Filters
total: 745
filtered: 205
Search results for: ANTI-SURGE VALVE
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Simulation of ship turning circle test for ballast and full load conditions
Open Research DataThe data show the results of the turning circle spiral test for the simplified ship model, taking into account two states of loading: ballast and full load. During the circulation test, the manoeuvrability of the vessel is tested.
-
Simulation of ship spiral test for ballast and full load conditions
Open Research DataThe data show the results of the spiral test for the simplified ship model, taking into account two states of loading: ballast and full load. The data set contains the results of time simulation for sea state 10 on the Beaufort scale: changes in rudder angle delta_tab[deg]; angular velocity r_tab[deg/s]; surge velocity u_tab (m/s); sway velocity v_tab...
-
SEM micrographs of the austenitic stainless steel corrosion in asphalt fumes
Open Research DataThe dataset contains the scanning electron microscopy (SEM) studies of the austenitic stainless steels: AISI 304, AISI 316, AISI 321 and duplex stainless steel AISI 2205. The samples were polished and exposed to the installation carrying asphalt fumes at elevated temperatures (approx. ~210-240 Celsius). The exposition duration was three months. Some...
-
The electrochemical impedance spectroscopy studies of cataphoretic-grown epoxy-based coatings
Open Research DataThe dataset contains electrochemical impedance spectroscopy spectra collected for epoxy-based cataphoretic coatings in order to determine the offered anti-corrosion protection. Particular spectra pertain to the coatings applied for the different magnitude of polarization potential imposed, namely 10V, 20V and 30V. The results were obtained within the...
-
Flow cytometry analysis of DNA DSBs in telomerase positive and negative cell lines after treatment with TXT2 and TXT4
Open Research DataFlow cytometry analysis of DNA DSBs in telomerase positive (A549, H460) and negative (NHBE2594, U2OS) cell lines after treatment with equitoxic concentrations of TXT2 and TXT4. MTX and DMSO were used as positive and negative controls, respectively.
-
The influence of external interference on AFM imaging, the use of a protective helmet
Open Research DataThis collection is of purely practical importance, showing how the presence of external disturbances can adversely affect the quality of imaging with an atomic force microscope. For this reason, it is also advisable to provide a link to a workshop-like study [1] as well as a huge number of commercial solutions available after entering the keyword "AFM...
-
Fuel cell noise data
Open Research DataMeasurement data of Hydrogen PEM fuel cels. The voltage fluctuations were measured over single cels of stack of 10 cels.
-
SEM micrographs of the topography of Cu-Sn-TiO2 nanocomposite coatings
Open Research DataThe dataset contains the scanning electron microscopy (SEM) micrographs of nanocomposite Cu-Sn-TiO2 coatings electrodeposited from oxalic acid bath containing Cu and Sn salts as well as TiO2 nanoparticles under various treatments: mechanical stirring, ultrasonic or none. The details of the electrodeposition process are presented in the readme file attached...
-
The AFM micrographs and impedance study of epoxy coatings after exposure in corrosive media
Open Research DataThe dataset contains Atomic Force Microscopy (AFM) images and local impedance measurements of epoxy organic coating used as anti-corrosion protection, before and after 2-month exposure to sodium chloride solution. Additionally, there two local impedance spectra recorded after the coating exposure. The first one was recorded on intact coating surface,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...