Filtry
wszystkich: 3988
wybranych: 558
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: NON- -CONTROLLABLE VARIABLE
-
Data from the survey on Gdańsk University of Technology graduates' assessment of studying - the year 2017
Dane BadawczeThe dataset includes data from the survey on Gdańsk University of Technology graduates’ assessment of studying. The research refers to graduates from the year 2017. The survey was conducted in 2019, two years after the respondents obtained graduate status. The research sample included 1594 respondents. The study referred to as i.a. assessment of whether...
-
Data from the survey on Gdańsk University of Technology graduates' assessment of studying - the year 2018
Dane BadawczeThe dataset includes data from the survey on Gdańsk University of Technology graduates’ assessment of studying. The research refers to graduates from the year 2018. The survey was conducted in 2020, two years after the respondents obtained graduate status. The research sample included 727 respondents. The study referred to as i.a. assessment of whether...
-
Data from the survey on Gdańsk University of Technology graduates' assessment of studying - the year 2016
Dane BadawczeThe dataset includes data from the survey on Gdańsk University of Technology graduates’ assessment of studying. The research refers to graduates from the year 2016. The survey was conducted in 2018, two years after the respondents obtained graduate status. The research sample included 1947 respondents. The study referred to as i.a. assessment of whether...
-
SEM micrographs and photos of salivary gland stones
Dane BadawczeThis dataset contains SEM micrographs and high-resolution photographs taken for salivary gland stones (sialolith) extracted during joint studies between Medical University of Gdansk and Gdansk University of Technology.
-
Data from the survey on Gdańsk University of Technology graduates' assessment of studying - the year 2015
Dane BadawczeThe dataset includes data from the survey on Gdańsk University of Technology graduates’ assessment of studying. The research refers to graduates from the year 2015. The survey was conducted in 2017, two years after the respondents obtained graduate status. The research sample included 2553 respondents. The study referred to as i.a. assessment of whether...
-
Data from the survey on Gdańsk University of Technology graduates' qualifications development - the year 2017
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology graduates’ qualifications development. The research refers to graduates from the year 2017. The survey was conducted in 2019, two years after the respondents obtained graduate status. The research sample included 1594 respondents. The study referred to as i.a. to examine...
-
Data from the survey on Gdańsk University of Technology graduates' professional careers - the year 2015
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology graduates’ professional careers, from the year 2015. The survey was conducted in 2017, two years after the respondents obtained graduate status. The research sample included 2553 respondents. The study concerned i.a. the percentage of people working among graduates of the...
-
Data from the survey on Gdańsk University of Technology graduates' qualifications development - the year 2016
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology graduates’ qualifications development. The research refers to graduates from the year 2016. The survey was conducted in 2018, two years after the respondents obtained graduate status. The research sample included 1947 respondents. The study referred to as i.a. to examine...
-
Data from the survey on Gdańsk University of Technology graduates' qualifications development - the year 2015
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology graduates’ qualifications development. The research refers to graduates from the year 2015. The survey was conducted in 2017, two years after the respondents obtained graduate status. The research sample included 2553 respondents. The study referred to as i.a. to examine...
-
Data from the survey on Gdańsk University of Technology graduates' professional careers - the year 2016
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology graduates’ professional careers, from the year 2016. The survey was conducted in 2018, two years after the respondents obtained graduate status. The research sample included 1947 respondents. The study concerned i.a. the percentage of people working among graduates of the...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....