Filtry
wszystkich: 9948
-
Katalog
- Publikacje 9009 wyników po odfiltrowaniu
- Czasopisma 50 wyników po odfiltrowaniu
- Konferencje 18 wyników po odfiltrowaniu
- Osoby 95 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 54 wyników po odfiltrowaniu
- Wydarzenia 7 wyników po odfiltrowaniu
- Dane Badawcze 712 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: Ti-based alloys
-
Hydroxyapatite coatings on porous ti and ti alloys
PublikacjaDeposition of hydroxyapatite coating on porous Ti and Ti alloys with electrochemical and biomimetic deposition approach is presented. The enhancement of phosphates deposition by well oriented and uniform titanium oxide nanotube array on the surface of titanium substrate is discussed.
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublikacjaTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...
-
Surface modifications of ti and its alloys
PublikacjaThis article reviews the various surface modification techniques pertaining to titanium and titanium alloys including physical treatment, mechanical treatment, and chemical and electrochemical treatment. The proper surface modification expands the use of titanium and its alloys in the biomedical field for long-term implants retaining the excellent properties of substrate material and improving the specific surface properties required...
-
Optimization of Self-Organized TiO2 Nanotube Geometry on Ti and Ti Alloys Using Fuzzy Logic Reasoning
PublikacjaThe geometry of self-organized TiO2 nanotubes, obtained by electrochemicalanodization, has been determined by using fuzzy reasoning approach. The efficiency of TiO2nanotubular layer in biomedical applications depends on geometry and available surface area ofnanotubes, which can be determined by their diameter and length. The structure of nanotubesdepends on processing parameters of electrochemical anodization, like applied potential,anodization...
-
Environmental degradation of Ti alloys in artificial saliva and a role of fluorides
PublikacjaThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Optimal Features of Porosity of Ti Alloys Considering their Bioactivity and Mechanical Properties
PublikacjaW artykule przedstawiono wpływ porowatości i rozmiaru porów tytanu i jego stopów, użytych, jako materiały ortopedyczne, na bioaktywność i własności mechaniczne struktur porowatych. Optymalne cechy porowatych rusztowań tytanowych umożliwiają rekonstrukcję i regenerację tkanki kostnej w zastosowaniach przenoszących obciażenie.
-
Evaluation of Wear Resistance of Ti alloys used for elements friction of knee endoprosthesis
PublikacjaThe paper presents research results of resistance to abrasive wear of titanium alloys: Ti6Al4V (commonly used) and Til3Nb13Zr (alloy of new generation) in association with polyethylene (UHMW-PE) predisposed for elements on pair of the knee endoprosthesis. The results were analysed from the point of possibility of an use of new generation titanium alloys as components of such implants. The tests of resistance to abrasive wear of...
-
Evaluation of the Microstructure and Magnetic Properties of Fe73Me5Y3B19 (Where Me = Ti or Nb) Amorphous Alloys
Publikacja -
Electrostatic self-assembly approach in the deposition of bio-functional chitosan-based layers enriched with caffeic acid on Ti-6Al-7Nb alloys by alternate immersion
Publikacja -
Improvement of machinability of Ti and its alloys using cooling-lubrication techniques: a review and future prospect
Publikacja -
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublikacjaNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...
-
Optimization of biocorrosion resistance and mechanical properties of PM Ti–XAl–2Fe–3Cu alloys by response surface methodology
PublikacjaIn the current study, the biocorrosion resistance and mechanical properties of the Ti–XAl–2Fe–3Cu (wt%) (X = 6, 4, 2 wt%) alloy produced by powder compact extrusion of blended elemental powders were optimized by using the response surface methodology in order to gain the best combination of processing parameters. To run the optimization process, central composite design with three equal levels of oxygen, hydrogen and aluminum was...
-
Seismic Response Analysis of Knee-Braced Steel Frames Using Ni-Ti Shape Memory Alloys (SMAs)
PublikacjaShape Memory Alloys (SMAs) are known as active materials that can be widely used for structural purposes due to their flag-shape behavior under loading and reloading. Their unique characteristics provided a potential solution for civil engi-neers especially to model buildings with the capability of dissipating seismic en-ergy. In this study, the main purpose is to explore the seismic behavior of Knee-Braced Frames (KBFs) and...
-
XPS measurement of the Fe-Ti based materials
Dane BadawczeThe mono‐ and bimetal‐modified (Pd, Cu) titanium(IV) oxide and iron oxide (III) photocatalysts were prepared by chemical reduction method and characterized using XPS method. The composition of elements incorporated in the surface layer of mono- and bimetallic photocatalysts was determined by XPS analysis, as well as the valence state of elements. Measurements...
-
Structural and Material Determinants Influencing the Behavior of Porous Ti and Its Alloys Made by Additive Manufacturing Techniques for Biomedical Applications
PublikacjaOne of the biggest challenges in tissue engineering is the manufacturing of porous structures that are customized in size and shape and that mimic natural bone structure. Additive manufacturing is known as a sufficient method to produce 3D porous structures used as bone substitutes in large segmental bone defects. The literature indicates that the mechanical and biological properties of scaffolds highly depend on geometrical features...
-
Effects of Sr/Ti stoichiometry in SrTiO3-based SOFC anodes
PublikacjaScharakteryzowano wpływ stechiometrii Sr/Ti na właściwości strukturalne, elektryczne i mechaniczne anod na bazie tytanianu strontu. Wyjaśniono genezę niektórych zjawisk w oparciu o chemię defektów związków niestechiometrycznych na bazie istniejących pozycji literaturowych.
-
The Influence of Casein Coatings on the Corrosion Behavior of Mg-Based Alloys
Publikacja -
Low current transformer utilizing Co-based amorphous alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
The influence of microstructure on the corrosion resistance for some titanium-based alloys
Dane BadawczeThis dataset contains scanning electron microscopy (SEM) micrographs revealing the microstructure of some Ti-based alloys, namely: Ti-6Al-4V (file name: TiV), Ti-6Al-7Nb (file name: TiNb) and TC21 (file name: TiAlSnZrMoCrNbSi) alloys and their localized corrosion as a result of passive layer breakdown in a corrosive environment, ie. 0.9% NaCl solution...