Search results for: RESISTIVE GAS SENSORS - Bridge of Knowledge

Search

Search results for: RESISTIVE GAS SENSORS

Search results for: RESISTIVE GAS SENSORS

  • Efficiency of gas mixtures detection by resistive gas sensors

    Publication

    - Year 2014

    Resistive gas sensors are very popular and are commonly used to detect various gases and their mixtures. Theeir main disadvantage is very limited selectivity. Practical use of gas sensors in environenmental applications requires determination of concentration of a few mixed gases at the same time. We would like to present recent results of gas detection improvement by utilizing a single gas sensor and additional measurements to...

  • EFFICIENCY OF GAS MIXTURES DETECTION BY RESISTIVE GAS SENSORS

    Publication

    - Year 2014

    Resistive gas sensors are very popular and are commonly used to detect various gases and their mixtures. Their main disadvantage is very limited selectivity. Practical use of gas sensors in environmental applications (e.g., in sewage systems to protect workers, in air conditioning systems to monitor atmosphere quality) requires determination of concentration of a few mixed gases at the same time. We would like to present recent...

  • Exhaled breath analysis by resistive gas sensors

    Breath analysis has attracted human beings for centuries. It was one of the simplest methods to detect various diseases by using human smell sense only. Advances in technology enable to use more reliable and standardized methods, based on different gas sensing systems. Breath analysis requires the detection of volatile organic compounds (VOCs) of the concentrations below individual ppm (parts per million). Therefore, advanced detection...

    Full text available to download

  • Resistive gas sensors – Perspectives on selectivity and sensitivity improvement

    Publication
    • J. Smulko
    • M. Trawka
    • U. Cindemir
    • C. G. Granqvist
    • C. Duran

    - Year 2016

    Resistive gas sensors are very popular and relatively inexpensive; they can operate at elevated or room temperature for years on end. The main disadvantage of resistive gas sensors is their limited selectivity and sensitivity, but various methods have been applied to improve their behavior. The composition of the porous gas sensing layer, or changes in the sensor’s operating temperature, can enhance the gas detection ability. Furthermore, emerging...

  • Analytical fluctuation enhanced sensing by resistive gas sensors

    Publication
    • R. Macku
    • J. Smulko
    • P. Koktavy
    • M. Trawka
    • P. Sedlak

    - SENSORS AND ACTUATORS B-CHEMICAL - Year 2015

    Resistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...

    Full text to download in external service

  • Gas selectivity enhancement by sampling-and-hold method in resistive gas sensors

    Publication

    Commercial resistive gas sensors exhibit various sensitivity to numerous gases when working at different elevated temperatures. That effect is due to a change in velocity of adsorption and desorption processes which can be modulated by temperature. Thus, to reach better selectivity of gas detection, we propose to apply a known method (called the sampling-and-hold method) of cooling down the gas sensor in the presence of the investigated...

    Full text available to download

  • New approaches for improving selectivity and sensitivity of resistive gas sensors: A review

    Publication
    • J. Smulko
    • M. Trawka
    • L. Hasse
    • C. G. Granqvist
    • R. Ionescu
    • F. E. Annanouch
    • E. Llobet
    • L. B. Kish

    - Year 2014

    Resistive gas sensors are very popular and reliable but suffer from low selectivity and sensitivity. Various methods have been suggested to improve both features without increasing the number of sensors in gas detection systems. Fluctuation enhanced gas sensing was proposed to improve gas detection efficiency by analyzing low-frequency resistance fluctuations, and noise parameters can be more informative than the single DC resistance...

    Full text to download in external service

  • New approaches for improving selectivity and sensitivity of resistive gas sensors: a review

    Publication
    • J. Smulko
    • M. Trawka
    • C. G. Granqvist
    • R. Ionescu
    • F. E. Annanouch
    • E. Llobet
    • L. B. Kish

    - Sensor Review - Year 2015

    Purpose – This paper aims to present the methods of improving selectivity and sensitivity of resistance gas sensors. Design/methodology/approach – This paper compares various methods of improving gas sensing by temperature modulation, UV irradiation or fluctuation-enhanced sensing. The authors analyze low-frequency resistance fluctuations in commercial Taguchi gas sensors and the recently developed tungsten trioxide (WO3) gas-sensing...

    Full text available to download

  • Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing

    Publication

    - SENSORS - Year 2024

    We discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...

    Full text available to download

  • Gas Detection Using Resistive Gas Sensors And Radial Basis Function Neural Networks

    Publication

    - Year 2016

    We present a use of Radial Basis Function (RBF) neural networks and Fluctuation Enhanced Sensing (FES) method in gas detection system utilizing a prototype resistive WO3 gas sensing layer with gold nanoparticles. We investigated accuracy of gas detection for three different preprocessing methods: no preprocessing, Principal Component Analysis (PCA) and wavelet transformation. Low frequency noise voltage observed in resistive gas...

  • Energy requirements for methods improving gas detection by modulating physical properties of resistive gas sensors

    Publication
    • M. Trawka
    • M. Kotarski

    - Year 2015

    Abstract. One of the most important disadvantage of resistive gas sensors is their limited gas selectivity. Therefore, various methods modulating their physical properties are used to improve gas detection. These methods are usually limited to temperature modulation or UV light irradiation for the layers exhibiting photocatalytic effect. These methods cause increased energy consumption. In our study we consider how much energy...

    Full text to download in external service

  • Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors

    This paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...

    Full text available to download

  • Computational complexity and length of recorded data for fluctuation enhanced sensing method in resistive gas sensors

    Publication

    - Year 2015

    This paper considers complexity and accuracy of data processing for gas detection using resistance fluctuation data observed in resistance gas sensors. A few selected methods were considered (Principal Component Analysis – PCA, Support Vector Machine – SVM). Functions like power spectral density or histogram were used to create input data vector for these algorithms from the observed resistance fluctuations. The presented considerations...

    Full text to download in external service

  • Simple Measurement Method for Resistive Sensors Based on ADCs of Microcontrollers

    Publication

    A new, complete measurement method for resistance measurement of resistive sensors for systems based on microcontrollers equipped with analog-to-digital converters (ADCs) is proposed. The interface circuit consists of only four resistors, including a resistive sensor and a reference resistor, connected directly to the microcontroller pins. It is activated only during measurements, which significantly reduces power consumption....

    Full text to download in external service

  • On the sensitivity, selectivity, sensory information and optimalsize of resistive chemical sensors

    Publication
    • L. B. Kish
    • J. Smulko
    • P. Heszler
    • C. G. Granqvist

    - Nanotechnology Perceptions - Year 2007

    Wykorzystano pojęcia teorii informacji do określenia możliwości poprawy selektywności i czujności rezystancyjnych sensorów gazu. Podano ogólne rozważania dotyczące limitu selektywnoœci dla tych sensorów. Porównano iloraz sygnału do szumów oraz pojemność kanału informacyjnego dla sensorów chemicznych wykorzystujących jako sygnał zjawiska fluktuacyjne z klasycznymi sensorami charakteryzowanymi jedną wartością. Ogólne rozważania wsparto...

    Full text to download in external service

  • Identification of defected sensors in an array of amperometric gas sensors

    Purpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...

    Full text to download in external service

  • Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors

    In this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...

    Full text to download in external service

  • Selectivity of amperometric gas sensors in multicomponent gas mixtures

    Publication

    In recent years smog and poor air quality became a growing environmental problem. There is a need to continuously monitor the quality of air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, a selectivity of the six amperometric gas sensors is being investigated. Calibration of sensors has been performed in order to find a correlation between concentration...

    Full text available to download

  • Gas sampling system for matrix of semiconductor gas sensors

    Semiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...

    Full text available to download

  • Problems of gas detection by resistance fluctuations in gas sensors

    Publication

    - Year 2005

    Przedstawiono problemy budowy dystrybutora gazów oraz próbek zapachowych do badań sensorów gazu. Podano układ elektroniczny wykorzystywany do rejestracji fluktuacji rezystancji obserwowany w czujnikach gazu. Załączono przykładowe wyniki obserwacji sygnałów losowych.