublicationThe dynamic development of smart grids allows the use of remote controllable switches to change the configuration of the distribution network. The paper discusses the impact of the distribution system reconfiguration on active power losses, taking into account the typical daily load profiles. Based on modified IEEE 33-bus test distribution system the article presents the method of selection the appropriate sensitivity factor and...
-
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublicationПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
Analytical Estimation of Power Losses in a Dual Active Bridge Converter Controlled with a Single-Phase Shift Switching Scheme
PublicationMicro-grid solutions around the world rely on the operation of DC/DC power conver- sion systems. The most commonly used solution for these topologies is the use of a dual active bridge (DAB) converter. Increasing the efficiency and reliability of this system contributes to the improvement in the stability of the entire microgrid. This paper discussed an analytical method of energy efficiency and power loss estimation in a single...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Interconnection of the Customer-Side Resources Using Single Phase VAPF
PublicationThe paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.
-
Highly linear CMOS triode transconductor for VHF applications
PublicationA high-speed, fully balanced complementary-symmetry metal-oxide-semiconductor (CMOS) triode transconductor is presented. The proposed approach exploits a pseudo-differential-pair triode configuration with a simple adaptive circuit stabilising the drain-to-source voltages of metal-oxide-semiconductor (MOS) transistors. Since no additional active circuits (apart from the resistors made of the cut-off MOS devices) and no feedback...
-
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublicationW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: otwartego, zamkniętego...