Filtry
wszystkich: 34
Wyniki wyszukiwania dla: breath analyses
-
Volatile Compound Emissions from Stereolithography Three-Dimensional Printed Cured Resin Models for Biomedical Applications
PublikacjaStereolithography three-dimensional printing is used increasingly in biomedical applications to create components for use in healthcare and therapy. The exposure of patients to volatile organic compounds (VOCs) emitted from cured resins represents an element of concern in such applications. Here, we investigate the biocompatibility in relation to inhalation exposure of volatile emissions of three different cured commercial resins...
-
Analysis of exhaled breath for dengue disease detection by low-cost electronic nose system
PublikacjaThis paper presents a procedure and a set-up of an electronic nose system analyzing exhaled breath to detect the patients suffering from dengue – a mosquito-borne tropical disease. Low-power resistive gas sensors (MiCS-6814, TGS8100) were used to detect volatile organic compounds (VOCs) in the exhaled breath. The end-tidal phase of patients exhaled breath was collected with a BioVOCTM breath sampler. Two strategies were assessed...
-
The compositional space of exhaled breath condensate and its link to the human breath volatilome
PublikacjaBreath analysis is commonly understood to target gaseous or volatile organic compounds (VOCs) for the characterization of different pathologies. Targeted analysis is most effective if a working hypothesis can be based on a plethora of data. The recently published volatilome builds an optimal basis for organizing powerful target sets. However, the origin and pathways of biosynthesis of many VOCs are not known, which complicates...
-
Exhaled breath analysis by resistive gas sensors
PublikacjaBreath analysis has attracted human beings for centuries. It was one of the simplest methods to detect various diseases by using human smell sense only. Advances in technology enable to use more reliable and standardized methods, based on different gas sensing systems. Breath analysis requires the detection of volatile organic compounds (VOCs) of the concentrations below individual ppm (parts per million). Therefore, advanced detection...
-
Exhaled breath gas sensing using pristine and functionalized WO3 nanowire sensors enhanced by UV-light irradiation
PublikacjaThe development of advanced metal-oxide-semiconductor sensing technologies for the detection of Volatile Organic Compounds (VOCs) present in exhaled breath is of great importance for non-invasive, cheap and fast medical diagnostics. Our experimental studies investigate the effects of operating temperature selection and UV-light irradiation on improving the response of WO3 nanowire sensors towards exhaled breath exposure. Herein,...
-
A breath of fresh air - social cognitive career theory in studying entrepreneurial intentions
PublikacjaA pinch of robustness and a pinch of freshness create an interesting story. That is why this study focuses on entrepreneurial intentions from an alternative theoretical perspective in an underexplored context. In this paper, it is argued that social cognitive career theory is relevant to the study of individual entrepreneurial cognition and behaviour, and it offers a solid framework in entrepreneurship research. This paper expands...
-
Fluctuation-Enhanced Sensing with Organically Functionalized Gold Nanoparticle Gas Sensors Targeting Biomedical Applications
PublikacjaDetection of volatile organic compounds is a useful approach to non-invasive diagnosis of diseases through breath analysis. Our experimental study presents a newly developed prototype gas sensor, based on organically-functionalized gold nanoparticles, and results on formaldehyde detection using fluctuation-enhanced gas sensing. Formaldehyde was easily detected via intense fluctuations of the gas sensor’s resistance, while the cross-influence...
-
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
PublikacjaThis paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublikacjaHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Modeling of Cardiac Component of Subarachnoid Space Changes in Apnoea Resulting as a Function of Blood Pressure and Blood Flow Parameters - Two Mechanizm of Regulation
PublikacjaExperiments were performed in a group of 19 healthy, non-smoking volunteers. The experiment consisted of three apnoeas, sequentially: 30 s apnoea, 60 s apnoea and maximal, that could be done, apnoea. The breath-hold was separated for 5 minutes rest. The following parameters were measured and obtained for further analysis: blood parameters, artery diameter of the internal carotid artery, end-tidal CO2 in expired air, the cardiac...
-
Automatic Breath Analysis System Using Convolutional Neural Networks
PublikacjaDiseases related to the human respiratory system have always been a burden for the entire society. The situation has become particularly difficult now after the outbreak of the COVID-19 pandemic. Even now, however, it is not uncommon for people to consult their doctor too late, after the disease has developed. To protect patients from severe disease, it is recommended that any symptoms disturbing the respiratory system be detected...
-
Automatic Breath Analysis System Using Convolutional Neural Networks
PublikacjaDiseases related to the human respiratory system have always been a burden for the entire society. The situation has become particularly difficult now after the outbreak of the COVID-19 pandemic. Even now, however, it is common for people to consult their doctor too late, after the disease has developed. To protect patients from severe disease, it is recommended that any symptoms disturbing the respiratory system be detected as...
-
System of breath collection and analysis for diseases detection
PublikacjaCollection and study of composition of the exhaled air is now intensively investigated to develop non-invasive medical diagnostics based on presence of metabolic compounds in the exhaled air. The process of collecting and processing of the exhaled air must fulfill relevant conditions to achieve satisfactory results. The paper presents the system of collecting samples of exhaled breath and the proposed methods of its analysis, using...
-
Modelling of subarachnoid space width changes in apnoea resulting as a function of blood flow parameters
PublikacjaDuring apnoea, the pial artery is subjected to two opposite physiological processes: vasoconstriction due to elevated blood pressure and vasorelaxation driven by rising pH in the brain parenchyma. We hypothesized that the pial artery response to apnoea may vary, depending on which process dominate. Apnoea experiments were performed in a group of 19 healthy, non-smoking volunteers (9 men and 10 women). The following parameters...
-
Sensitive determination of isoprostanes in exhaled breath condensate samples with use of liquid chromatography-tandem mass spectrometry
PublikacjaOxidative stress is the hallmark of various inflammatory lung diseases. Increased concentrations of reactive oxygen species in the lungs are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. The aim of this work was to develop a method for the fast measurement of F2 isoprostanes in exhaled breath condensate (EBC) samples using equipment which is nowadays available and...
-
A body position influence on ECG derived respiration
PublikacjaAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
Instrumental techniques used in the analysis of exhaled air
PublikacjaExhaled air composition changes depending on the health status of the patient, making it possible to use breath analysis for diagnosis and monitoring purposes. Despite the fact that it is not yet used in every day medical practice, it potential application could facilitate the diagnostics of various diseases such as metabolic disorders, respiratory tract and gastrointestinal diseases. Described in this paper are different application...
-
Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
PublikacjaPurpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on...
-
Effect of Maximal Breath Hold Apnea on Pial Artery Pulsation and Subarachnoid Width in Human
PublikacjaLittle is known about intracranial pressure (ICP)-cerebral hemodynamic interplay during maximal breath-hold apnea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Changes in sas-TQ correlate with ICP to a considerable extent, whereas cc-TQ reflects the functional...
-
Emotion Monitor - Concept, Construction and Lessons Learned
PublikacjaThis paper concerns the design and physical construction of an emotion monitor stand for tracking human emotions in Human-Computer Interaction using multi-modal approach. The concept of the stand using cameras, behavioral analysis tools and a set of physiological sensors such as galvanic skin response, blood-volume pulse, temperature, breath and electromyography is presented and followed...