Filters
total: 2442
-
Catalog
- Publications 2192 available results
- Journals 12 available results
- Conferences 6 available results
- People 32 available results
- Inventions 4 available results
- Projects 5 available results
- Research Equipment 11 available results
- e-Learning Courses 26 available results
- Events 8 available results
- Open Research Data 146 available results
displaying 1000 best results Help
Search results for: turbo generator
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
The distributed model predictive controller for the nuclear power plant turbo-generator set
PublicationTypically there are two main control loops with PI controllers operating at each turbo-generator set. In this paper a distributed model predictive controller DMPC, with local QDMC controllers for the turbine generator, is proposed instead of a typical PI controllers. The local QDMC controllers utilize step-response models for the controlled system components. These models parameters are determined based on the proposed black-box...
-
Robustness Analysis of a Distributed MPC Control System of a Turbo-Generator Set of a Nuclear Plant – Disturbance Issues
PublicationTypically, there are two main control loops with PI controllers operating at each turbo-generator set. In this paper, a distributed model predictive controller with local quadratic model predictive controllers for the turbine generator is proposed instead of a set of classical PI controllers. The local quadratic predictive controllers utilize step-response models for the controlled system components. The parameters of these models...
-
Event-Triggered Communication in Cooperative, Adaptive Model Predictive Control of a Nuclear Power Plant’s Turbo–Generator Set
PublicationThis paper discusses the issue of optimizing the communication between the components of a cooperating control system formed by a pair of MPC controllers of a nuclear power plant turbine set using online recursive least squares identification. It is proposed to use event-triggered communication, i.e., sending information only at selected time instants, as opposed to the standard approach where communication is triggered by time...
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublicationAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
Security Assessment of a Turbo-Gas Power Plant
PublicationCritical infrastructures are exposed to new threats due to the large number of vulnerabilities and architectural weaknesses introduced by the extensive use of information and communication technologies. This paper presents the results of an exhaustive security assessment for a turbo-gas power plant.
-
Modelowanie niepewności pomiarowych obiegu turbo parowego.
PublicationArtykuł opisuje próbę stworzenia modelu neuronowego wymiennika regeneracyjnego siłowni kondensacyjnej pracującego w zmiennych warunkach ruchu. Wzorzec poprawnej pracy elementów siłowni turboparowej jest pożądany w dziedzinie diagnostyki, ponieważ poprawnie pracujący model neuronowy jest w stanie zastąpić czasochłonne obliczenia bilansowe.
-
Koncepcja i symulacja polowa generatora o zmiennej częstotliwości. Zastosowanie w autonomicznych systemach elektroenergetycznych = Conception and field simulations of a variable frequency generator. Application for autonomous power generation system
PublicationStreszczenie angielskie: This paper covers a conception and simulation results for a brushless synchronous generator working with variable speed in an autonomous energy generation system (e.g. airplane power grid, hybrid vehicle, micro-CHP). The papers has two parts: presentation of the generator conception used in modern autonomous energy generation systems, and simulation results using filed model elaborated in Flux2D software....
-
Transmission Quality in MC-CDMA Radio Interface with Turbo Codes
PublicationMulti-Carrier Code Division Multiple Access techiques is a combination of two radio access techniques: Code Division Multiple Access (CDMA) and Orthogonal Frequency-called Division Multiplexing (OFDM) and has the advantages of both techniques. The paper presents the design of transmitter and receiver for MC-CDMA radio interface and the simulation results of the transmission quality in AWGN channel.
-
Comparison of the Efficiency of Turbo Codes with Mechanisms of Reducing the Number of Iterations
PublicationThe paper presents the construction of encoders and decoders turbo codes with different number of states. Simulation results of the transmission quality of the turbo codes were presented. Decoders for turbo codes have worked with a fixed number of iterations and with the mechanisms reducing the number of iterations. Data were transmitted in Outdoor to Indoor & Pedestrian B environment for data rate 384 kbps. The SOVA algorithm...
-
Modelowanie neuronowe regeneracyjnego wymiennika ciepła siłowni turbo parowej
PublicationWystąpienie ma na celu pokazać możliwości wykorzystania sztucznych sieci neuronowych do odtworzenia pracy wymienników regeneracyjnych elektrowni kondensacyjnej. Model pracy wymienników w zmiennych warunkach ruchu siłowi turbo parowej znajduje zastosowanie w badaniach diagnostycznych zarówno samych wymienników jak i całego systemu elektrowni.
-
Wytwarzanie wzorcowych mieszanin gazowych za pomocą generatora pneumatycznegoGeneration of standard gaseous mixtures using pneumatic generator
PublicationW pracy przedstawiono konstrukcję pneumatycznego generatora wzorcowych mieszanin gazowych przeznaczonych do kalibracji różnych analizatorów gazów. Generator może także być wykorzystany do wytwarzania mieszanin oddechowych dla nurków pracujących na różnych głębokościach. Błąd bezwzględny wykonania mieszanin dwuskładnikowych i trójskładnikowych za pomocą skonstruowanego generatora nie przekracza 2%.
-
INTERNATIONAL JOURNAL OF TURBO & JET-ENGINES
Journals -
Implementation complexity analysis of the turbo decoding algorithms on digital signal processor
Publication -
Performance of data transmission in UMTS with turbo code about decreased number of states
PublicationIn the paper a structure of turbo encoder and decoder about decreased number of states has been described. The simulation results of transmission performance based on turbo coding without the reduction of the number of iterations for the uplink and downlink of WCDMA/FDD interface have been presented. The SOVA algorithm for turbo decoding has been used. The investigations have been carried out for Outdoor to Indoor & Pedestrian...
-
Performance analysis of data transmission in MC-CDMA radio interface with turbo codes
PublicationMulti-carrier code division multiple access (MC-CDMA) technique is a combination of two radio access techniques: CDMA and orthogonal frequency division multiplexing and has the advantages of both techniques. The paper presents the design of transmitter and receiver for MC-CDMA radio interface. It also presents encoders and decoders of turbo codes which were used in simulation of the MC-CDMA technique. Two turbo codes with 8-state...
-
Digital image transmission simulation using the PL-log-MAP turbo decoding algorithm
Publication -
Michał Michna dr hab. inż.
PeopleMichal Michna received the M.Sc. and Ph.D. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 1998 and 2005, respectively. Since 2004, he was employed at the Department of Power Electronics and Electrical Machines of the Gdańsk University of Technology (assistant, assistant professor, senior lecturer). In 2010-2015 he was a deputy of head of the Department of Power Electronics and...
-
Chapter 7 : Optimisation of streamwise vortex generator
PublicationW pracy przedstawiono analizę struktury przepływu generatora wirów wzdłużnych. Wyniki obliczeń trówjymiarowych porównano z wynikami badań eksperymentalnych.