Search results for: PASSIVE FLUX SAMPLER
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublicationThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
PublicationNa Univeristy of Portsmouth (UK) opracowano próbnik pasywny typu Chemcatcher, który może być stosowany do długotrwałego monitoringu organicznych zanieczyszczeń wody. Na działanie wszystkich próbników pasywnych wpływ mają warunki środowiskowe takie jak np. ruch wody czy temperatura. Przed użyciem próbnika Chemcatcher w badaniach polowych wymagana więc była wcześniejsza kalibracja w laboratorium. Przedstawiono wyniki serii doświadczeń...
-
Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water
PublicationZaprojektowano nową obudowę próbnika typu Chemcatcher, tzw. próbnik typu Chemcatcher drugiej generacji. Większość badań kalibracyjnych przeprowadzono stosując próbnik typu Chemcatcher pierwszej generacji. Dlatego zbadano wpływ obudowy próbnika typu Chemcatcher na jego działanie.
-
Small-scale passive emission chamber for screening studies on monoterpene emission flux from the surface of wood-based indoor elements
PublicationAnalysis of literature data published in the last fewyears leads to the conclusion that in the process of assessment of emission flux of organic compounds emitted from different types of equipment and finishing materials, new types of devices, among which small-scale passive emission chambers for the performance of in-situ research are designed and applied on a larger scale. These devices can be successfully used for the assessment...
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublicationThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublicationAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Unconventional and user-friendly sampling techniques of semi-volatile organic compounds present in an indoor environment: An approach to human exposure assessment
PublicationThe commonly applied solutions used to assess the potential risk of human exposure to semi-volatile organic compounds (SVOCs) are based on the investigation of biological samples collected in an invasive or non-invasive manner. For SVOCs, which are typically introduced to humans through the respiratory system, dermal adsorption, or digestive system, sampling solutions generally used in the indoor environments are classified as...
-
Heat transfer and pressure drop characteristics of the silicone-based plate heat exchanger
PublicationThe paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported...
-
Heat transfer intensification by enlarged surface roughness in the plate heat exchanger
PublicationIn the paper an experimental analysis of passive heat transfer intensification technique employed in the case of the plate heat exchanger is presented. The passive intensification was obtained by a modification of the heat transfer surface. The roughness of surface was increased by a use of glass micro-beads. Single-phase convective heat transfer in the water-water system was studied. The experiment was accomplished in two stages....
-
Thermodynamic and geometrical characteristics of mixed convection heat transfer in the shell and coil tube heat exchanger with baffles
PublicationThe article presents passive heat transfer enhancement method in the form of baffles to increase the energy efficiency of the shell coil heat exchanger. Conducted literature review shows that, despite numer- ous studies, there is little work on the intensification of heat transfer at the shell side. Most of the work focuses on the impact of geometrical parameters of the coil itself. This article successfully proves that it is possible...
-
Effect of surface roughness on thermal-hydraulic characteristics of plate heat exchanger
PublicationIn the paper the experimental analysis of passive heat transfer intensification in the case of modeled plate heat exchanger is conducted. The plate heat exchanger is chosen for the analysis because this kind of heat exchangers could be prospectively applied in the ORC systems, however other areas or application are equally possible. The experimental setup was assembled at the Department of Energy and Industrial Apparatus of Gdansk...
-
Ionic Liquid Assisted Dissolution of Dissolved Organic Matter and PAHs from Soil Below the Critical Micelle Concentration
PublicationIncreased use and production of ionic liquids (ILs) may result in emissions into the environment. Particularly vulnerable are industrial areas and landfills where ILs are utilized and ultimately disposed of. This study investigates how IL contamination can affect soil properties and the sorption of pre-existing contaminants. The commonly used IL 1-methyl-3-octyl imidazolium chloride ([OMIM][Cl]) was added at various quantities...
-
The effect of pre-hydrogen charging on corrosion behaviour of superduplex stainless steel welded joints
PublicationThe paper presents results of research undertaken to determine the influence of hydrogen on passivity and corrosion resistance of 2507 super duplex stainless steel welded joints. Butt welded joints were made with low heat input using flux corded arc welding (FCAW) method. Coupons of 5.0 x 5.0 mm were cut from the welded joints containing weld metal (WM), heat affected zone (HAZ) and parent metal (PM). Hydrogen was introduced...
-
Flux
Journals -
Experimental investigations on heat transfer enhancement in shell coil heat exchanger with VARIABLE Baffles GEOMETRY
PublicationThe paper presents the possibility of using passive intensification of heat transfer in the form of baffles to increase the energy efficiency of the shell and coil heat exchanger. The experiment was carried out by using a modular coil heat exchanger in the form of an electric heater. Water was used as a working fluid with constant thermal-flow parameters at the inlet of the module. It should be noted that experiments were made...
-
Inspection of Gas Pipelines Using Magnetic Flux Leakage Technology
PublicationMagnetic non-destructive testing methods can be classified into the earliest methods developed for assessment of steel constructions. One of them is the magnetic flux leakage technology. A measurement of the magnetic flux leakage is quite commonly used for examination of large objects such as tanks and pipelines. Construction of a magnetic flux leakage tool is relatively simple, but a quantitative analysis of recorded data is a...
-
Dynamics of Field Line Mappings in Magnetic Flux Tubes
PublicationWe study the topological constraints on the dynamics of magnetic field lines in flux tubes. Our approach is based on the application of the topological invariant: fixed point index. We consider periodic flux tubes and find various restrictions on the field lines that come from the sequence of fixed point indices of iterations. We also analyze the case of a tube with a cylindrical obstacle, deducing some special dynamical properties...