prof. dr hab. inż. Robert Jankowski
Employment
- Kierownik Studium Doktoranckiego at Faculty of Civil and Environmental Engineering
- Head of Department at Department of Building Engineering
- Deputy Director for Education, Quality & PQF, Doctoral School at Doctoral School
Research fields
Publications
Filters
total: 279
Catalog Publications
-
Pounding Between Superstructure Segments in Multi-Supported Elevated Bridge with Three-Span Continuous Deck Under 3D Non-Uniform Earthquake Excitation
PublicationReports after severe ground motions show that the earthquake-induced structural pounding may lead to significant damage in elevated bridges. The aim of this paper is to analyse pounding between superstructure segments of a highway elevated bridge with three-span continuous deck under 3D non-uniform earthquake excitation, which is induced by spatial seismic effects related to the propagation of seismic wave. The conditional stochastic...
-
Experimental Study on Effectiveness of a Prototype Seismic Isolation System Made of Polymeric Bearings
PublicationSeismic isolation is identified as one of the most popular and effective methods of protecting structures under strong dynamic excitations. Base isolators, such as Lead Rubber Bearings, High Damping Rubber Bearings, and Friction Pendulum Bearings, are widely used in practice in many earthquake-prone regions of the world to mitigate structural vibrations, and therefore minimize loss of life and property damage during seismic events....
-
Elastic and inelastic multi-storey buildings under earthquake excitation with the effect of pounding
PublicationW artykule przeprowadzono analizę różnic w liniowym i nieliniowym zachowaniu się budynków wielokondygnacyjnych podczas trzęsień ziemi z uwzględnieniem efektu zderzeń pomiędzy nimi. Analizę numeryczną przeprowadzono dla różnych wartości ekstremalnych przyspieszeń gruntu. Wyniki pokazują, iż zaimplementowanie nieliniowego modelu zachowania się budowli jest bardzo istotne w celu uzyskania dokładnej odpowiedzi konstrukcji.
-
Investigating the effects of structural pounding on the seismic performance of adjacent RC and steel MRFs
PublicationAn insufficient separation distance between adjacent buildings is the main reason for structural pounding during severe earthquakes. The lateral load resistance system, fundamental natural period, mass, and stiffness are important factors having the influence on collisions between two adjacent structures. In this study, 3-, 5- and 9-story adjacent reinforced concrete and steel Moment Resisting Frames (MRFs) were considered to investigate...
-
Influence of soil–structure interaction on seismic pounding between steel frame buildings considering the effect of infill panels
PublicationThe present research aims to study the influence of the soil-structure interaction (SSI) and existence or absence of masonry infill panels in steel frame structures on the earthquake-induced pounding-involved response of adjacent buildings. The study was further extended to compare the pounding-involved behavior versus the independent behavior of structures without collisions, focusing much on dynamic behavior of single frames....
-
Seismic Pounding Between Bridge Segments: A State-of-the-Art Review
PublicationEarthquake-induced structural pounding in bridge structures has been observed in several previous seismic events. Collisions occur at the expansion joints provided between adjacent decks or between the deck and abutment. Pounding between the structural elements may lead to severe damages and even to the unseating of the bridge in certain cases. Several investigations have been performed to study pounding in bridges under uniform...
-
Seismic pounding behavior of multi-story buildings in series considering the effect of infill panels
PublicationThe aim of the present paper is to study the influence of the infill panels on the seismic pounding response of adjacent structures in series. The contribution of the masonry infill has been simulated using equivalent diagonal compression struts. Steel frames have been assumed to have elastic-plastic behavior with 1% linear strain hardening. The dynamic contact analysis has been utilized where contact surface model (target and...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublicationStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
Non-linear FEM analysis of pounding-involved response of buildings under non-uniform earthquake excitation
PublicationThe aim of the paper is to show the results of the study investigating the influence of non-uniform earthquake excitation, due to spatial seismic effects connected with the propagation of seismic wave, on the pounding-involved response of two buildings. The three-dimensional non-linear FEM analysis has been conducted using the detailed models of colliding structures. Acceleration records for different structural supports have been...
-
Numerical study on pounding between two adjacent buildings under earthquake excitation
PublicationSeismic excitation, which results in large horizontal relative displacements, may cause collisions between two adjacent structures due to insufficient separation distance between them. Such collisions, known as earthquake-induced structural pounding, may induce severe damages. In this paper, the case of pounding between two adjacent buildings is studied by the application of single degree-of-freedom structural models. Impact is...
-
Earthquake-induced pounding between equal height multi-storey buildings considering soil-structure interaction
PublicationThe present paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated equal height buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using a suit of ground motions with different peak...
-
Pounding force response spectrum under earthquake excitation
PublicationW artykule przedstawiono możliwość wykorzystania spektrum siły zderzenia jako zaproponowanego przez autora narzędzia pomocnego przy projektowaniu budynków narażonych na zderzenia podczas trzęsień ziemi. Przedstawione wykresy spektrów pokazały, iż właściwy dobór parametrów budowli, takich jak szerokość przerwy pomiędzy budynkami, okres drgań własnych konstrukcji, liczba tłumienia, masa, współczynnik ciągliwości, czy też przesunięcie...
-
Experimental study on earthquake-induced pounding between structural elements made of different building materials
PublicationCelem artykułu jest pokazanie wyników dwóch eksperymentów dotyczących zderzeń pomiędzy elementami wykonanymi z różnych materiałów budowlanych, takich jak: stal, beton, drewno i ceramika. Pierwszy z nich polegał na zrzucaniu kul na płaską powierzchnię, drugi dotyczył zderzeń modeli konstrukcji poddanych wymuszeniom sejsmicznym na stole wstrząsowym. Wyniki testów pokazują, iż wpływ materiału elementów kolidujących ze sobą na zachowanie...
-
Non-linear FEM analysis of earthquake-induced pounding between the main building and the stairway tower of the Olive View Hospital
PublicationCelem artykułu jest dokładna, trójwymiarowa analiza MES dotycząca zderzeń pomiędzy budynkiem głównym a konstrukcją wolnostojącej klatki schodowej szpitala Olive View podczas trzęsienia ziemi San Fernando w roku 1971. Wyniki analizy pokazują, iż kolizje mogą prowadzić do znacznego wzrostu odpowiedzi lżejszej konstrukcji klatki schodowej, powodować uszkodzenia w miejscach kontaktu oraz potęgować uszkodzenia u podstawy tej budowli....
-
Linking of adjacent three-storey buildings for mitigation of structural pounding during earthquakes
PublicationThe reports after major earthquakes indicate that the earthquake-induced pounding between insufficiently separated buildings may lead to significant damage or even total collapse of structures. An intensive study has recently been carried out on mitigation of pounding hazards so as to minimize the structural damages or prevent collisions at all. The aim of this paper is to investigate the effectiveness of the method when two adjacent...
-
Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures
PublicationStructural pounding has been observed in many previous earthquakes due to insufficient gap commonly provided between adjacent structures. The collisions usually generate large impact forces and short duration acceleration pulses which may result in significant damage to the colliding buildings. Because of that, earthquake induced structural pounding has been intensively studied and investigated for the last three decades. Results...
-
Earthquake-induced pounding between equal height buildings with substantially different dynamic properties
PublicationZderzenia pomiędzy konstrukcjami budowlanymi podczas trzęsień ziemi mogą prowadzić do znacznych uszkodzeń czy nawet całkowitego zniszczenia. Celem niniejszego artykuły jest analiza zderzeń pomiędzy budynkami o jednakowej wysokości i różnych parametrach dynamicznych. W artykule przedstawiono wyniki badań numerycznych przeprowadzonych na nieliniowych modelach dyskretnych o skupionych masach z wykorzystaniem nieliniowego modelu lepkosprężystego...
-
Analytical expression between the impact damping ratio and the coefficient of restitution in the non-linear viscoelastic model of structural pounding
PublicationWyniki wcześniejszych badań pokazują, iż nieliniowy model lepko-sprężysty zderzeń konstrukcji budowlanych podczas trzęsień ziemi najdokładniej symuluje siłę zderzenia w czasie kontaktu oraz odpowiedź konstrukcji. Celem niniejszego artykułu jest wyprowadzenie wzoru na zależność pomiędzy liczbą tłumienia zderzenia (parametr wspomnianego modelu) a współczynnikiem odbicia, który jest parametrem często stosowanym i analizowanym w literaturze....
-
Non-linear viscoelastic modelling of earthquake-induced structural pounding
PublicationCelem artykułu jest analiza nieliniowego lepko-sprężystego modelu siły zderzenia, który ma zastosowanie do symulacji zderzeń pomiędzy konstrukcjami budowlanymi podczas trzęsień ziemi. Efektywność modelu sprawdzono poprzez porównanie wyników symulacji numerycznych z wynikami eksperymentalnymi. Wyniki pracy pokazują, iż w stosunku do innych modeli zderzeń, nieliniowy model lepko-sprężysty umożliwia najdokładniejszą symulację siły...
seen 7730 times