displaying 1000 best results Help
Search results for: SHORT-PULSE EQUATION
-
Directed electromagnetic pulse dynamics: projecting operators method
PublicationIn this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Directed pulse dynamics
PublicationIntroducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublicationThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account
PublicationWe present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...
-
Zastosowanie wyłącznika bezpiecznikowego do formowania impulsu wielkiej mocy
PublicationW wielu układach fizycznych i technicznych konieczne jest wytwarzanie impulsów wielkiej mocy o krótkim czasie trwania (rzędu ułamków µs). Impulsy te uzyskuje się stosując układy formujące zasilane ze źródła impulsowego wielkiej mocy, o długim czasie trwania impulsu, rzędu kilkudziesięciu µs. Jednym z układów formujących jest bezpiecznik wyłącznikowy. W pracy metodą symulacyjną badano wpływ parametrów bezpiecznika wyłącznikowego...
-
The generalized Suzuki model of the multipath fading channel
Open Research DataThe dataset contains the results of simulations that are part of the research on modelling the multipath fading in the communication channel. The generalized Suzuki fading envelope is generated using the Monte-Carlo simulation (MCS) in the LabVIEW programming environment.
-
Estimating Intercept Range of Silent Sonar
PublicationWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
Projecting procedure for meta-material fiber
PublicationWe would like to show new way of derivation evolution equation for short pulses in dielectric waveguide including one model of metamaterial waveguide. This derivation model rely on projecting to the orthogonal basis. In our case to orthogonal basis for cylindrical waveguide.
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublicationThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Acoustic heating produced in the thermoviscous flow of a bingham plastic
PublicationThis study is devoted to the instantaneous acoustic heating of a Bingham plastic. The model of the Bingham plastic's viscous stress tensor includes the yield stress along with the shear viscosity, which differentiates a Bingham plastic from a viscous Newtonian fluid. A special linear combination of the conservation equations in differential form makes it possible to reduce all acoustic terms in the linear part of of the final equation...
-
Acoustic heating produced in the thermoviscous flow of a Bingham plastic
PublicationThis study is devoted to the instantaneous acoustic heating of a Bingham plastic. The model of the Bingham plastic's viscous stress tensor includes the yield stress along with the shear viscosity, which differentiates a Bingham plastic from a viscous Newtonian fluid. A special linear combination of the conservation equations in differential form makes it possible to reduce all acoustic terms in the linear part of of the final equation...
-
Samotestowanie toru analogowego ze wzmacniaczem w pełni różnicowym w elektronicznych systemach wbudowanych sterowanych mikrokontrole-rami
PublicationPrzedstawiono nową metodę samotestowania toru analogowego opartego na wzmacniaczu w pełni różnicowym w elektronicznych systemach wbu-dowanych sterowanych mikrokontrolerami. Bazuje ona na nowej metodzie diagnostycznej opartej na przekształceniu transformującym próbki odpo-wiedzi czasowej badanej części analogowej na pobudzenie "ujemnym" impulsem prostokątnym na wejściu Vocm na krzywe identyfikacyjne w przestrzeni pomiarowej. Metoda...
-
Residence time distribution in rapid multiphase reactors
PublicationResidence time distribution (RTD) provides information about average hydraulic residence time and the distribution of material in the reactor. A method for determining RTD for reactors with very short hydraulic residence times is deconvolution based on extraction of real RTD by the analysis of a non-ideal input signal. The mean residence time and dispersion were determined for the spinning fluids reactor (SFR). For the first time...
-
Cross-talk Between the Heart and Arteries in Older 65+ Adults
PublicationRegulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublicationAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
The Suzuki model of the multipath fading channel
Open Research DataThe dataset contains the results of simulations that are part of the research on modelling the multipath fading in the communication channel. The Suzuki fading envelope is generated using the Monte-Carlo simulation (MCS) in the LabVIEW programming environment.
-
Reliable underwater communication system for shallow coastal waters
PublicationThis paper presents a reliable and robust low data rate spread spectrum approach which is implemented in the acoustic underwater communication system for shallow coastal waters. It shows operation assumptions of spread spectrum techniques based on the wellknown Shannon equation. It describes two methods of spread spectrum: frequency hopping spread spectrum and direct sequence spread spectrum; their block diagram and their characteristics...
-
Modeling the impact of rotor movement on non-linearity of motor currents waveforms in high-speed PMSM drives
PublicationMotor current measurement techniques as well as predictive control algorithms for electric drives rely on an assumption of linear motor currents changes resulting from constant inverter output voltages. Recent research has reported that this assumption does not hold in motors with short electrical time constant, and in drives whose rotor position advances substantially during a control period. This paper proposes a simulation model...