Search results for: emc
-
Kompatybilność Elektromagnetyczna Aparatury Medycznej
e-Learning CoursesOmówienie podstaw EMC - odporności i emisyjności urządzeń z naciskiem na specyfikę urządzeń medycznych
-
Ryszard Katulski prof. dr hab. inż.
People -
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Zmiany w instalacjach stacjonarnych a spełnienie wymagań emisji przewodowej
PublicationW pracy przedstawiono wyniki pomiarów emisji przewodowej przeprowadzonych w zakładowym laboratorium EMC obwodów zasilania instalacji alarmowych na zgodność z wymaganiami normy EN 55022 (dla urządzeń klasy B) w których nastąpiła zmiana zasilacza AC/AC względem zalecanej przez producenta konfiguracji. Uzyskane wyniki wskazują, że stosunkowo niewielkie odstępstwo od zalecanej konfiguracji instalacji skutkują przekroczeniem poziomów...
-
Kompatybilność elektromagnetyczna urządzeń i systemów przeznaczonych na jednostki pływające - Wymagania i metody badań
PublicationScharakteryzowano zagadnienia wpływu uwarunkowań kompatybilności elektromagnetycznej (EMC) na pracę okrętowych systemów teleinformatycznych. Opisano wymagania stawiane urządzeniom i systemom pracującym w takim środowisku.
-
Conducted emi propagation modelling in the wound components.
PublicationThe modelling of EMC behaviour of power electronics converters require specific models of devices which are adequate in a wide frequency range. A novel equivalent-circuit model of the inductor, suitable for EMC applications, has been developed and validated. The model can be used for the analyses of wounded components' behaviour in the conducted-EMI frequency range. The parameters of the proposed model can be evaluated based on...
-
FPGA-Based System for Electromagnetic Interference Evaluation in Random Modulated DC/DC Converters
PublicationField-Programmable Gate Array (FPGA) provides the possibility to design new “electromagnetic compatibility (EMC) friendly” control techniques for power electronic converters. Such control techniques use pseudo-random modulators (RanM) to control the converter switches. However, some issues connected with the FPGA-based design of RanM, such as matching the range of fixed-point numbers, might be challenging. The modern programming...
-
CM Voltage Compensators for Power Electronic Interfaces
PublicationThe experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Enhanced Toxicity of Bisphenols Together with UV Filters in Water: Identification of Synergy and Antagonism in Three-Component Mixtures
PublicationContaminants of emerging concern (CEC) localize in the biome in variable combinations of complex mixtures that are often environmentally persistent, bioaccumulate and biomagnify, prompting a need for extensive monitoring. Many cosmetics include UV filters that are listed as CECs, such as benzophenone derivatives (oxybenzone, OXYB), cinnamates (2-ethylhexyl 4-methoxycinnamate, EMC) and camphor derivatives (4-methylbenzylidene-camphor,...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
High Frequency Conducted Emission in AC Motor Drives Fed By Frequency Converters: Sources and Propagation Paths
PublicationProvides a concise and thorough reference for designing electrical and electronic systems that employ adjustable speed drives Electrical and electronic systems that employ adjustable speed drives are being increasingly used in present-day automation applications. They are considered by many application engineers as one of the most interfering components, especially in a contemporarily faced industrial environment. This book fills...
-
Naval electromagnetic compatibility investigations by use of topological model
PublicationPublikacja przedstawia zagadnienie uwarunkowań kompatybilnościowych na statkach. Ze względu na trudności jakie stwarza analiza EMC dużych obiektów, środowisko elektromagnetyczne okrętów jest zwykle dzielone na fragmenty analizowane oddzielnie. Referat przedstawia topologiczny model środowiska elektromagnetycznego w formie macierzowej, który pozwala na kompleksową analizę zagadnień kompatybilnościowych wielu systemów pracujących...
-
INTERLABORATORY COMPARISON OF THE ELECTROMAGNETIC EMISSION MEASUREMENTS USING FAR AND GTEM TEST SITES UP TO 1 GHz
PublicationElectromagnetic emission limiting is one of the basic requirements in the European Directive 2014/30/EU (EMC Directive). Manufacturers often use alternative methods of measurements to make preliminary verification of emission. This paper presents and analyzes problem with comparison between measurements in different test sites: FAR (Fully Anechoic Room) and GTEM (Gigahertz Transverse Electromagnetic cell). FAR is assumed as the...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Komputerowe szacowanie zaburzeń elektromagnetycznych
PublicationPrzedstawiono symulacyjne badania porównawcze w zakresie kompatybilności elektromagnetycznej EMC modelu obwodowego przetwornicy DC-DC podwyższającej napięcie. Zbadano wrażliwość uzyskanego modelu na kolejne uproszczenia jego postaci, w ten sposób otrzymując zredukowany, równoważny model do oszacowania charakterystyki widma zaburzeń EMI na sieci sztucznej. Taki model zrealizowano w symulatorze TCad i porównano zgodność wyników symulacji...
-
Wykorzystanie procedur oceny zgodności do optymalizacji konstrukcji urządzeń w inteligentnych instalacjach elektrycznych
PublicationW referacie przedstawiono wybrane zalecenia normalizacyjne związane z wymaganiami dyrektywy kompatybilności elektromagnetycznej (EMC) dla urządzeń automatyki zawierających wyposażenie elektroniczne. Wprowadzanie powyższych wyrobów do obrotu na rynku europejskim wymaga przeprowadzenia oceny zgodności produktu z wymaganiami odpowiednich dyrektyw: niskonapięciowej, kompatybilności elektromagnetycznej, a w przypadku sterowania bezprzewodowego...