Electrochemical detection of bacterial endotoxin lipopolysaccharide (LPS) on gold electrode modified with DAL-PEG-DK5-PEG-OH - Antimicrobial peptide conjugate - Publication - Bridge of Knowledge

Search

Electrochemical detection of bacterial endotoxin lipopolysaccharide (LPS) on gold electrode modified with DAL-PEG-DK5-PEG-OH - Antimicrobial peptide conjugate

Abstract

This work describes fabrication of gold electrodes modified with peptide conjugate DAL-PEG-DK5-PEG-OH that enables ultra-sensitive detection of lipopolysaccharide (LPS) isolated from the reference strain of Escherichia coli O26:B6. The initial step of the established procedure implies immobilization of the fully protected DAL-PEG-DK5-PEG-OH peptide on the surface of the gold electrode previously modified by cysteamine. Then side chain- and Fmoc-deprotection was performed in situ on the electrode surface, followed by its incubation in 1 % of BSA solution to block non-specific bindings sites before LPS detection. The efficiency of the modification was confirmed by X-ray Photoelectron Spectroscopy (XPS) measurements. Additionally, the cyclic voltammetry (CV) and electrochemical impendance spectroscopy (EIS) were employed to monitor the effectiveness of each step of the modification. The obtained results confirmed that the presence of the surface-attached covalently bound peptide DAL-PEG-DK5-PEG-OH enables LPS detection by means of CV technique within the range from 5 × 10−13 to 5 × 10−4 g/mL in PBS solution. The established limit of detection (LOD) for EIS measurements was 4.93 × 10−21 g/mL with wide linear detection range from 5 × 10−21 to 5 × 10−14 g/mL in PBS solution. Furthermore, we confirmed the ability of the electrode to detect LPS in a complex biological samples, like mouse urine and human serum. The effectiveness of the electrodes in identifying LPS in both urine and serum matrices was confirmed for samples containing LPS at both 2.5 × 10−15 g/mL and 2.5 × 10−9 g/mL.

Citations

  • 1

    CrossRef

  • 0

    Web of Science

  • 1

    Scopus

Authors (10)

Cite as

Full text

full text is not available in portal

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach
Published in:
TALANTA.The International Journal of Pure and Applied Analytical Chemistry no. 273,
ISSN: 0039-9140
Language:
English
Publication year:
2024
Bibliographic description:
Paulina K., Golda A., Ryl J., Pilarczyk-zurek M., Bereta G., Ossowski T., Lesner A., Koziel J., Prahl A., Niedziałkowski P.: Electrochemical detection of bacterial endotoxin lipopolysaccharide (LPS) on gold electrode modified with DAL-PEG-DK5-PEG-OH - Antimicrobial peptide conjugate// TALANTA.The International Journal of Pure and Applied Analytical Chemistry -,iss. 273 (2024), s.125881-
DOI:
Digital Object Identifier (open in new tab) 10.1016/j.talanta.2024.125881
Sources of funding:
Verified by:
Gdańsk University of Technology

seen 56 times

Recommended for you

Meta Tags