Filtry
wszystkich: 627
wybranych: 81
Wyniki wyszukiwania dla: CLINKER FAÇADES
-
Determining the optimal filling of the surface with a linker with Universal Force Field and Reax Force Field
Dane BadawczeThe DataSet contains the atomic slabs of diamond surfaces with ATP molecules in water. The calculated data includes different sized surfaces from 90 Angstrom^2 to 691 Angstrom^2. Structures were relaxed using the Reax Force Field method with the Limited Memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Structures were calculated with a convergence...
-
The instantaneous flicker sensation level measured in the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application...
-
The short-term flicker severity level measured in the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents a short-term flicker severity level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of...
-
A cumulative probability function of instantaneous flicker sensation values measured in the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents a cumulative probability function CPF of the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage...
-
Cytotoxicity of QDgreen-holo-Tf-C-2028 and QDred-holo-Tf-C-2028 aginst H460 cancer cells_method of synthesis 2
Dane BadawczeThis study presents absorbance of formazan product (converted from MTT) which corresponds the cytotoxicity of QDgreen-holo-Tf-C-2028 and QDred-holo-Tf-C-2028 aginst H460 cancer cells (method of synthesis 2). Holo-Tf (transferrin) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of QDgreen-holo-Tf-C-2028 and QDred-holo-Tf-C-2028 aginst H460 cancer cells_method of synthesis 3
Dane BadawczeThis study presents absorbance of formazan product (converted from MTT) which corresponds the cytotoxicity of QDgreen-holo-Tf-C-2028 and QDred-holo-Tf-C-2028 aginst H460 cancer cells (method of synthesis 3). Holo-Tf (transferrin) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen-FA, QDred-FA, QDgreen-FA-C-2028 and QDred-FA-C-2028 aginst H460 cancer cells
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen-FA, QDred-FA, QDgreen-FA-C-2028 and QDred-FA-C-2028 aginst H460 cancer cells. FA (folic acid) was used as a linker between quantum dots (QDs) and compound (C-2028) at different concentration (50-200 µM).
-
Cytotoxicity of QDgreen-holo-Tf, QDred-holo-Tf, QDgreen-holo-Tf-C-2028 and QDred-holo-Tf-C-2028 aginst H460 cancer cells_method of synthesis 1
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of QDgreen-holo-Tf, QDred-holo-Tf, QDgreen-holo-Tf-C-2028 and QDred-holo-Tf-C-2028 aginst H460 cancer cells (method of synthesis 1). Holo-Tf (transferrin) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-FA, QDred-FA, QDgreen-FA-C-2028 and QDred-FA-C-2028 aginst LNCaP cancer cells
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-FA, QDred-FA, QDgreen-FA-C-2028 and QDred-FA-C-2028 aginst LNCaP cancer cells. FA (folic acid) was used as a linker between quantum dots (QDs) and compound (C-2028) at different concentration (50-200 µM).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-FA, QDred-FA, QDgreen-FA-C-2028 and QDred-FA-C-2028 aginst Du-145 cancer cells
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-FA, QDred-FA, QDgreen-FA-C-2028 and QDred-FA-C-2028 aginst H460 cancer cells. FA (folic acid) was used as a linker between quantum dots (QDs) and compound (C-2028) at different concentration (50-200 µM).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst LNCaP cancer cells
Dane BadawczeTis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst LNCaP cancer cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst Du-145 cancer cells
Dane BadawczeTis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst LNCaP cancer cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst H460 cancer cells
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst H460 cancer cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst MRC-5 normal cells
Dane BadawczeTis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst MRC-5 normal cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Nuclear Magnetic Resonance data for the synthesis of esterase cleavable antifungal conjugates containing fatty acids as molecular carriers
Dane BadawczeNMR data for novel organic compounds - conjugates composed of C2-18 fatty acid (FA) residues as a molecular carrier and 5-fluorocytosine (5-FC) as an active agent, released upon the action of intracellular esterases on the ester bond between FA and “trimethyl lock” intramolecular linker.
-
Raman spectra of CPMH and CPMD
Dane BadawczeThese data contains Raman spectra of CPMH and CPMD. Raman scattering was measured with a RenishawmicroRaman spectrometer (785 nm). Sample abbreviations (CPMH, CPMD) are in agreement with the markings used in the linked publication.
-
CV (cyclic voltammetry) curves of the CPMD sample at different scan rates
Dane BadawczeThese data contain CV curves of CPMD obtained at a scan rate from 1 mV s−1 to 20 mV s−1. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.
-
Evaluation of the electrochemical performance of CPMD in ZICs with 3M ZnSO4 electrolyte
Dane BadawczeThese data contain the results of the electrochemical performance measurements of CPMD in ZICs with 3M ZnSO4 electrolyte, incl. CGD (galvanostatic charge-discharge ) curve and cycling stability of CPMD. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.
-
The results of the nitrogen adsorption/desorption measurements of CPMD and CPMH
Dane BadawczeThe results of the nitrogen adsorption/desorption measurements of CPMD and CPMH. The adsorption/desorption isothermswere carried out at 77 K using a Quantachrome Autosorb-1C-MS instrument. Sample abbreviations (CPMD, CPMH) are in agreement with the markings used in the linked publication.
-
Performance of Haemophilus influenzae impedimetric biosensors based on screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy studies of SPCE electrodes containing boron-doped diamond BDD foils and functionalized towards detection of Protein D and Haemophilus influenzae.
-
XRD (X-ray Diffraction) patterns of PMH, PMD and simulated MIL-53(Al)
Dane BadawczeThese data contain XRD (X-ray Diffraction) patterns of PMH, PMD and simulated MIL-53(Al). The results were recorded by a Philipsdiffractometer using Cu Ka radiation. Sample abbreviations (PMH, PMD, MIL-53(Al)) are in agreement with the markings used in the linked publication.
-
Elgold partial: News
Dane BadawczeThe dataset contains 37 English texts scrapped from news websites. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking...
-
Thermal properties. DSC analysis of poly(xylitol sebacate-co-butylene sebacate) PXBS.
Dane BadawczeIn this work, a bio-based copolyester with good mechanical properties was synthesized andcharacterized in terms of structure, main properties and biodegradability Determining the chemicalstructure of such materials is important to understand their behavior and properties. Performingan extraction of insoluble cross-linked polymer using di erent solvents...
-
Ex-situ XRD (X-ray Diffraction) results for electrodes under different charge/discharge states
Dane BadawczeEx-situ XRD was employed to analyze the energy storage mechanism of CPMD in ZICs system. The ZICs were firstly charged to 1.8 V from the open circuit voltage (at around 1.3 V), then discharge to 1.0 V and 0.2 V, and finally recharged to 1.0 V and 1.8 V. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.
-
SEM (scanning electron microscopy) and TEM (transmission electron microscopy) images of PMD and PMH
Dane BadawczeThese data contains SEM (scanning electron microscopy) and TEM (transmission electron microscopy) images of PMD and PMH. TEM was performed on a FEI Tecnai F30 transmission electron microscope operating at an acceleration voltage of 200 kV. SEM was done with a SEM, XL30ESEM-FEG with an acceleration voltage of 20 KV. Sample abbreviations (PMH, PMD) are...
-
XPS (X-ray photoelectron spectroscopy) survey spectra of CPMD and CPMH
Dane BadawczeXPS (X-ray photoelectron spectroscopy) survey spectra of CPMD and CPMH. XPS spectra were obtained using Al Kɑ (hv=1486.6 eV) radiation with a Prevac system equipped with a Scienta SES 2002 electron energy analyzer operating at constant transmission energy (Ep=50 eV). Sample abbreviations (CPMD, CPMH) are in agreement with the markings used in the linked...
-
Elgold partial: Scientific papers' abstracts
Dane BadawczeThe dataset contains 87 Scientific papers' abstracts in English randomly chosen from the folowing scientific disciplines: Biomedicine, Life Sciences, Mathematics, Medicine, Science, Humanities, Social Science.
-
Elgold partial: Amazon product reviews
Dane BadawczeThe dataset contains 34 Amazon product reviews in English. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking algorithms.
-
Elgold partial: Automotive blogs
Dane BadawczeThe dataset contains 34 English texts scrapped from automotive blogs. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and...
-
Elgold partial: Movie reviews
Dane BadawczeThe dataset contains 37 English texts with movie reviews. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking algorithms.
-
Elgold partial: Job offers
Dane BadawczeThe dataset contains 34 English texts scrapped from the web portals offering job offers. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity...
-
Elgold partial: History blogs
Dane BadawczeThe dataset contains 13 texts from English history blogs. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking algorithms.
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....