Wyniki wyszukiwania dla: DIOLE
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Modified polycarbonate urethane: synthesis, properties and biological investigation in vitro
PublikacjaNowy poliweglano uretan (PCU-I) otrzymano z alifatycznych monomerów: poliwęglanu heksanodiolu, 4,4'diizocyjanianu dicykloheksanometanu, mieszaniny małocząsteczkowych dioli i oleju rycynowego (zawierającego głównie trigliceryd kwasu 12-hydroksyoleinowego). PCU-II otrzymano analogicznie ale bez udziału oleju rycynowego. Obydwa PCU charakteryzowały się dobrą wytrzymałością na rozciąganie. PCU-I miał niższą temperaturę zeszklenia a...
-
A magnetic imprinted polymer nano-adsorbent with embedded quantum dots and mesoporous carbon for the microextraction of triazine herbicides
PublikacjaA magnetic molecularly imprinted polymer (MMIP) adsorbent incorporating amino-functionalized magnetite nanoparticles, nitrogen-doped graphene quantum dots and mesoporous carbon (MIP@MPC@NGQDs@ Fe3O4–NH2) was fabricated to extract triazine herbicides from fruit juice. The embedded magnetite nanoparticles simplified the isolation of the adsorbent from the sample solution. The N-GQDs and MPC enhanced adsorption by affinity binding...
-
Signature of Hydrodynamic Pressure Field
PublikacjaW artykule przedstawiono wyniki obliczeń pola hydrodynamicznego ciśnienia wokół okrętu specjalnego jako funkcji przestrzennej, obliczonej metodą brzegową. Obliczone pola ćiśnienia hydrodynamicznego jest porównywane z pomierzonym polem okrętu na morzu, przy czym opis kształtu kadłuba okrętu jest przybliżony. Przedstawione wyniki obliczeń uzyskano stosując warstwę pojedynczą , którą stanowią źródła o rozkładzie ciągłym. Skonstruowany...