Filtry
wszystkich: 4571
-
Katalog
- Publikacje 3559 wyników po odfiltrowaniu
- Czasopisma 88 wyników po odfiltrowaniu
- Konferencje 5 wyników po odfiltrowaniu
- Osoby 108 wyników po odfiltrowaniu
- Projekty 6 wyników po odfiltrowaniu
- Kursy Online 73 wyników po odfiltrowaniu
- Wydarzenia 26 wyników po odfiltrowaniu
- Oferty 1 wyników po odfiltrowaniu
- Dane Badawcze 705 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: shunt%20active%20power%20filter
-
Predictive control system of the shunt active power filter
Publikacja -
New control system of the shunt active power filter
Publikacja -
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublikacjaThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublikacjaThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publikacja -
Compensation of Dead Time Effects for Shunt Active Power Filters
PublikacjaThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublikacjaThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
A filter bank solution for active power filter control algorithms
PublikacjaThb paper describes the proposed active power fiIter (APF) with a new control circuit based on an algorithm using ufilter bank and a harmonic predictor. The conirol circuit was realized using the digiiaI signor processor ADSP-21065L and FPGA circuiL In the proposed circuit transient performunee of APF is improved The active power fdter circuil has been built and teste6 and some illustrative, experimental results are uIso presented...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublikacjaMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
A Special Multi-Pulse Converter with Small Active Power Filter
Publikacja -
Experimental tests results of the diode rectifier with series active power filter
Publikacja -
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publikacja -
Static Shunt PE Voltage-Quality Controllers
PublikacjaThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
A diode rectifier with a Special Coupled Reactor and additional Active Power Filter in the Marine Local Power Network Supply Conditions
Publikacja -
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublikacjaThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Lipogranulomas and pigment granulomas in livers of dogs with portosystemic shunt
Publikacja -
REACTIVE & FUNCTIONAL POLYMERS
Czasopisma -
The Methodology of identifying the place to install shunt compensators in the transmission network
PublikacjaThis methodology of selection and localization of static com- paper presents pensators in wide network. Proposed method is based on analysis of voltage area power profiles in the nodes of the power grid, and designating locations, In Which Voltages ex- cessively tend to change in time. Practical way of modeling the SVC device in PLANS program you Presented, as well as some example results of research.
-
Histopathological picture of pancreatic islets in dogs with congenital portosystemic shunt
Publikacja