displaying 1000 best results Help
Search results for: UNSTEADY PIPE FLOW
-
An advanced thermal-FSI approach of an evaporation of air heat pump
PublicationThe paper presents selected problems of numerical modeling of an advanced thermal-FSI approach of evaporator of air heat pomp. The example of a fin-tube evaporator has been studied, focusing on obtaining of heat exchanger characteristics applying two-phase flow model for the in-tube refrigerant flow. Special attention is given to heat transfer between separated medium for different air velocity and changed refrigerant mass flow...
-
Design and experimental investigations of a cylindrical microjet heat exchanger for waste heat recovery systems
PublicationCompact heat exchangers have more and more applications in many areas, including the HVAC, food and petrochemical industry. This paper describes the development of heat exchanger technology for waste heat recovery (WHR) from a range of processes. Case-study testing shows that the proposed heat exchanger can successfully enhance heat transfer and recover waste heat in a range of applications making them economically, environmentally and...
-
Data set generation at novel test-rig for validation of numerical models for modeling granular flows
PublicationSignificant effort has been exerted on developing fast and reliable numerical models for modeling particulate flow; this is challenging owing to the complexity of such flows. To achieve this, reliable and high-quality experimental data are required for model development and validation. This study presents the design of a novel test-rig that allows the visualization and measurement of particle flow patterns during the collision...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=2.0, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=2.1, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.0, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=5.7, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=5.5, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=2.8, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.20, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.30, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Investigation of the flow, heat and mass transfer and emissions in pulverized fuel fired boiler using physical and numerical modeling.
PublicationPraca przedstawia wykorzystanie techniki modelowania fizycznego trójwymiarowego oraz obliczeń numerycznych umożliwiających symulację rzeczywistych procesów spalania paliw stałych i gazowych w urządzeniach energetycznych. Dodatkowo wyniki obliczeń porównano z wynikami modelowania fizycznego oraz pomiarów na obiekcie rzeczywistym.
-
A semi-empirical method for calculation of flow boiling heat transfer coefficients for conventional channels and small diameter tubes
PublicationW pracy przedstawiono rozważania na temat modelowania dwufazowego przepływu wrzącego w kanałach konwencjonalnych i w kanałach o małej średnicy. Przedstawiono modyfikację korelacji zaproponowanej wcześniej przez J. Mikielewicza na podstawie nowych danych eksperymentalnych, uzyskanych dla kanałów o małej średnicy. Bank danych obejmował ponad 460 punktów pomiarowych dla czynników R141b, R134a, R113, R123, R12, R11 i wody. Uzyskano...
-
Improved semi-empirical method for determination of heat transfer coefficient in flow boiling in conventional and small diameter tubes
PublicationPraca dotyczy przedstawienia poprawionego modelu umożliwiającego wyznaczanie współczynnika przejmowania ciepła w kanałach o małych średnicach jaj i tych tradycyjnych. Model zweryfikowano na 6 czynnikach chłodnuiczych uzyskując bardzo zadowalającą zgodność.
-
Direct Current Atmospheric Pressure Microdischarge Generated between a Miniature Flow Helium Microjet and a Flowing Liquid Cathode
Publication -
Decolorization of organic dyes solution by atmospheric pressure glow discharge system working in a liquid flow-through mode
Publication -
The Acute Effects of External Compression With Blood Flow Restriction on Maximal Strength and Strength-Endurance Performance of the Upper Limbs
Publication -
Does Post-Activation Performance Enhancement Occur during the Bench Press Exercise under Blood Flow Restriction?
Publication -
Modeling of heat and fluid flow in granular layers using high-order compact schemes and volume penalization method
Publication -
Does blood flow restriction influence the maximal number of repetitions performed during the bench press? A pilot study
Publication -
A robust optimization model for affine/quadratic flow thinning: A traffic protection mechanism for networks with variable link capacity
Publication -
Best State Estimate for the Phase Angles of Busbars in Power Systems via Circuit Modeled with DC Load Flow
Publication -
Nowy system diagnostyki cieplno-przepływowej obiektów energetycznych.The new system of power units thermal and flow diagnostics.
PublicationPrzedstawiono zmodernizowany system diagnostyki urządzeń składowych obiegów cieplnych bloków energetycznych. Wskazano na zalety zastosowania do tego sztucznych sieci neuronowych (SSN). Opisano dokładność SSN zastosowanych do poszukiwania typów degradacji geometrycznych i do rozpoznawania rozmiarów degradacji geometrycznych.
-
Badania wrzenia R22 w rurkach z powłoką porowatą. Investigation of R22 flow boiling in porous tubes.
PublicationW pracy przedstawiono wyniki pomiarów współczynnika przejmowania ciepła przy wrzeniu w przepływie R22 w poziomej rurce z aluminiową powłoką porowatą. Otrzymane dane odniesiono do wyników uzyskanych dla gładkiej stalowej rurki oraz rurki typu microfin. Rurka gładka i z powłoką porowatą była wykonana ze stali nierdzewnej o grubości ścianki 0.6 mm. Grubość powłoki porowatej wynosiła 0,2 mm. Eksperymenty prowadzono przy stopniu suchości...
-
Application of Particle Image Velocimetry method for monitoring the volume changes during silo flow on the basis of X-radiographs
PublicationW artykule przedstawiono wyniki badań nad zastosowaniem techniki pomiarowej PIV (Particle Image Velocimetry) do analizy zmian objętościowych zachodzących w materiale sypkim w czasie opróżniania silosu prostokątnego. Jako mateirły do analizy wykorzystano cyfrowe radiografy uzyskane z kontynualnej rejestracji z użyciem systemu tomografii promieni X. Szcególny nacisk położono na analizę zmian objętościowych zachodzącyh w kanale przepływu.
-
Experimental investigation of M-shape heat transfer coefficient distribution of R123 flow boiling in small-diameter tubes
PublicationW publikacji przedstawiono wyniki badań wrzenia czynnika R123 w srebrnych rurkach o małych średnicach (średnice wewnętrzne wynosiły odpowiednio 1.15 mm i 2.3 mm). Badania przeprowadzono w szerokim zakresie stopnia suchości pary (0.01-0.9), gęstości strumienia masy (650-3000 kg/(m2s)) oraz gęstości strumienia ciepła (40-80 kW/m2). W badaniach wykazano, że istnieją dwa lokalne maksima współczynnika przejmowania ciepła w jego profilu...
-
Double-diffusive natural convection energy transfer in magnetically influenced Casson fluid flow in trapezoidal enclosure with fillets
PublicationThe prime motive of this disquisition is to deal with mathematical analysis of natural convection energy transport driven by combined buoyancy effects of thermal and solutal diffusion in a trapezoidal enclosure. Casson fluid rheological constitutive model depicting attributes of viscoelastic liquids is envisioned. The influence of the inclined magnetic field governed by Lorentz field law is also considered. To raise the essence...
-
Inverse method for axisymmetric and blade-to-blade viscous flow models in cylindrical coordinates using stream-function transformation
PublicationZaproponowano nową metodę odwrotną rozwiązywania dwuwymiarowych zagadnień projektowych we współrzędnych cylindrycznych. Użyto współrzędnych funkcji prądu uzależniając kształt opływanej geometrii od kształtu linii prądu. Metodę zwalidowano. Pokazano zastosowanie do przepływów osiowosymetrycznych jak i na powierzchniach cylindrycnych.