Search results for: BLANK PROBLEMS
-
Troubleshooting of the determination of bisphenol A at ultra-trace levels by liquid chromatography and tandem mass spectrometry
PublicationDetermination of trace amounts of bisphenol A (BPA) may cause problems mainly related to the presence of BPA in solvents (even in LC-MS grade), laboratory vessels, and plastic equipment used for sample preparation. Variable and sometimes significant amounts of BPA present in the background cause problems in obtaining good repeatability of measurements at the ultra-trace levels. Such observations (i.e., poor repeatability of results)...
-
Curing behavior of epoxy/Fe 3 O 4 nanocomposites: A comparison between the effects of bare Fe 3 O 4 , Fe 3 O 4 /SiO 2 /chitosan and Fe 3 O 4 /SiO 2 /chitosan/imide/phenylalanine-modified nanofillers
PublicationIn this study, Fe3O4 magnetic nanoparticles (MNPs) were synthesized (B-MNP) and then modified with SiO2 to form Fe3O4/SiO2 core/shell MNPs. The Fe3O4/SiO2 MNPs were chemically functionalized with chitosan so as to gain Fe3O4/SiO2/Chitosan (CH-MNP). The CH-MNP was functionalized with a macromolecule containing imide and phenylalanine precursors to gain Fe3O4/SiO2/Chitosan/imide/phenylalanine based MNPs (CH-IM-MNP). The differences...
-
Methodology of Selecting the Optimal Receptor to Create an Electrochemical Immunosensor for Equine Arteritis Virus Protein Detection
PublicationThe study reports a methodology of selecting the optimal receptor to create an electrochemical immunosensor for equine arteritis virus (EAV) protein detection. The detection was based on antigen recognition by antibodies immobilized on gold electrodes. Modification steps were controlled by electrochemical impedance spectroscopy and cyclic voltammetry measurements. In order to obtain the impedance immunosensor with the best parameters,...
-
Methodology of Selecting the Optimal Receptor to Create an Electrochemical Immunosensor for Equine Arteritis Virus Protein Detection
PublicationThe study reports a methodology of selecting the optimal receptor to create an electrochemical immunosensor for equine arteritis virus (EAV) protein detection. The detection was based on antigen recognition by antibodies immobilized on gold electrodes. Modification steps were controlled by electrochemical impedance spectroscopy and cyclic voltammetry measurements. In order to obtain the impedance immunosensor with the best parameters,...
-
Cure kinetics of epoxy/MWCNTs nanocomposites: Nonisothermal calorimetric and rheokinetic techniques
PublicationNonisothermal calorimetric and isothermal rheokinetic analyses were used to study cure kinetics of epoxy/anhydride systems containing very low concentration of pristine and amine-functionalized multiwalled carbon nanotubes (MWCNTs). Isoconversional methods were applied in calorimetric modeling of cure kinetics. Eα vs. α dependency and autocatalytic nature of curing were identified for both types of nanocomposites by isoconversional...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Ni/cerium Molybdenum Oxide Hydrate Microflakes Composite Coatings Electrodeposited from Choline Chloride: Ethylene Glycol Deep Eutectic Solvent
PublicationCerium molybdenum oxide hydrate microflakes are codeposited with nickel from a deep eutectic solvent-based bath. During seven days of exposure in 0.05 M NaCl solution, the corrosion resistance of composite coating (Ni/CeMoOxide) is slightly reduced, due to the existence of some microcracks caused by large microflakes. Multielemental analysis of the solution, in which coatings are exposed and the qualitative changes in the surface...
-
New Transparent Flame-Retardant (FR) Coatings Based on Epoxy-Aluminum Hypophosphite Nanocomposites
PublicationThe present study investigated the flame-retardant (FR) effect of transparent epoxy coating containing aluminum hypophosphite (AHP) nanoparticles (NPs) on polylactic acid (PLA) sheets used as a typical model of combustible polymeric material. First, AHP NPs (≤60 nm) were prepared by a specific two-stage wet milling process and deeply analyzed (morphology, thermal/mechanisms of degradation under nitrogen and air). The thermal properties...
-
Thermal-Resistant Polyurethane/Nanoclay Powder Coatings: Degradation Kinetics Study
PublicationIn the present study, thermal degradation kinetics of polyurethane (PU) powder coatings reinforced with organo-modified montmorillonite (OMMT) was investigated. PU nanocomposites were prepared in different concentrations of 1, 3, and 5 wt.% of OMMT via the extrusion method. The microstructure of the nanocomposites was observed by scanning electron microscope (SEM) illustrating uniform dispersion of OMMT nano-clay platelets in the...
-
Green capsule phase microextraction employing hydrophobic monolithic sol-gel octadecyl siloxane platforms for the monitoring of organophosphorus pesticides in environmental water samples
PublicationIn this study, a novel, facile and green capsule phase microextraction (CPME) method is presented for the extraction and preconcentration of organophosphorus pesticides (i.e., chlorpyrifos, disulfoton, ethoprophos, fenchlorphos, prothiofos, and parathion-methyl) from environmental water samples. Monolithic sol-gel octadecyl siloxane (sol-gel C18) sorbent encapsulated within porous polypropylene capsules was synthesized, characterized,...
-
Long-Term Stability of Benzodiazepines and Z-Hypnotic Drugs in Blood Samples Stored at Varying Temperatures
PublicationBenzodiazepines (BZDs) and Z-drugs are among the most commonly prescribed pharmaceuticals in the world and are considered standard care for various mental illnesses and for treatment of sleeping and anxiety disorders, alcohol withdrawal, muscle spasms and epilepsy. Some BZDs are not allowed as pharmaceuticals in many countries, and they are used as "designer benzodiazepines" (DBZDs). All these compounds are typically screened in...
-
Polyurethane/Silane-Functionalized ZrO2 Nanocomposite Powder Coatings: Thermal Degradation Kinetics
PublicationA polyurethane (PU)-based powder coating reinforced with vinyltrimethoxysilane (VTMS)-functionalized ZrO2 nanoparticles (V-ZrO2) for thermal stability was developed. Chemical structure, microstructure and thermal degradation kinetics of the prepared coatings were investigated. The peak of aliphatic C–H vibrating bond in the Fourier transform infrared (FTIR) spectrum of V-ZrO2 was a signature of VTMS attachment. Scanning electron...
-
Acid-aided epoxy-amine curing reaction as reflected in epoxy/Fe3O4 nanocomposites: Chemistry, mechanism, and fracture behavior
PublicationThis work seeks to answer the question whether or not the presence of acid functional groups accelerate epoxyamine curing reaction. Epoxy/Fe3O4 nanocomposite was considered as a case, where discussions are based on chemistry, mechanism behind curing reactions and fracture behavior influenced by acid assistance to crosslinking. Fe3O4 magnetic nanoparticles (MNPs) with nanosilica decorative layer (B-MNP) were synthesized and subsequently...
-
Epoxy/Ionic Liquid-Modified Mica Nanocomposites: Network Formation–Network Degradation Correlation
PublicationWe synthesized pristine mica (Mica) and N-octadecyl-N’-octadecyl imidazolium iodide (IM) modified mica (Mica-IM), characterized it, and applied it at 0.1–5.0 wt.% loading to prepare epoxy nanocomposites. Dynamic differential scanning calorimetry (DSC) was carried out for the analysis of the cure potential and kinetics of epoxy/Mica and epoxy/Mica-IM curing reaction with amine curing agents at low loading of 0.1 wt.% to avoid particle...
-
Main complications connected with detection, identification and determination of trace organic constituents in complex matrix samples
PublicationIt is well known that some problems with the determination of organic analytes at trace level can occur. This issue is connected with contamination during each stage of the analytical procedure from sampling to sample preparation up to chromatographic analysis, which often leads to false-positive or overestimated results. Another problem associated with determination of analytes occurs at trace- and ultra-trace level is a background...