Filters
total: 20
filtered: 19
Chosen catalog filters
Search results for: REPLACEMENT LIQUIDS FOR E-CIGARETTES
-
Ultrasound-Assisted Solvent Extraction of a Porous Membrane Packed Sample for the Determination of Tobacco-Specific Nitrosamines in the Replacement Liquids for E-Cigarettes
PublicationThe content of tobacco-specific nitrosamines (TSNAs) possessing carcinogenic properties has been an important area of research since replacement liquids were introduced for e-cigarettes. A method for determining N′-nitrosonornicotine (NNN), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N′-nitrosoanatabine (NAT), and N′-nitrosoanabasine (NAB) in replacement liquids for electronic cigarettes was developed using liquid chromatography–tandem...
-
An evaluation of sucrose as a possible contaminant in e-liquids for electronic cigarettes by hydrophilic interaction liquid chromatography–tandem mass spectrometry
PublicationThe influence of sucrose combustion products on smoking and nicotine addiction is still controversial because the presence of the sucrose may be treated as a source of aldehydes and organic acids. In e-liquids used as refills for electronic cigarettes, which are made primarily of poly(propylene glycol), glycerine and ethanol, sucrose may be present at trace levels, and its impact on mainstream smoke formation, and hence on human...
-
An evaluation of sucrose as a possible contaminant in e-liquids for electronic cigarettes by hydrophilic interaction liquid chromatography–tandem mass spectrometry
Publication -
Determination of Glycerol, Propylene Glycol, and Nicotine as the Main Components in Refill Liquids for Electronic Cigarettes
PublicationRefill liquids for electronic cigarettes are an important area of research due to the health safety and quality control of such products. A method was developed for the determination of glycerol, propylene glycol, and nicotine in refill liquids using liquid chromatography, coupled with tandem mass spectrometry (LC-MS/MS) in multiple reaction monitoring (MRM) mode with electrospray ionisation (ESI). Sample preparation was based...
-
“Dilute & Shoot” approach for rapid determination of trace amounts of nicotine in zero-level e-liquids by reversed phase liquid chromatography and hydrophilic interactions liquid chromatography coupled with tandem mass spectrometry-electrospray ionization
PublicationTwo analytical procedures are proposed where HILIC and RPLC techniques are coupled with tandem mass spectrometry detection for rapid determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Samples are prepared on the basis of the approach “dilute & shoot” which makes this important step quick and not complicated. The chromatographic separation was carried out on a Zorbax XDB column (RPLC method)...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part II: Gas-chromatography–mass spectrometry analysis
PublicationFlavouring compounds are an essential part of e-liquid products for cigarettes. In general, they are regarded as safe for ingestion, but they may have unrecognized risks when they are inhaled. In some cases, manufactures do not currently abide by the Tobacco Products Directive (2014/40/EU) and do not declare the detailed contents of e-liquids on their labels. To help evaluate the health impact of flavouring substances, there is...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis
PublicationLiquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI–MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace® Ultracore™ SuperC18™ (100 × 2.1 mm, 2.5 μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple “dilute & shoot” approach...
-
Evaluation of flavour profiles in e-cigarette refill solutions using gas chromatography–tandem mass spectrometry
PublicationMany flavour compounds that are present in e-liquids for e-cigarettes are responsible for specific tastes and smoking sensations for users. Data concerning content and specific types of flavours is often limited and unknown to users. The aim of the research was to define and compare flavour profiles of e-liquids with the same group taste from different manufacturers. Gas chromatography coupled with tandem mass spectrometry (GC–MS/MS)...
-
Perspectives on the replacement of harmful organic solvents in analytical methodologies: a framework toward the implementation of a generation of eco-friendly alternatives
PublicationVolatile organic solvents derived from non-renewable fossil feedstocks are commonplace in analytical laboratories. In spite of their convenient performance in countless unit operations, their environmental, health and safety issues represent a major area of concern. The progressive replacement of organic solvents obtained from fossil resources by eco-friendly alternatives would involve remarkable advances within the framework of...
-
Lubricant property and rolling contact fatigue test of oil-in-water emulsion type HFA-E and oil Total Azolla 46 as working liquids in hydraulic systems
PublicationW artykule scharakteryzowano i opisano wyniki badań własności smarnych wody destylowanej, emulsji wodno-olejowej typu HFA-E (1% oleju w wodzie) sporządzonej na bazie koncentratu Isosynth VX110BF, oleju Total Azolla 46 i samego koncentratu Isosynth VX110BF (tylko dla porównania z olejem, emulsją i wodą). W artykule pokazano wyniki badań pittingu z użyciem wody, emulsji i oleju jako środków smarnych. Ponadto w artykule przedstawiono...
-
“Dilute & Shoot” approach for rapid determination of trace amounts of nicotine in zero-level e-liquids by reversed phase liquid chromatography and hydrophilic interactions liquid chromatography coupled with tandem mass spectrometry-electrospray ionization
Publication -
Porównanie własności smarnych wody, emulsji oleju w wodzie typu HFA-E oraz oleju Total Azolla 46 jako czynników roboczych w układach hydraulicznych = Comparison of the lubricant property of water oil-in-water emulsion type HFA-E and oil total Azolla 46 as working liquids in hydraulic systems
PublicationW artykule scharakteryzowano i opisano wyniki badań własności smarnych wody destylowanej, 1% emulsji oleju w wodzie typu HFA-E sporządzonej na bazie koncentratu do tworzenia emulsji Isosynth VH110BF, oleju Total Azolla 46 oraz, w celach porównawczych, samego koncentratu Isosynth VH110BF. Przedstawiono również wyniki badań powierzchniowego zużycia zmęczeniowego (pittingu), dla wyżej wymienionych czynników smarnych. Emulsja oleju...
-
Power balance in hydraulic satellite motors supplied with oil and HFA-E emulsion
PublicationMineral oil and HFA-E emulsion are liquids which differ in viscosity, density and lubricant properties. Therefore, supplying hydraulic satellite motors with these liquids, differences between quantity of hydraulic, volumetric and mechanical losses are observed. These losses influence efficiency of conversion of hydraulic energy into mechanical energy and thereby power balance of motors.
-
Losses and power balance in hydraulic satellite motor supplied with oil and HFA-E emulsion
PublicationMineral oil and HFA-E emulsion are liquids which differ in viscosity, density and lubricant properties. Therefore, supplying hydraulic satellite motor with these liquids, differences between quantity of hydraulic, volumetric and mechanical losses are observed. These losses influence efficiency of conversion of hydraulic energy into mechanical energy and thereby power balance of motor. The research of satellite motor has been conducted...
-
Concentration levels of selected analytes in the gas phase of an e-cigarette aerosol
PublicationThe aerosols generated from e-cigarettes are composed of liquid and gas phases resulting from vapourized e-liquid. The apportioning of substances from e-liquid into the liquid and gas phases during e-cigarette use has not been extensively studied. Partitioning of e-liquid components between the gas and the liquid phase of the aerosol influences the substances inhaled and exhaled by the users, leading to second-hand exposure. It...
-
Relatively high-Seebeck thermoelectric cells containing ionic liquids supplemented by cobalt redox couple
PublicationMeanwhile no general and reliable equation determining the Seebeck coefficient (S e ) and involving electro-chemical reaction effects was derived for solutions. We reported the database of 15,000 ionic liquids supplemented by three different redox couple systems: 0.01 mol/l Co 3+/2+ (bpy) 3 , 0.01 mol/l I 3-/3I- and 0.2 mol/l 3- /3I- , and the corresponding estimated Seebeck coefficients. We also reported methods for estimating...
-
New approach for e-cigarette aerosol collection by an original automatic aerosol generator utilizing melt-blown non-woven fabric
PublicationCurrently, there is lack of standardized conditions for the collection and analysis of e-cigarette (EC) aerosol. Considering the urgent need for the development of these guidelines, a procedure for EC aerosol analysis was developed. A novel automatic e-cigarette aerosol generator was designed. For the first time, melt-blown non-woven fabric was applied for the effective uptake of compounds released from vaporized e-liquid. The...
-
Structural Factors Affecting Cytotoxic Activity of (E)-1-(Benzo[d ][1,3]oxathiol-6-yl)-3-phenylprop-2-en-1-one Derivatives
PublicationDerivatives of (E)-1-(5-alkoxybenzo[d][1,3]oxathiol-6-yl)-3-phenylprop-2-en-1-one (1) demonstrated exceptionally high in vitro cytotoxic activity, with IC50 values of the most active derivatives in the nanomolar range. To identify structural fragments necessary for the activity, several analogs deprived of selected fragments were prepared, and their cytotoxic activity was tested. It was found that the activity depends on combined effects...
-
In silico modelling for predicting the cationic hydrophobicity and cytotoxicity of ionic liquids towards the Leukemia rat cell line, Vibrio fischeri and Scenedesmus vacuolatus based on molecular interaction potentials of ions
PublicationIn this study we present prediction models for estimating in silico the cationic hydrophobicity and the cytotoxicity (log [1/EC50]) of ionic liquids (ILs) towards the Leukemia rat cell line (IPC-81), the marine bacterium Vibrio fischeri and the limnic green algae Scenedesmus vacuolatus using linear free energy relationship (LFER) descriptors computed by COSMO calculations. The LFER descriptors used for the prediction model (i.e....