Filtry
wszystkich: 20
Wyniki wyszukiwania dla: knee joint
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
Modeling knee joint endoprosthesis mode of deformation
Publikacja -
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublikacjaObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
Assessment of the Relationship between the Shape of the Lateral Meniscus and the Risk of Extrusion Based on MRI Examination of the Knee Joint
PublikacjaBackground Meniscus extrusion is a serious and relatively frequent clinical problem. For this reason the role of different risk factors for this pathology is still the subject of debate. The goal of this study was to verify the results of previous theoretical work, based on the mathematical models, regarding a relationship between the cross-section shape of the meniscus and the risk of its extrusion. Materials and Methods Knee...
-
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublikacjaWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublikacjaPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics
PublikacjaObjective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis...
-
Proximal fibular osteotomy as a treatment for degenerative meniscal extrusion
PublikacjaMeniscal extrusion treatment is a key focus area for research and clinical study of degenerative knee pathology. The contact forces between the meniscus and the bones cause external displacements of the meniscus that are resisted by the circumferential fibres. The main risk factors for the excessive deformation of the meniscus are meniscal root tears, disruption of the circumferential fibres, knee malalignment and high body mass...
-
3D knee model G with reduced thickness of articular cartilage - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model G articular cartilage thickness was reduced in specific areas to simulate degenerative changes in the medial knee osteoarthritis. The file was...
-
3D knee model M with decreased material parameters of the cartilage and menisci - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model M the material parameters of cartilage and menisci were reduced to simulate degenerative changes in the medial knee osteoarthritis. The file...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublikacjaThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Wpływ wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego
PublikacjaW rozprawie podjęto próbę weryfikacji wpływu zabiegu chirurgicznego wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego. Po wykonanym przeglądzie literatury, postawiono trzy hipotezy, które poddano weryfikacji na drodze badań numerycznych. Otrzymane wyniki zwalidowano poprzez badania nacisków powierzchniowych występujących w stawach kolanowych świni domowej, prowadzonych na maszynie do jednoosiowego ściskania. Praca...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublikacjaThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Approach for Determination of Functioning of Lower Limb Muscles
PublikacjaThe purpose of the study is elaboration of approach for determination of functioning of chosen muscles that are essential for gait performance (Tibialis Anterior, Rectus Femoris, Gastrocnemius Medialis, Biceps Femoris). The scope of the study involves the analysis of the symmetric planar motion performing in the sagittal plane of the body by applying planar multibody model and electromyography signals (EMG) registered over normal...
-
pH-dependent composite coatings for controlled drug delivery system - Review
PublikacjaNowadays in case of long-term implants, the most common postoperative complications are bacterial infections, which in consequence may provoke loos- ening of the implants in the primary phase of stabilization. Bacterial infections are currently the most frequent cause of revision surgery of the implants such as hip joint endoprosthesis, knee joint endoprosthesis and dental implants. In order to provide the local and long-term antibacterial...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublikacjaThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Ocena odporności na zużycie ścierne stopów Ti na elementy pary trącej endoprotez stawu kolanowego
PublikacjaNajczęściej stosowanym biomateriałem tytanowym na elementy endoprotez stawu kolanowego jest stop Ti6Al4V. Z uwagi na zawartość wanadu, zaliczanego do pierwiastków o dużej toksyczności podejmowane są działania w kierunku zastąpienia wskazanego stopu - stopami bezwanadowymi. Jednym z najbardziej obiecujących jest stop Ti13Nb13Zr zawierający w swoim składzie jedynie pierwiastki witalne, niewywołujące stanów zapalnych i odczynów...
-
Evaluation of Wear Resistance of Ti alloys used for elements friction of knee endoprosthesis
PublikacjaThe paper presents research results of resistance to abrasive wear of titanium alloys: Ti6Al4V (commonly used) and Til3Nb13Zr (alloy of new generation) in association with polyethylene (UHMW-PE) predisposed for elements on pair of the knee endoprosthesis. The results were analysed from the point of possibility of an use of new generation titanium alloys as components of such implants. The tests of resistance to abrasive wear of...