Improving the CPX method by specifying reference tyres and including corrections for rubber hardnes and temperature - Publikacja - MOST Wiedzy

Wyszukiwarka

Improving the CPX method by specifying reference tyres and including corrections for rubber hardnes and temperature

Abstrakt

Recently completed work in the EU project ROSANNE and in working group ISO/TC43/SC1/WG33 has allowed substantial improvements to measurements made by the Close-Proximity (CPX) method, intended for measurement of noise properties of road surfaces.The paper summarizes the experimental work and describes the conclusions and implementation in ISO/FDIS 11819-2 (CPX method) and in the supporting ISO (draft) Technical Specifications 11819-3 about Reference Tyres and 13471-1 about Temperature Corrections.In the Reference Tyre Specification, two reference tyres are defined, of which one is the 16” SRTT specified in ASTM 2493-14 and the other is a commercial light truck tyre. Both tyres have been tested with respect to correlations with SPB (pass-by) measurements and found to represent car and truck tyres, respectively, in this particular application. To account for reasonable ageing and minor production differences, a correction for rubber hardness is specified, in order to normalize measurement results to tyres having reference hardness.The Temperature Correction Specification includes temperature coefficients that can be used for normalizing noise levels to an air reference temperature of 20 degrees C. The coefficients relate to driving speed by a simple equation which is different for three categories of road surfaces, which are specified in the document.

Autorzy (5)

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Aktywność konferencyjna
Typ:
publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
Tytuł wydania:
Proceedings of the INTER-NOISE 2016 45th International Congress and Exposition on Noise Control Engineering :Towards a Quieter Future strony 4913 - 4923
ISSN:
0105-175x
Język:
angielski
Rok wydania:
2016
Opis bibliograficzny:
Sandbegr U., Buhlmann E., Conter M., Mioduszewski P., Wehr R.: Improving the CPX method by specifying reference tyres and including corrections for rubber hardnes and temperature // Proceedings of the INTER-NOISE 2016 45th International Congress and Exposition on Noise Control Engineering :Towards a Quieter Future/ ed. Wolfgang Kropp, Otto von Estorff, Brigitte Schulte-Fortkamp Berlin: German Acoustical Society (DEGA), 2016, s.4913-4923
Weryfikacja:
Politechnika Gdańska

wyświetlono 142 razy

Publikacje, które mogą cię zainteresować

Meta Tagi