Publikacje
Filtry
wszystkich: 750
Katalog Publikacji
-
Computer support of analysis optical spectra measurements
PublikacjaVerification of measurement errors has a big impact on assessment of accuracy of conducted measurements and obtained results. In many cases computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with Fabry-Perot interferometer working in the transmission mode. In measurement setup, a 1310 nm superluminescent...
-
Możliwości i ryzyka związane z automatyzacją weryfikacji pracy studentów na przykładzie przedmiotu Metrologia
PublikacjaPrzedmiot Metrologia jest wykładany na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej na trzecim semestrze studiów na trzech kierunkach: Elektronika i Telekomunikacja, Inżynieria Biomedyczna oraz Automatyka, Cybernetyka i Robotyka. W trakcie zajęć laboratoryjnych studenci wykonują sześć ćwiczeń, z których dwa są całkowicie oceniane przez program weryfikujący...
-
Porównanie efektów nauczania przed i w czasie nauki zdalnej spowodowanej pandemią SARS-CoV-2 na przykładzie przedmiotu Metrologia
PublikacjaPrzedmiot Metrologia jest wykładany na semestrze drugim na trzech kierunkach na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej. W ramach wykładu studenci poznają problematykę dokonywania pomiarów. W kolejnym semestrze, przekładają zdobytą teoretycznie wiedzę na praktykę, wykonując pomiary w laboratorium. Z uwagi na wybuch pandemii SARS-CoV-2 w 2020 roku oraz...
-
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublikacjaMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Corrigendum to “T1 relaxation time callibration in magnetic resonance imaging using nanodiamond phantoms” [Phys Med 94 (2022) S119–S120/EPV029]
PublikacjaThe authors want to update the incorrect funding information. The correct funding note is: “The authors acknowledge the financial support from Gdańsk University of Technology by the 4/2020/IDUB/III.4.1/Tc grant under the Technetium Talent Management Grants ‘Excellence Initiative – Research University’. The financial support from Gdańsk University of Technology by the 1/2021/IDUB/II.2/Np grant under NEPTUNIUM Enhancing Baltic Region...
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublikacjaTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Ab-initio study of electrical and optical properties of allylamine
PublikacjaThe Density functional theory is one of most promising methodology in fast and accurate calculations of electrical and optical properties from the atomic basis. In this paper, we calculate electrical and optical properties of allylamine (2-propen 1- amine) in terms of accuracy and speed of calculations obtained by selection of DFT-1/2 method with ultrasoft Vanderbilt pseudopotentials. Comparison of density of states between...
-
Analiza efektywności systemów oświetlania roślin na przykładzie uprawy bazylii
Publikacja -
Tuning of the finesse coefficient of optoelectronic devices
PublikacjaOptoelectronic devices attracted considerable attention in many branches of science and technology, which can be attributed to their unique properties. Many of them use optical cavities which parameters can be adopted to specific requirements. This thesis investigates the introduction of diamond structures (nitrogen-doped diamond film, boron-doped diamond film, undoped diamond sheet) to optical cavities to tune their finesse coefficient....
-
Diamond Structures for Tuning of the Finesse Coefficient of Photonic Devices
PublikacjaFinesse coefficient is one of the most important parameters describing the properties of a resonant cavity. In this research, a mathematical investigation of the application of diamond structures in a fiber-optic Fabry–Perot measurement head to assess their impact on the finesse coefficient is proposed. We present modeled transmission functions of cavities utilizing a nitrogen-doped diamond, a boron-doped diamond, nanocrystalline...
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublikacjaA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublikacjaThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublikacjaThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublikacjaIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublikacjaThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
REJESTRACJA SERII ZDJĘĆ, Z WYMUSZENIEM ZMIENNYCH WARUNKÓW OŚWIETLENIOWYCH, JAKO TECHNIKI WSPOMAGAJĄCEJ PRZY AUTOMATYCZNYM ROZPOZNAWANIU TEKSTU
PublikacjaW artykule przedstawiono autorskie rozwiązania problemu wykonywania zdjęć niewyraźnych tekstów na opakowaniach i niewielkich produktach. W sytuacji gdy napis posiada niską rozdzielczość (drukarka atramentowa), albo jest wykonany poprzez technikę tłoczenia, wykonanie zwykłego, pojedynczego zdjęcia daje przeważnie niezadowalające wyniki. Dzięki przedstawionym tu rozwiązaniom, znacząco polepszamy materiał wejściowy (fotografie), który...
-
Towards spectral sensitivity curve for two-photon vision mechanism
PublikacjaAbstract Purpose: The perceived brightness of different visible light sources can be compared with photometric units based on the standardized luminosity curves (300-780nm range). As reported previously (PNAS 111(50), pp. E5445-E5454 (2014)), near-infrared (NIR) radiation can cause isomerization of visual pigments by one- or two-photon absorption. The perceived color of the stimulus is red in the case of one-photon vision (1PV)...
-
PROJEKT LISTWY ZASILAJĄCEJ W OPARCIU O KONCEPCJĘ INTERNETU RZECZY
PublikacjaW referacie przedstawiono podstawowe uwarunkowania, jakimi należy kierować się przy opracowywaniu urządzeń należących do klasy obiektów określanych mianem „Internetu Rzeczy” na przykładzie zrealizowanego prototypu listwy zasilającej. Przedstawione w pracy urządzenie przeznaczone jest do sterowanie różnorodnymi odbiornikami energii elektrycznej niemogącymi być bezpośrednio sterowanymi z sieci Ethernet. W pracy przedstawiono przyjęte...
-
Łączenie danych pomiarowych z dodatkową wiedzą metrologiczną w celu oceny niepewności pomiaru
PublikacjaPrzedstawiono modus operandi w ocenie niepewności pomiaru dla krótkich serii pomiarowych. Metoda wykorzystuje dodatkową wiedzę metrologiczną do zwiększenia liczby stopni swobody rozkładu t-Studenta, uzyskiwanego w wyniku bayesowskiej analizy wyników pomiarów. W rezultacie możliwe jest oszacowanie niepewności standardowych dla najkrótszych serii pomiarowych, o długości n=2 i n=3.
-
UKŁAD I PROGRAM DO WYZNACZANIA PARAMETRÓW SCHEMATU ZASTĘPCZEGO SUPERKONDENSATORA
PublikacjaW pracy przedstawiono prototyp urządzenia do wyznaczania parametrów schematu zastępczego superkondensatora na podstawie jego charakterystyk ładowania i rozładowania. Urządzenie składa się ze sterowanego źródła prądowego do ładowania i rozładowywania superkondensatora, przetwornika analogowo-cyfrowego do pomiaru prądu i napięcia w trakcie eksperymentu oraz mikroprocesora do sterowania pomiarem i komunikacji z komputerem na którym...