Filters
total: 255
filtered: 242
-
Catalog
Chosen catalog filters
Search results for: SCATTERING PARAMETERS
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublicationThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...
-
Greedy Multipoint Model-Order Reduction Technique for Fast Computation of Scattering Parameters of Electromagnetic Systems
PublicationThis paper attempts to develop a new automated multipoint model-order reduction (MOR) technique, based on matching moments of the system input–output function, which would be suited for fast and accurate computation of scattering parameters for electromagnetic (EM) systems over a wide frequency band. To this end, two questions are addressed. Firstly, the cost of the wideband reduced model generation is optimized by automating a...
-
Fast frequency sweep based on the model order reduction technique for calculating scattering parametersjinjFDFDj
PublicationArtykuł prezentuje ulepszoną, efektywną metodę przemiatania częstotliwościowego dla metody FDFD. Liczba równań opisujących analizowaną strukturę jest redukowana za pomocą metody redukcjirzędu modeli, a następnie macierz wynikowa jest diagonalizowana. Kosztowne czasowo odwracanie dużych macierzy jest zastąpione prostym mnożeniem małej macierz diagonalnej przez wektor. Zaprezentowana metoda przemiatania częstotliwościowego może...
-
Estimation of optical parameters of highly scattering materials by time-of-flight spectroscopy.
PublicationPrzedstawiono metody wyznaczania podstawowych parametrów materiałów silnie rozpraszających światło na podstawie pomierzonego rozkładu czasu przelotu krótkich impulsów laserowych. W algorytmie wykorzystano metodę Monte Carlo i metodę dyfuzji do opisu propagacji światła. Oszacowano dokładność oszacowywania tych parametrów.
-
Automatic system for optical parameters measurements of biological tissues
PublicationIn this paper a system allowing execution of automatic measurements of optical parameters of scattering materials in an efficient and accurate manner is proposed and described. The system is designed especially for measurements of biological tissues including phantoms, which closely imitate optical characteristics of real tissue. The system has modular construction and is based on the ISEL system, luminance and color meter and...
-
Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering
PublicationWe present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa, reduced scattering coefficient µs',...
-
Kriging Models for Microwave Filters
PublicationSurrogate modeling of microwave filters’ response is discussed. In particular, kriging is used to model either the scattering parameters of the filter or the rational representation of the filter’s characteristics. Surrogate models for these two variants of kriging are validated in solving a microwave filter optimization problem. A clear advantage of surrogate models based on the rational representation over the models based on scattering...
-
Porous Phantoms Mimicking Tissues—Investigation of Optical Parameters Stability Over Time
PublicationOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods, while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom in optical system. Measurements were performed in multiple series with an interval...
-
Analytical calculations of scattering lengths for a class of long-range potentials of interest for atomic physics
PublicationWe derive two equivalent analytical expressions for an $l$th partial-wave scattering length $a_{l}$ for central potentials with long-range tails of the form % \begin{math} \displaystyle V(r)=-\frac{\hbar^{2}}{2m}\frac{Br^{n-4}}{(r^{n-2}+R^{n-2})^{2}} -\frac{\hbar^{2}}{2m}\frac{C}{r^{2}(r^{n-2}+R^{n-2})}, \end{math} % ($r\geqslant r_{s}$, $R>0$). % For $C=0$, this family of potentials reduces to the Lenz potentials discussed in...
-
Finite element/mode-matching analysis of ferrite/dielectric line junctions of arbitrary cross-section
PublicationThis paper is focused on the analysis of line junctions obtained as a cascade of dielectric and ferrite guides of arbitrary cross-section. The main application of such structures is nonreciprocal devices such as isolators, circulators, or phase shifters. The efficient finite element/mode-matching approach is proposed to the analysis of such structures. In this approach, thefiniteelementmethod is applied todetermine propagation...
-
Analysis of the macrostructure of the fuel spray atomized with marine engine injector
PublicationOne of the main problem influencing the combustion process in the cylinder of the marine engine is an fuel spray phenomena. The parameters describing the shape of the fuel spray are named macro parameters. This article presents the research results of the macrostructure parameters of the fuel spray atomized with the marine engine injector. The research were carried out by optical visualization measurement method of Mie scattering....
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublicationIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublicationThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublicationThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublicationThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Zero-Pole Electromagnetic Optimization
PublicationA fast technique for the full-wave optimization of transmission or reflection properties of general linear timeinvariant high-frequency components is proposed. The method is based on the zeros and poles of the rational function representing the scattering parameters of the device being designed and it is the generalization of the technique developed for the design by optimization of microwave filters. The performance of the proposed...
-
Surface active fatty acid ILs: Influence of the hydrophobic tail and/or theimidazolium hydroxyl functionalization on aggregates formation
PublicationNine structurally-related fatty acid ionic liquids have been prepared and their thermal behavior as well as their ability to self-assemble in water has been investigated. The thermal properties were studied by thermal gravimetric analysis (TGA) and differential scanning calorimetry (DSC), while the aggregation behavior was analyzed by tensiometry, isothermal titration calorimetry (ITC), conductometry, dynamic light scattering (DLS),...
-
Zero-Pole Space Mapping for CAD of Filters
PublicationIn this paper, we propose a new space-mapping technique tailored to the CAD of microwave filters. The goal of space mapping is to achieve a satisfactory design with the minimal number of fine model evaluations. In our approach, the filter is represented by a rational function. To quickly align the coarse and fine models, and to speed up the direct optimization of the coarse model, we propose matching the zeros and poles of a rational...
-
Designing acoustic scattering elements using machine learning methods
PublicationIn the process of the design and correction of room acoustic properties, it is often necessary to select the appropriate type of acoustic treatment devices and make decisions regarding their size, geometry, and location of the devices inside the room under the treatment process. The goal of this doctoral dissertation is to develop and validate a mathematical model that allows predicting the effects of the application of the scattering...
-
Measurements of fundamental properties of homogeneous tissue phantoms
PublicationWe present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters’ estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities....