Filtry
wszystkich: 10
Wyniki wyszukiwania dla: SIGNAL DENOISING
-
The Use of Wavelet Analysis to Denoising of Electrocardiography Signal
PublikacjaThe electrocardiography examination, due to its accessibility and simplicity, has an important role in diagnostics of the heart ailments. It enables quick detection of various heart defects, undetectable by other kinds of diagnostic tools, so it is very popular. Nevertheless, the measured signal is exposed to a different disturbances. Among them, the electromagnetic interferences, drift of reference electrode and high frequency...
-
Wavelet-based denoising method for real phonocardiography signal recorded by mobile devices in noisy environment
PublikacjaThe main obstacle in development of intelligent autodiagnosis medical systems based on the analysis of phonocardiography (PCG) signals is noise. The noise can be caused by digestive and respiration sounds, movements or even signals from the surrounding environment and it is characterized by wide frequency and intensity spectrum. This spectrum overlaps the heart tones spectrum, which makes the problem of PCG signal filtrating complex....
-
Arm EMG Wavelet-Based Denoising System
PublikacjaThese paper presents research results of muscle EMG signal denoising. In the same time two muscles were examined - an adductor muscle (biceps brachii) and an abductor muscle (tricpeps brachii). The EMG signal was filtered using the wavelet transform technique, having selected the crucial parameters as: wavelet basis function (Daubechies 4), 10 th decomposition level, threshold selection algorithm (Heurestic) and a sln rescaling...
-
Review and comparison of smoothing algorithms for one-dimensional data noise reduction
PublikacjaThe paper considers the choice of parameters of smoothing algorithms for data denoising. The impact of the window size on smoothing accuracy was analyzed. The parameters of denoising filters were selected with respect to the meansquare error between the computed linear regression and the noisy signal. Finally, we have compared mean, median, SavitzkyGolay, Kalman and Gaussian filter algorithms for the data from the digital sensor....
-
Adaptacyjny algorytm filtracji sygnału fonokardiograficznego wykorzystujący sztuczną sieć neuronową
PublikacjaPodstawowym problemem podczas projektowania systemu autodiagnostyki chorób serca, bazującego na analizie sygnału fonokardiograficznego (PCG), jest konieczność zapewnienia, niezależnie od warunków zewnętrznych, sygnału o wysokiej jakości. W artykule, bazując na zdolności Sztucznej Sieci Neuronowej (SSN) do predykcji sygnałów periodycznych oraz quasi-periodycznych, został opracowany adaptacyjny algorytm filtracji dźwięków serca....
-
Noise sources in Raman spectroscopy of biological objects
PublikacjaWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
BP-EVD: Forward Block-Output Propagation for Efficient Video Denoising
PublikacjaDenoising videos in real-time is critical in many applications, including robotics and medicine, where varying light conditions, miniaturized sensors, and optics can substantially compromise image quality. This work proposes the first video denoising method based on a deep neural network that achieves state-of-the-art performance on dynamic scenes while running in real-time on VGA video resolution with no frame latency. The backbone...
-
On cooperative image denoising
PublikacjaIn this paper we suggest how several competing image denoising algorithms, differing in design parameters, or even in design principles, can be combined together to yield a better and more reliable denoising algorithm. The proposed fusion mechanism allows one to combine practically all kinds of noise reduction tools. It also allows one to account for the distribution of measurement noise, and in particular - to cope with heavy-tailed...
-
Assessment of particular abdominal aorta section extraction from contrast-enhanced computed tomography angiography
PublikacjaThe aim of this work is to improve the accuracy of extraction of a particular abdominal aorta section and to reduce the distortion in three-dimensional Computed Tomography Angiography (CTA) images. Imaging modality and quality plays crucial role in the medical diagnostic process, thus ensuring high quality of images is essential at every stage of acquisition and processing.Noise is defined as a disturbance of the image quality...
-
Analysis of Denoising Autoencoder Properties Through Misspelling Correction Task
PublikacjaThe paper analyzes some properties of denoising autoencoders using the problem of misspellings correction as an exemplary task. We evaluate the capacity of the network in its classical feed-forward form. We also propose a modification to the output layer of the net, which we called multi-softmax. Experiments show that the model trained with this output layer outperforms traditional network both in learning time and accuracy. We...