Tomasz Kocejko - Publikacje - MOST Wiedzy

Wyszukiwarka

Filtry

wszystkich: 68

  • Kategoria
  • Rok
  • Opcje

wyczyść Filtry wybranego katalogu niedostępne

Katalog Publikacji

Rok 2025
  • Follow-up assessment of the microvascular function in patients with long COVID
    Publikacja
    • M. Romanowska-Kocejko
    • A. Braczko
    • A. Jędrzejewska
    • M. Żarczyńska-Buchowiecka
    • T. Kocejko
    • B. Kutryb-zając
    • M. Hellmann

    - MICROVASCULAR RESEARCH - Rok 2025

    Long COVID is a complex pathophysiological condition. However, accumulating data suggests that COVID-19 is a systemic microvascular endothelial dysfunction with different clinical manifestations. In this study, a microvascular function was assessed in long COVID patients (n = 33) and healthy controls (n = 30) using flow-mediated skin fluorescence technique (FMSF), based on measurements of nicotinamide adenine dinucleotide fluorescence...

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2024
  • Continuous Biomedical Monitoring in VR Scenarios of Socially Smart and Safe Autonomous Vehicle Interaction
    Publikacja

    - Rok 2024

    Pedestrians, as vulnerable road users, pose safety challenges for autonomous vehicles (AVs). Their behavior, often unpredictable and subject to change, complicates AV-pedestrian interactions. To address this uncertainty, AV s can enhance safety by communicating their planned trajectories to pedestrians. In this research, we explore the interaction between pedestrians and autonomous vehicles within an industrial environment, focusing...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Evaluating the Use of Edge Device Towards Fall Detection in Smart City Environment
    Publikacja

    - Rok 2024

    This paper presents the development and preliminary testing of a fall detection algorithm that leverages OpenPose for real-time human pose estimation from video feeds. The system is designed to function optimally within a range of up to 7 meters from ground-level cameras, focusing exclusively on detected human silhouettes to enhance processing efficiency. The performance of the proposed approach was evaluated using accuracy values...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Evaluating the Use of Edge Devices for Detection and Tracking of Vehicles in Smart City Environment
    Publikacja

    - Rok 2024

    This paper introduces a Smart City solution designed to run on edge devices, leveraging NVIDIA's DeepStream SDK for efficient urban surveillance. We evaluate five object-tracking approaches, using YOLO as the baseline detector and integrating three Nvidia DeepStream trackers: IOU, NvSORT, and NvDCF. Additionally, we propose a custom tracker based on Optical Flow and Kalman filtering. The presented approach combines advanced machine...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • How Integration of a Brain-Machine Interface and Obstacle Detection System Can Improve Wheelchair Control via Movement Image
    Publikacja
    • T. Kocejko
    • N. Matuszkiewicz
    • J. Kwiatkowski
    • P. Durawa
    • A. Madajczak

    - SENSORS - Rok 2024

    This study presents a human-computer interaction combined with a brain-machine interface (BMI) and obstacle detection system for remote control of a wheeled robot through movement imagery, providing a potential solution for individuals facing challenges with conventional vehicle operation. The primary focus of this work is the classification of surface EEG signals related to mental activity when envisioning movement and deep relaxation...

    Pełny tekst do pobrania w portalu

  • Pulse Transit Time - Fiducial Points Accuracy Determination as Examined by Means of Synthetic Signals

    There are many approaches to non-invasively deter-mine blood pressure. Among them there are methods based on utilizing pulse transit time measured by means of photoplethys-mography. The variability of the blood pressure drop between two measurement sensors placed along the artery and its dependence on the selected parameters describing the cardiovascular system is presented in the paper. This pressure drop modifies the pressure...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Real-Time Skin Quality Assessment System
    Publikacja

    - Rok 2024

    This thesis presents a real-time skin assessment system with the main aim of detecting inflammatory acne lesions and tracking skin conditions. A facial acne lesion detection algorithm was developed, using a pre-trained YOLOv8 model for lesion detection and a Mediapipe detector for face detection. The proposed solution aims to create a system used in smart mirrors to help users self-monitor and monitor their skin condition in real...

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2023
Rok 2022
  • Deep learning approach on surface EEG based Brain Computer Interface
    Publikacja

    - Rok 2022

    In this work we analysed the application of con-volutional neural networks in motor imagery classification for the Brain Computer Interface (BCI) purposes. To increase the accuracy of classification we proposed the solution that combines the Common Spatial Pattern (CSP) with convolutional network (ConvNet). The electroencephalography (EEG) is one of the modalities we try to use for controlling the prosthetic arm. Therefor in this...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Educational Dataset of Handheld Doppler Blood Flow Recordings
    Publikacja

    - Rok 2022

    Vital signals registration plays a significant role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomena as well learn how to correctly process and interpret the data. This dataset was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly acquired signals as well as the basic methods of signal processing. This...

    Pełny tekst do pobrania w portalu

  • Eye-tracking everywhere - software supporting disabled people in interaction with computers
    Publikacja

    - Rok 2022

    In this paper we present comprehensive system for communication with computer by gaze. One of the main assumptions behind this work was to provide solution that can be used with standard RGB webcam. The proposed comprehensive system included the eye tracking module and user interface for convenient gaze interaction with computer. As a result a fully functional application was developed. The average accuracy of the eye tracking...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Using Convolutional Neural Networks for Corneal Arcus Detection Towards Familial Hypercholesterolemia Screening
    Publikacja

    Familial hypercholesterolemia (FH) is a highly undiagnosed disease. Among FH patients, the onset of premature coronary artery disease is 13 times higher than in the general population. Early diagnosis and treatment is essential to prevent cardiovascular diseases and their complications, and to prolong life. One of the clinical criteria of FH is the occurrence of a corneal arcus (CA) among patients, especially those under 45 years...

    Pełny tekst do pobrania w portalu

  • Using Disparity Map for Moving Object Position Estimation in Pan Tilt Camera Images
    Publikacja

    - Rok 2022

    In this paper we present the algorithm for rapid moving object position estimation in an images acquired from pan tilt camera. Detection of a moving object in a image acquired from a moving camera might be quite challenging. Standard methods that relay on analyzing two consecutive frames are not applicable due to the changing background. To overtake this problem we decided to evaluate the possibility of calculating a disparity...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Using Synchronously Registered Biosignals Dataset for Teaching Basics of Medical Data Analysis – Case Study
    Publikacja

    - Rok 2022

    Medical data analysis and processing strongly relies on the data quality itself. The correct data registration allows many unnecessary steps in data processing to be avoided. Moreover, it takes a certain amount of experience to acquire data that can produce replicable results. Because consistency is crucial in the teaching process, students have access to pre-recorded real data without the necessity of using additional equipment...

    Pełny tekst do pobrania w portalu

Rok 2021
  • Influence of preprocessing techniques on pulse pressure velocity determination

    Pulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • THE ROLE OF INFERENCE IN MOBILE MEDICAL APPLICATION DESIGN
    Publikacja

    - Rok 2021

    In the early 21st century, artificial intelligence began to be used to process medical information. However, before this happened, predictive models used in healthcare could only consider a limited number of variables, and only in properly structured and organised medical data. Today, advanced tools based on machine learning techniques - which, using artificial neural networks, can explore extremely complex relationships - and...

  • Using deep learning to increase accuracy of gaze controlled prosthetic arm
    Publikacja

    - Rok 2021

    This paper presents how neural networks can be utilized to improve the accuracy of reach and grab functionality of hybrid prosthetic arm with eye tracing interface. The LSTM based Autoencoder was introduced to overcome the problem of lack of accuracy of the gaze tracking modality in this hybrid interface. The gaze based interaction strongly depends on the eye tracking hardware. In this paper it was presented how the overall the...

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2020
Rok 2019
Rok 2018
Rok 2017
  • A body position influence on ECG derived respiration

    An influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Extending touch-less interaction with smart glasses by implementing EMG module

    In this paper we propose to use temporal muscle contraction to perform certain actions. Method: The set of muscle contractions corresponding to one of three actions including “single-click”, “double-click” “click-n-hold” and “non-action” were recorded. After recording certain amount of signals, the set of five parameters was calculated. These parameters served as an input matrix for the neural network. Two-layer feedforward neural...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The role of EMG module in hybrid interface of prosthetic arm

    Nearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Using wearable device for biomedical signal acquisition and processing

    In this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2016

wyświetlono 2850 razy