Wyniki wyszukiwania dla: OPTICAL COHERENCE TOMOGRAPHY, MAGNETIC RESONANCE IMAGING
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublikacjaBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publikacja -
Polarization sensitive optical coherence tomography for technical materials investigation
PublikacjaZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
An Optical Low-Coherence System for 2-Dimensional Visualization of Thin Polymer Layers
PublikacjaW artykule omówiono zasadę działania i przedstawiono podstawowe właściwości systemu OCT (Optical Coherence Tomography). Na przykładzie folii polietylenowej przedyskutowano możliwości wykorzystania systemu do badanie wewnętrznej struktury warstwowej obiektów niebiologicznych. Przedstawiono i omówiono wyniki przeprowadzonych badań nad warstwowymi materiałami przeźroczystymi.
-
Smart Approach for Glioma Segmentation in Magnetic Resonance Imaging using Modified Convolutional Network Architecture (U-NET)
PublikacjaSegmentation of a brain tumor from magnetic resonance multimodal images is a challenging task in the field of medical imaging. The vast diversity in potential target regions, appearance and multifarious intensity threshold levels of various tumor types are few of the major factors that affect segmentation results. An accurate diagnosis and its treatment demand strict delineation of the tumor affected tissues. Herein, we focus on...
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublikacjaW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublikacjaDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Małgorzata Szczerska prof. dr hab. inż.
Osoby -
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Magnetic Resonance
Czasopisma -
Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
Publikacja -
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublikacjaPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
Non invasive optical cellular imaging in humans.
PublikacjaOne of the most appealing and still unsolved problems in biological and medical imaging is the possibility of noninvasive visualization of tissue in vivo with an accuracy of microscopic examination. A major difficulty to solve in biomedical imaging is a degradation of image quality caused by the presence of optical inhomogeneity of tissue. Is there any chance to develop a microscopic method that allows non-invasive observation...
-
MAGNETIC RESONANCE IMAGING
Czasopisma -
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublikacjaMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter
Publikacja -
Magnetic Resonance Imaging Clinics of North America
Czasopisma -
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublikacjaIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Magnetic Resonance Insights
Czasopisma -
Magnetic Resonance in Solids
Czasopisma