Filtry
wszystkich: 16579
-
Katalog
- Publikacje 14041 wyników po odfiltrowaniu
- Czasopisma 415 wyników po odfiltrowaniu
- Konferencje 33 wyników po odfiltrowaniu
- Osoby 280 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 35 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 8 wyników po odfiltrowaniu
- Kursy Online 386 wyników po odfiltrowaniu
- Wydarzenia 10 wyników po odfiltrowaniu
- Dane Badawcze 1369 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: STRUCTURAL POUNDING · EARTHQUAKES · SOIL-STRUCTURE INTERACTION · EQUAL HEIGHT BUILDINGS · NONLINEAR VISCOELASTIC MODEL · ENERGY DISSIPATED
-
Earthquake-induced pounding between equal height multi-storey buildings considering soil-structure interaction
PublikacjaThe present paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated equal height buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using a suit of ground motions with different peak...
-
Incremental dynamic analysis and fragility assessment of buildings founded on different soil types experiencing structural pounding during earthquakes
PublikacjaThe effect of the soil type on buildings experiencing pounding during earthquakes is investigated in this study using the incremental dynamic analysis and fragility assessment methods. Three 3-D structures with different number of storeys (4, 6 and 8) were considered in this study. Three pounding scenarios between these three buildings were taken into account, i.e. pounding between 4-storey and 6-storey buildings, between 4-storey...
-
Analysis of floor-to-column pounding of buildings founded on different soil types
PublikacjaThe aim of this study is to investigate the effect of the soil type on buildings experiencing floor-to-column pounding during earthquakes. Five buildings with 4-storeys, 6-storeys, and 7-storeys were considered. Three types of the 4-storey building with different total heights were taken into account which leads to floor-to-column pounding at 1/3, 1/2 and 2/3 of the height of the impacted column. Two pounding scenarios were considered,...
-
Behaviour of Colliding Multi-Storey Buildings under Earthquake Excitation Considering Soil-Structure Interaction
PublikacjaThis paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using the time history of the Kobe earthquake of 1995. A nonlinear...
-
Pounding between high-rise buildings founded on different soil types
PublikacjaEarthquake-induced pounding is a phenomenon that has been often experienced in previous earthquakes. The aim of this study is to investigate the effect of the soil type on high-rise buildings experiencing earthquake induced-pounding. Pounding between 7-storey and 9-storey buildings is examined under five soil types defined in the ASCE 7-10 code which are hard rock, rock, very dense soil and soft rock, stiff soil and soft clay soil....
-
Linking of adjacent three-storey buildings for mitigation of structural pounding during earthquakes
PublikacjaThe reports after major earthquakes indicate that the earthquake-induced pounding between insufficiently separated buildings may lead to significant damage or even total collapse of structures. An intensive study has recently been carried out on mitigation of pounding hazards so as to minimize the structural damages or prevent collisions at all. The aim of this paper is to investigate the effectiveness of the method when two adjacent...
-
Effect of soil on the capacity of viscous dampers between adjacent buildings
PublikacjaThis study investigated the seismic pounding of two adjacent buildings considering soil–structure interaction (SSI). A comprehensive parametric study of buildings with different heights was performed to reveal the pounding-involved behaviour considering the soil effect. Wavelet transform has been conducted to gain insight into the differences in the frequency contents of the impact forces between fixed- and flexible-base adjacent...
-
Influence of soil–structure interaction on seismic pounding between steel frame buildings considering the effect of infill panels
PublikacjaThe present research aims to study the influence of the soil-structure interaction (SSI) and existence or absence of masonry infill panels in steel frame structures on the earthquake-induced pounding-involved response of adjacent buildings. The study was further extended to compare the pounding-involved behavior versus the independent behavior of structures without collisions, focusing much on dynamic behavior of single frames....
-
Analysis of pounding between adjacent buildings founded on different soil types
PublikacjaEarthquake-induced pounding was experienced in many previous earthquakes and it was found to be a critical issue. This study investigates the effect of pounding between buildings founded on the same and different soil types. Three 3-D buildings with 4, 6 and 8 storeys were considered in this study. Three pounding scenarios were taken into account, i.e. pounding between 4-storey and 6-storey buildings, between 4-storey and 8-storey...
-
Seismic gap between buildings founded on different soil types experiencing pounding during earthquakes
PublikacjaSeveral formulas have been suggested in the literature to evaluate the minimum seismic gap that would prevent collisions between adjacent buildings during earthquakes, including those based on the absolute sum of the peak displacements (ABS), square root of the sum of the squares (SRSS), the double difference method (DDC), Australian code, and approach proposed by Naderpour et al. The aim of the present study is to evaluate the...
-
Nonlinear numerical simulation of earthquake-induced pounding between timber frame buildings
PublikacjaEarthquakes may induce serious dynamic loads acting on buildings, which can lead to damage or even destruction of the whole structure. In densely populated areas, it is quite common that buildings are located very close one to another which can result in pounding between them during ground motions. Due to the environmental awareness, multi-story timber frame buildings are gaining popularity and therefore there is a need to investigate...
-
Predicting the peak structural displacement preventing pounding of buildings during earthquakes
PublikacjaThe aim of the present paper is to verify the effectiveness of the artificial neural network (ANN) in predicting the peak lateral displacement of multi-story building during earthquakes, based on the peak ground acceleration (PGA) and building parameters. For the purpose of the study, the lumped-mass multi-degree-of-freedom structural model and different earthquake records have been considered. Firstly, values of stories mass and...
-
Mitigating the seismic pounding of multi-story buildings in series using linear and nonlinear fluid viscous dampers
PublikacjaSeismic-induced pounding between adjacent buildings may have serious consequences, ranging from minor damage up to total collapse. Therefore, researchers try to mitigate the pounding problem using different methods, such as coupling the adjacent buildings with stiff beams, connecting them by using viscoelastic links, and installing damping devices in each building individually. In the current paper, the effect of using linear and...
-
Verification of Formulas for Periods of Adjacent Buildings Used to Assess Minimum Separation Gap Preventing Structural Pounding during Earthquakes
PublikacjaInsufficient separation distance between adjacent buildings may lead to serious damages during earthquakes due to structural pounding. The best way to prevent collisions is to provide sufficiently large separation distance between the structures. In this paper, the periods of two closely-spaced linear and nonlinear buildings have been investigated so as to accurately assess the minimum in-between separation gap. A new equation...
-
Non-linear strain rate analysis of earthquake-induced pounding between steel buildings
PublikacjaPast and recent earthquakes have shown that ground motions may cause severe structural damage to civil engineering structures. Earthquake-induced pounding between adjacent buildings has been identified as one of the reasons which intensifies damages. The aim of this paper is to show the results of the detailed nonlinear FEM analysis of earthquake-induced pounding between two steel buildings. The elastic – perfectly plastic material...
-
Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings
PublikacjaDuring earthquakes, out-of-phase vibrations in adjacent buildings with limited distance may cause pounding between them. In recent years, the use of seismic isolation has expanded considerably as an effective approach to reduce seismic damage. However, the isolated building experiences large displacements during earthquakes, and there is a possibility of collisions with adjacent structures. The research on earthquake-induced pounding...
-
Application of discrete wavelet transform in seismic nonlinear analysis of soil–structure interaction problems
PublikacjaSimulation of soil-structure interaction (SSI) effects is a time-consuming and costly process. However, ignoring the influence of SSI on structural response may lead to inaccurate results, especially in the case of seismic nonlinear analysis. In this paper, wavelet transform methodology has been utilized for investigation of the seismic response of soil-structure systems. For this purpose, different storey outrigger braced buildings...
-
Study on polymer elements for mitigation of earthquake-induced pounding between buildings in complex arrangements
PublikacjaPounding between neighbouring buildings during earthquakes has been identified as one of the reasons for substantial damage or even total collapse of colliding structures, so it has been the subject of numerous studies in the recent years. A major reason leading to interactions between adjacent, insufficiently separated structures results from the differences in their dynamic properties. The problem is much more complicated for...
-
Predicting the seismic collapse capacity of adjacent SMRFs retrofitted with fluid viscous dampers in pounding condition
PublikacjaSevere damages of adjacent structures due to structural pounding during earthquakes have emphasized the need to use some seismic retrofit strategy to enhance the structural performance. The purpose of this paper is to study the influence of using linear and nonlinear Fluid Viscous Dampers (FVDs) on the seismic collapse capacities of adjacent structures prone to pounding and proposing modification factors to modify the median...
-
Predicting the seismic collapse capacity of adjacent SMRFs retrofitted with fluid viscous dampers in pounding condition
PublikacjaSevere damages of adjacent structures due to structural pounding during earthquakes have emphasized the need to use some seismic retrofit strategy to enhance the structural performance. The purpose of this paper is to study the influence of using linear and nonlinear Fluid Viscous Dampers (FVDs) on the seismic collapse capacities of adjacent structures prone to pounding and proposing modification factors to modify the median...
-
Effective Equations for the Optimum Seismic Gap Preventing Earthquake-Induced Pounding between Adjacent Buildings Founded on Different Soil Types
PublikacjaThe best approach to avoid collisions between adjacent structures during earthquakes is to provide sufficient spacing between them. However, the existing formulas for calculating the optimum seismic gap preventing pounding were found to provide inaccurate results upon the consideration of different soil types. The aim of this paper is to propose new equations for the evaluation of the sufficient in-between separation gap for buildings...
-
Shaking table experimental study on pounding between adjacent structures founded on different soil types
PublikacjaThe aim of this study is to extensively investigate the effect of the soil type on the response of colliding structures based on shaking table experimental tests. Two single-storey models of steel buildings with different dynamic parameters were considered in this study. Three pounding scenarios were taken into account by applying different seismic gaps (0.5 cm, 1 cm and 1.5 cm as well as the no pounding case). First, the effect...
-
An ANN-Based Approach for Prediction of Sufficient Seismic Gap between Adjacent Buildings Prone to Earthquake-Induced Pounding
PublikacjaEarthquake-induced structural pounding may cause major damages to structures, and therefore it should be prevented. This study is focused on using an artificial neural network (ANN) method to determine the sufficient seismic gap in order to avoid collisions between two adjacent buildings during seismic excitations. Six lumped mass models of structures with a different number of stories (from one to six) have been considered in...
-
Seismic pounding behavior of multi-story buildings in series considering the effect of infill panels
PublikacjaThe aim of the present paper is to study the influence of the infill panels on the seismic pounding response of adjacent structures in series. The contribution of the masonry infill has been simulated using equivalent diagonal compression struts. Steel frames have been assumed to have elastic-plastic behavior with 1% linear strain hardening. The dynamic contact analysis has been utilized where contact surface model (target and...
-
Simulation of the response of base-isolated buildings under earthquake excitations considering soil flexibility
PublikacjaThe accurate analysis of the seismic response of isolated structures requires the incorporation of the flexibility of supporting soil. However, it is often customary to idealize the soil as rigid during the analysis of such structures. In the present paper, seismic response time history analyses of base-isolated buildings modelled as single degree-of-freedom (SDOF) and multi degree-of-freedom (MDOF) systems with linear and nonlinear...
-
Optimal retrofit strategy using viscous dampers between adjacent RC and SMRFs prone to earthquake‑induced pounding
PublikacjaNowadays, retrofitting-damaged buildings is an important challenge for engineers. Finding the optimal placement of Viscous Dampers (VDs) between adjacent structures prone to earthquake-induced pounding can help designers to implement VDs with optimizing the cost of construction and achieving higher performance levels for both structures. In this research, the optimal placement of linear and nonlinear VDs between the 3-story, 5-story,...
-
Linear viscoelastic modelling of damage-involved structural pounding during earthquakes
PublikacjaDamage-involved structural pounding during earthquakes has been recently intensively studied using different impact force models. The results of the previous studies indicate that the linear viscoelastic model is relatively simple yet accurate in modelling pounding-involved behaviour of structures during earthquakes. The only shortcoming of the model is a negative value of the pounding force occurring just before separation, which...
-
Modified linear viscoelastic model of earthquake-induced structural pounding
PublikacjaIn recent times, earthquake-induced structural pounding has been intensively studied through the use of different impact force models. The numerical results obtained from the previous studies indicate that the linear viscoelastic model is relatively simple and accurate in modeling pounding-involved behavior of structures during earthquakes. The only shortcoming of the model is a negative value of the pounding force occurring just...
-
Determination of Peak Impact Force for Buildings Exposed to Structural Pounding during Earthquakes
PublikacjaStructural pounding between adjacent, insufficiently separated buildings, or bridge segments, has been repeatedly observed during seismic excitations. Such earthquake-induced collisions may cause severe structural damage or even lead to the collapse of colliding structures. The aim of the present paper was to show the results of the study focused on determination of peak impact forces during collisions between buildings exposed...
-
Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures
PublikacjaStructural pounding has been observed in many previous earthquakes due to insufficient gap commonly provided between adjacent structures. The collisions usually generate large impact forces and short duration acceleration pulses which may result in significant damage to the colliding buildings. Because of that, earthquake induced structural pounding has been intensively studied and investigated for the last three decades. Results...
-
Building damage due to structural pounding during earthquakes
PublikacjaEarthquake-induced pounding between adjacent buildings has been identified as one of the reasons for substantial damage or even total collapse of colliding structures. A major reason leading to interactions in buildings results from the differences in their dynamic parameters and also from insufficient distance between the structures. Although the research on structural pounding has been much advanced, the studies have mainly been...
-
Pounding between high-rise buildings with different structural arrangements
PublikacjaEarthquake-induced structural pounding has led to significant damages during previous earthquakes. This paper investigates the effect of pounding on the dynamic response of colliding high-rise buildings with different structural arrangements. Three 3-D buildings are considered in the study, including 5-storey building, 7-storey building and 9-storey building. Three pounding scenarios are also taken into account, i.e. pounding between...
-
Pounding of structures during earthquakes modelled by nonlinear viscoelastic impact element.
PublikacjaAnalizowano zderzenia konstrukcji budowlanych podczas trzęsień ziemi wykorzystując model lepkosprężysty siły zderzenia. W analizie, zachowanie konstrukcji o różnych własnościach dynamicznych symulowane jest modelem dyskretnym o skupionych masach. wyniki badań pokazują, iż zderzenie może prowadzić do znacznego wzrostu odpowiedzi konstrukcji mniej sztywnej i lżejszej.
-
Soil-structure interaction effects on modal parameters of office buildings with different number of stories
PublikacjaThe paper summarizes the results of a numerical investigation designed to study the soil-structure interaction effects on modal parameters of three office buildings. The reinforced-concrete 4-storey, 8-storey, and 12-storey office buildings, each with additional two levels of embedded basements, represent low, medium, and high-rise structures, respectively. In order to conduct this research, detailed finite-element structure models...
-
Incremental Dynamic Analysis and Fragility Assessment of Buildings with Different Structural Arrangements Experiencing Earthquake-Induced Structural Pounding
PublikacjaStructural pounding is considered as one of the most critical phenomena occurring during earthquakes. This paper presents the incremental dynamic analysis and fragility assessment of buildings experiencing earthquake-induced pounding. Three 3-D buildings with different number of storeys and under different structural arrangements have been considered. Three pounding scenarios have been taken into account, i.e. pounding between...
-
Torsional earthquake-induced pounding between adjacent buildings founded on different soil types
PublikacjaThis paper investigates the effect of the soil type on the torsional response of build- ings experiencing torsional pounding due to earthquake excitations. Six buildings (one 4-storey building and five 6-storey buildings) with different configurations have been considered. First, pounding between different structures has been analysed for a specified soil type and the effect of the torsional pounding and the contact asymmetry on...
-
Earthquake-induced pounding between equal height buildings with substantially different dynamic properties
PublikacjaZderzenia pomiędzy konstrukcjami budowlanymi podczas trzęsień ziemi mogą prowadzić do znacznych uszkodzeń czy nawet całkowitego zniszczenia. Celem niniejszego artykuły jest analiza zderzeń pomiędzy budynkami o jednakowej wysokości i różnych parametrach dynamicznych. W artykule przedstawiono wyniki badań numerycznych przeprowadzonych na nieliniowych modelach dyskretnych o skupionych masach z wykorzystaniem nieliniowego modelu lepkosprężystego...
-
Analysis of the effect of the seismic gap on the response of buildings experiencing pounding during earthquakes
PublikacjaThe aim of this paper is to investigate the effect of the seismic gap on the dynamic response of buildings experiencing earthquake-induced pounding. Three buildings have been analysed, which are 5-storey, 7-storey and 9-storey structures. Three possible pounding scenarios have been considered, which are pounding between 5-storey and 7-storey buildings, pounding between 5-storey and 9-storey buildings and pounding between 7-storey...
-
Probabilistic assessment of SMRFs with infill masonry walls incorporating nonlinear soil-structure interaction
PublikacjaInfill Masonry Walls (IMWs) are used in the perimeter of a building to separate the inner and outer space. IMWs may affect the lateral behavior of buildings, while they are different from those partition walls that separate two inner spaces. This study focused on the seismic vulnerability assessment of Steel Moment-Resisting Frames (SMRFs) assuming different placement of IMWs incorporating nonlinear Soil-Structure Interaction (SSI)....
-
Effective Gap Size Index for Determination of Optimum Separation Distance Preventing Pounding between Buildings during Earthquakes
PublikacjaSeismic excitations may lead to collisions between adjacent civil engineering structures causing major damage. In this paper, an effective equation for calculating the gap size index is proposed so as to provide the optimum separation distance preventing structural pounding during different earthquakes. Evaluation of the best prediction of the required separation distance between two adjacent buildings was carried out by using...
-
Enhancing seismic performance of rigid and semi-rigid connections equipped with SMA bolts incorporating nonlinear soil-structure interaction
PublikacjaNowadays, using smart connections can improve the performance of buildings with some recentering features that are from the superelastic behavior of Shape Memory Alloys (SMAs). It seems that there is different rigidity between the designed connection and the real one in Steel Moment-Resisting Frames (SMRFs), which can be considered as a problematic issue due to the importance of connections in seismic performance assessment. This...
-
Earthquake-Induced Structural Pounding
PublikacjaEarthquake-induced structural pounding between insufficiently separated build-ings, or bridge segments, has been repeatedly observed during ground motions. The reports after earthquakes indicate that it may lead to some local damage in the case of moderate seismic events or may result in considerable destruction or even collapse of colliding structures during severe ground motions. Pounding in build-ings is usually caused by the...
-
Enhancing Seismic Performance of Semi-rigid Connection Using Shape Memory Alloy Bolts Considering Nonlinear Soil–Structure Interaction
PublikacjaSteel Moment-Resisting Frames (SMRFs) have their lateral resistance for their rigid connections, while real conditions have shown that the rigidity of a connection depends on the bolts and the end-plate thickness, which may not provide the assumed rigidity in design process. In this research, the main goal is to enhance the semi-rigid connections using shape memory alloy (SMA) bolts and explore their effects on the seismic limit-state...
-
Fragility analysis of structural pounding between adjacent structures arranged in series with various alignment configurations under near‑field earthquakes
PublikacjaA major cause of local to total damages is related to structural pounding in a large number of past earthquakes. In general, these collisions take place as a result of differences in the dynamic characteristics of the colliding structures. To acquire a better perception of the behavior of structures, in this paper, three structures featuring different heights are modeled in series and with various configurations next to each other...
-
ENERGY AND BUILDINGS
Czasopisma -
Experimental Study on Pounding between Structures during Damaging Earthquakes
PublikacjaMutual pounding between structures during earthquakes may cause serious structural damage. The aim of this paper is to show the results of a shaking table experimental study focused on pounding between structures in series under several earthquake excitations. The experiments were performed using three tower models with different configurations and different gap distances between them. In the first stage of the study, one rigid...
-
Theoretical and experimental assessment of parameters for the non-linear viscoelastic model of structural pounding
PublikacjaZjawisko zderzeń pomiędzy sąsiednimi konstrukcjami budowlanymi podczas trzęsień ziemi jest w ostatnim czasie intensywnie badane z wykorzystaniem różnych modeli numerycznych siły zderzenia w czasie kontaktu. Wyniki badań eksperymentalnych pokazują, iż nieliniowy model lepko-sprężysty jest najdokładniejszy wśród modeli stosowanych do analizy. Model ten zdefiniowany jest poprzez dwa parametry: liczbę tłumienia zderzenia oraz parametr...
-
Effective Formula for Impact Damping Ratio for Simulation of Earthquake-induced Structural Pounding
PublikacjaStructural pounding during earthquakes may cause substantial damage to colliding structures. The phenomenon is numerically studied using different models of collisions. The aim of the present paper is to propose an effective formula for the impact damping ratio, as a parameter of the impact force model used to study different problems of structural pounding under seismic excitations. Its accuracy has been verified by four various...
-
Damage-Involved Structural Pounding in Bridges under Seismic Excitation
PublikacjaDuring severe earthquakes, pounding between adjacent superstructure segments of highway elevated bridges was often observed. It is usually caused by the seismic wave propagation effect and may lead to significant damage. The aim of the present paper is to show the results of the numerical analysis focused on damage-involved pounding between neighbouring decks of an elevated bridge under seismic excitation. The analysis was carried...
-
Pounding between Inelastic Three-Storey Buildings under Seismic Excitations
PublikacjaStructural interactions between adjacent, insufficiently separated buildings have been repeatedly observed during damaging ground motions. This phenomenon, known as the structural pounding, may result in substantial damage or even total collapse of structures. The aim of the present paper is to show the results of the nonlinear numerical analysis focused on pounding between inelastic three-storey buildings under seismic excitations....